Poly PE Insulated ABC Cable with Aluminium Conductor AAC AAAC ACSR

Poly PE Insulated ABC Cable with Aluminium Conductor AAC AAAC ACSR

Poly PE Insulated ABC Cable with Aluminium Conductor AAC AAAC ACSR

ABC

Jinyuan

ISO9001, CE, CCC, RoHS

Oveahead

Round Wire

XLPE

No

Aluminum

Overhead, Underground

Stranded

Insulated

LV. Mv. Hv

as Per Your Customers ' Request

PVC/PE/XLPE

Jinyuan

All Wooden, Steel Wooden or Steel Package

China

8544492100

Product Description

poly PE INSULATED ABC CABLE with ALUMINIUM CONDUCTOR aac aaac acsr
 ABC Cable

Aluminum Conductor XLPE Insulated ABC Electric Cable
We produce the ABC Electric Cable used for overhead line(duplex, triplex, quadruplex) in IEC standard, ASTM, BS, NF C 33-209 standard.

LV ABC cable(Aerial Bundle cable) with AAAC conductor

Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, Duplex, Triplex, Quadruplex.

Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.

Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:

Duplex Service Drop

Triplex Service Drop

Quadruplex Service Drop

The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.

 Detaild Introduction of Service Drop Cable
1  Duplex Service Drop
Applications: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.

Construction: Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

2 Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.

Construction: Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

 3 Quadruplex Service Drop
Applications: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Construction: Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.
 
Product Description
1.Application:
Pvc insulated abc cable as a new-type aerial cable is used for transmitting electric power overhead, extensively used in rebuilding of urban and forest region electrified wire netting. It improves the safety and reliance of electrified wire netting.

2.Specification:
Concentric strand aluminum wires as phase conductor; AAAC(all aluminum alloy conductors) or ACSR(aluminum conductor steel reinforced) as messenger (Neutral) core; Phase conductor is insulated by XLPE or HDPE or PVC.

3.Standards:
IEC60502, NF C33-209, GB 12527-90
Rated voltage: 0.6/1kV
Relative manufacturing standards: IEC61089, ASTM B231, ASTM B232, BS215, DIN48201, DIN48204.

4.It meets or exceeds the following specifications:
1. Aluminum Wire, 1350-H19 for Electrical Purposes.
2. Aluminum Conductors, Concentric-Lay-Stranded.
3. Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. Concentric-Lay-Stranded 6201-T81 Conductors.
5. Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
It meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
5.Construction & descriptions:

specifications      
 (mm2)                    
specifications      
 (mm2) 
specifications      
 (mm2)
 
specifications      
 (mm2)  
1×10 1×120+120 2×50+50 3×10+10
1×16 1×150+150 2×70+70 3×16+16
1×25 1×185+185 2×95+95 3×25+25
1×35 1×240+240 2×120+120 3×35+35
1×50 1×16+16(Bare) 2×150+150 3×50+50
1×70 1×25+25(Bare) 2×185+185 3×70+70
1×95 1×35+35(Bare) 2×240+240 3×95+95
1×120 1×50+50(Bare) 2×10+10(Bare) 3×120+120
1×150 1×70+70(Bare) 2×16+16(Bare) 3×150+150
1×185 1×95+95(Bare) 2×25+25(Bare) 3×185+185
1×240 1×120+120(Bare) 2×35+35(Bare) 3×240+240
1×10+10 1×150+150(Bare) 2×50+50(Bare) 3×16+16(Bare)
1×16+16 1×185+185(Bare) 2×70+70(Bare) 3×25+25(Bare)
1×25+25 1×240+240(Bare) 2×95+95(Bare) 3×35+35(Bare)
1×35+35 2×10+10 2×120+120(Bare) 3×50+50(Bare)
1×50+50 2×16+16 2×150+150(Bare) 3×70+70(Bare)
1×70+70 2×25+25 2×185+185(Bare)  
1×95+95 2×35+35 2×240+240(Bare)  

Duplex Service Drop

Code
word
AWG or kcmil Bare Neutral Messenger Phase conductor Weight
Kg/km
Allowcable
Ampacities(A)
ACSR Rated
Strength
Lbs.
AAC Insul
Thick.mm
XLPE PE
Number Dia.
mm
Number Dia.mm Number Dia.mm
Setter
Shepherd
Eskimo
Terrier
Chow
Bull
1*6AWG+1*6AWG
1*6AWG+1*6AWG
1*4AWG+1*4AWG
1*4AWG+1*4AWG
1*2AWG+1*2AWG
1*1/0AWG+1*1/0AWG
1
1
1
1
1
1
1.68
1.68
2.12
2.12
2.67
3.37
6
6
6
6
6
6
1.68
1.68
2.12
2.12
2.67
3.37
1190
1190
1860
1860
2850
4380
1
7
1
7
7
19
4.11
1.56
5.19
1.96
2.47
1.89
1.14
1.14
1.14
1.14
1.14
1.52
111
113
171
173
266
427
85
85
115
115
150
205
70
70
90
90
120
160

Triplex ABC Cable

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per 1000 ft.(lbs.) Allo wable Amp acitles
Size (A WG) Stranding Insul Thick(Mils) Size (AWG) Stranding Rated Strength (lbs.) inches XLP POLY XLP POLY
AAC Neutral-messenger
Pateela 6 7 45 6 7 563 14.88 103 103 85 70
Oyster 4 7 45 4 7 881 14.88 154 154 115 90
Clam 2 7 45 2 7 1350 20.58 233 233 150 120
Murex 1/0 7 60 1/0 7 1990 20.58 374 374 205 160
Purpura 1/0 9 60 1/0 7 1990 20.58 368 368 205 160
Nassa 2/0 7 60 2/0 7 2510 25.42 462 462 235 185
Melita 3/0 17 60 3/0 19 3310 29.97 562 562 275 215
Portunus 4/0 18 60 4/0 19 4020 29.97 696 696 315 245
Nannynose 336.4 19 60 336.4 19 6146 38.79 1118 1118 420 325
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP) +Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun.

QuadruplexABC Cable

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per 1000 ft.(lbs.) Allo wable Amp acitles
Size (A WG) Stranding Insul Thick(Mils) Size (AWG) Stranding Rated Strength (lbs.) inches XLP POLY XLP POLY
AAC Neutral-messenger
Clydessdale 4 1 45 4 7 881 20.58 198 198 100 80
Pinto 4 7 45 4 7 881 20.58 211 211 100 80
Mustang 2 7 45 2 7 1350 25.42 318 318 135 105
Criollo 1/0 9 60 1/0 7 1990 25.42 503 503 180 140
Percheron 2/0 11 60 2/0 7 2510 29.97 619 619 205 160
Hanovarian 3/0 17 60 3/0 19 3310 35.18 764 764 235 185
Oldenburg 4/0 18 60 4/0 19 4020 35.18 945 945 275 210
Lippizaner 336.4 19 80 336.4 19 6146 38.79 1519 1519 370 280
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP) +Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.

Why Choose us?  
For over 20 years, Jinyuan Cable INC., which is as a professional cable manufacturer has been producing customized cable for a wide range of applications based on high quality, excellent service and competitive market prices. This is an elite team with experienced personnel and strong technical support. Our achievements benefit by having access to the largest market for cheap labor and abundant resources in China and our determination to exceed our clients’ expectations.

Tags: , ,