Plant Used Electric Power Cable Sizes

Plant Used Electric Power Cable Sizes

Plant Used Electric Power Cable Sizes

Power Cable

Rmjt

ISO9001, CE, CCC

Flame Retardant

Round Wire

PVC

PVC

Copper

Overhead, Heating, Underground

Stranded

Insulated

600/1000V XLPE/PVC Insulation Power Cable 

Manufacturer

1, 2, 3, 4, 5, 2+1, 3+2 or as Your Demand

0.6/1kv; 8.7/15kv; 12/20kv; 21/35kv; 26/35kv

VV, Vlv, Yjv, Yjlv, Yjv22, Yjlv22, Yjv32, Yjlv32..

GB-T12706-2008; IEC 60502

Wooden Drum, Steel Drum or as Your Requirement

Professional Manufacturer of 25 Years in China

High Quality, Competitive Price, Fast Delivery

RMJT

Wooden/Steel Drum

1.5mm2-800mm2

Henan, China

8544492100

Product Description

600/1000V XLPE/PVC Insulation Power Cable 

Characteristics of Cable
1.Max Long-time operating temperature of PVC insulated cable is 70°C,XLPE 90°C
2.Installing temperature of cable should not be less than 0°C
3.Max short-circuit temperature is:PVC not exceed 160°C,XLPE 250°C,Not more than5 Sec.
4.Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable)
5.Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant
 

1Core  
(sqmm)
2Core 
(sqmm)
3core 
(sqmm)
3c+1c  
(sqmm)
4core   
 (sqmm)
3c+2c 
 (sqmm)
4c+1c    
(sqmm)
5core 
 (sqmm)
1×1.5 2×1.5 3×1.5 3×2.5+1×1.5 4×1.5 3×2.5+2×1.5 43×2.5+1×1.5 5×1.5
1×2.5 2×2.5 3×2.5 3×4+1×2.5 4×2.5 3×4+2×2.5 4×4+1×2.5 5×2.5
1×4 2×4 3×4 3×6+1×4 4×4 3×6+2×4 4×6+1×4 5×4
1×6 2×6 3×6 3×10+1×6 4×6 3×10+2×6 4×10+1×6 5×6
1×10 2×10 3×10 3×16+1×6 4×10 3×16+2×6 4×16+1×6 5×10
1×16 2×16 3×16 3×25+1×10 4×16 3×25+2×10 4×25+1×10 5×16
1×25 2×25 3×25 3×35+1×10 4×25 3×35+2×10 4×35+1×10 5×25
1×35 2×35 3×35 3×50+1×16 4×35 3×50+2×16 4×50+1×16 5×35
1×50 2×50 3×50 3×70+1×25 4×50 3×70+2×25 4×70+1×25 5×50
1×70 2×70 3×70 3×95+1×35 4×70 3×95+2×35 4×95+1×35 5×70
1×95 2×95 3×95 3×120+1×35 4×95 3×120+2×35 4×120+1×35 5×95
1×120 2×120 3×120 3×150+1×50 4×120 3×150+2×50 4×150+1×50 5×120
1×150 2×150 3×150 3×185+1×50 4×150 3×185+2×50 4×185+1×50 5×150
1×185 2×185 3×185 3×240+1×70 4×185 3×240+2×70 4×240+1×70 5×185
1×240 2×240 3×240 3×300+1×95 4×240 3×300+2×95 4×300+1×95
1×300 2×300 3×300 3×400+1×150 4×300 3×400+2×150 4×400+1×150
1×400 2×400 3×400 4×400 – 
Cross Section of Conductor No. of Wires Thickness of Insulation Thickness of Inner Sheath Thickness of Steel Tape No./Dia. Of Steel Wires Thickness of Sheath Overall Diameter Approx. Net Weight
STA SWA
STA SWA STA SWA STA SWA Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm No./mm mm mm mm mm kg/km kg/km kg/km kg/km
Three Cores
3×35 16 1.2 1 0.2 38/1.6 1.8 1.9 24.7 28.2 912 1591 1447 2126
3×50 18 1.4 1 0.2 46/1.6 1.9 2 29.3 32.8 1202 2105 1842 2745
3×70 18 1.4 1.2 0.2 41/2.0 2.0 2.2 32.5 37.1 1520 2820 2475 3775
3×95 36 1.6 1.2 0.5 46/2.0 2.1 2.3 36.5 40.8 2241 4049 2989 4797
3×120 36 1.6 1.2 0.5 50/2.0 2.2 2.4 39.8 44.1 2617 4895 3435 5713
3×150 36 1.8 1.2 0.5 43/2.5 2.3 2.5 42.4 47.8 3019 5846 4258 7085
3×185 36 2 1.4 0.5 50/2.5 2.5 2.7 48.8 54.2 3783 7264 5219 8700
3×240 60 2.2 1.6 0.5 58/2.5 2.8 2.9 56 61.3 4790 9390 6444 11044
3×300 60 2.4 1.6 0.5 61/2.5 2.9 3.1 59.3 64.7 5594 11345 7458 13209
Four Cores with Reduced Neutral
3×35+16 16-7 1.2-1 1 0.2 43/1.6 1.9 2 28.5 31.3 1107 1528 1705 2469
3×50+25 18-16 1.4-1.2 1.2 0.2 40/2.0 2.0 2.1 32.2 36.1 1410 2044 2326 3388
3×70+35 18-16 1.4-1.2 1.2 0.2 44/2.0 2.0 2.2 35.2 39.3 1733 2801 2762 4285
3×95+50 36-18 1.6-1.4 1.2 0.5 41/2.5 2.3 2.5 42.5 46.3 2656 3820 3816 5925
3×120+70 36-18 1.6-1.4 1.4 0.5 45/2.5 2.4 2.6 45.6 49.4 3137 4777 4391 7103
3×150+70 36-18 1.8-1.4 1.4 0.5 49/2.5 2.6 2.7 49.9 53.6 3660 5709 5043 8272
3×185+95 36-36 2-1.6 1.4 0.5 55/2.5 2.6 2.9 54.5 58.5 3445 7171 5902 9987
3×240+120 60-36 2.2-1.6 1.6 0.5 62/2.5 2.9 3.1 61.6 65.3 5441 9272 7174 12552
3×300+150 60-36 1.4-1.8 1.6 0.5 67/2.5 3.8 3.2 65.9 69.6 6494 11546 8355 15067
Four Cores
4×25 16 1.2 1 0.2 38/1.6 1.8 1.9 25.3 28 934 1576 1450 2092
4×35 16 1.2 1 0.2 41/1.6 1.8 1.9 27.4 30.2 1120 2017 1681 2578
4×50 18 1.4 1 0.2 39/2.0 2 2.1 31.6 35.6 1454 2658 2336 3540
4×70 18 1.4 1.2 0.5 43/2.0 2.1 2.2 36.3 39 2183 3916 2840 4573
4×95 36 1.6 1.2 0.5 50/2.0 2.3 2.4 40.6 44.1 2748 5160 3545 5957
4×120 36 1.6 1.4 0.5 42/2.5 2.4 2.5 43.9 47.2 3237 6214 4334 7372
4×150 36 1.8 1.4 0.5 48/2.5 2.5 2.6 48.3 52 3853 7622 5148 8917
4×185 36 2 1.6 0.5 54/2.5 2.7 2.8 54.3 57.6 4756 9323 6132 10774
4×240 60 2.2 1.6 0.5 59/2.5 2.9 3 59.2 62.9 5774 11906 7374 13506
4×300 60 2.4 1.6 0.5 65/2.5 3 3.2 64.3 68.1 6922 14589 8624 16291

 
Product Pictures:

Packing and Delivery:

Our Company:
People’s Cable Group Co., Ltd, a professional wires and cables manufacturer for 27 years in China. we mainly produce power cables, control cables, aerial overhead cables(ABC, AAC ACSR and AAAC cables) etc. Standards Supported: ASTM, BS, CSA, IEC, DIN and GB etc.
1. Factory: 160000 square meters, available for OEM;
2. Lead time: 5-7 working days after payment received;
3. Authentication: TUV, OHSAS, CCC,  ISO9001:2008;
4. Guarantee: 20 years;
5. QC inspection: Strict inspection before delivery;
After-sales Service:
1. All our cables will be tested well in production and before delivery.
2. Please contact us if any problem, we will respond within 24 hours.

FAQ:
(1)When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
(2)How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
(3)How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files,  the samples will be ready for delivery in 3-7days. The samples will be sent to you via express and arrive in 3-5 days. You can use your own express account or prepay us if you do not have an account.
(4)What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country. 

Contact Information:
Ivan Fan | Sales Manager | People’s Cable Group
 
T: 86-371-55367868 | M: 86-15637878931
Fax: 86-371-55367868 
Web: www.vwcable.com 

If you have any questions, please contact me, I will reply you as soon as possible.
Welcome your inquiry.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.