Overhead XLPE Insulated Aluminum Cable ABC Bundled Cable

Overhead XLPE Insulated Aluminum Cable ABC Bundled Cable

Overhead XLPE Insulated Aluminum Cable ABC Bundled Cable

AWG 1/0, 2/0, 3/0, 4/0

Phase Insulated with Bare Neutral

Solid or Stranded

Overhead

Aluminum or Aluminum Alloy or Aluminum & Steel

None

PE or XLPE

Round Wire

Refractory

ISO9001, CCC, RoHS, VDE

Jytop

Dupliex Cable

Covered Line Wire

ASTM, AS/NZS, BS, CSA, DIN, IEC…

Ce, ISO 9001

JYTOP

Packed in Reels

as per related ASTM standards

Zhengzhou, China

8544492100

Product Description

Overhead Xlpe Insulated Aluminum Cable ABC bundled cable

Duplex cable, triplex cable,quadruplex cable (duple service drop cable, triplex service drop cable, Quadruplex service drop cable) meets or exceeds the requirements of all international standards like ASTM,IEC,DIN,BS,AS,CSA,NFC,SS,etc. in addition, we also accept OEM service to meet your special request.

Construction:

Three insulated phase conductors twisted around a bare aluminum alloy or ACSR neutral conductor.

Conductors: Aluminum alloy 1350-H19 wire.

Insulation: Black thermoset cross-linked polyethylene (XLPE).

Neutral: Bare aluminum alloy or ACSR.

Duplex , triplex ,Quadruplex service drop cable-aluminum conductor (600V)

Phase
Conductor
stranded aluminum wires (AAC)
Insulation black thermosetting cross-linked polyethylene (XLPE)
thermoplastic low density polyethylene (LDPE)
thermoplastic high density polyethylene (HDPE)
Neutral stranded aluminum wires (AAC)
stranded aluminum alloy wires (AAAC)
stranded aluminum conductor steel reinforced (ACSR)

Application:

This quadruplex cable is suited for use as drop cable from a pole mounted transformer to the service entrance of a structure, or as secondary distribution between poles. The cable should be limited to 600V phase to phase and not exceed 90C.

Parameter of Aluminium conductor XLPE insualted ABC cable

Code
name
Phase conductor Bare neutral messenger Weight per
1000 ft(lbs)
Rating(Amps)
Size
AWG
Strand Insulation
thickness
(mls)
Size
AWG
Strand Breaking
strength
(lbs)
XLP POLY XLP POLY
AAC NEUTRAL-MESSNGER
Clydesdale 4 Solid 45 4 7 881 208 201.8 100 80
Pinto 4 7/w 45 4 7 881 223 207.9 100 80
Mustang 2 7/w 45 2 7 1,350 333 312.6 135 105
Criollo 1/0 19/w 60 1/0 7 1,990 529 504.5 180 140
Percheron 2/0 19/w 60 2/0 7 2,510 649 620.5 205 160
Hanoverian 3/0 19/w 60 3/0 19 3,310 799 765.6 235 185
Oldenburg 4/0 19/w 60 4/0 19 4,020 986 946.7 275 210
Lippizaner 336.4 19/w 80 336.4 19 6,146 1,546 1,519.2 370 280
ACSR NEUTRAL-MESSNGER
Morochuca 6 Solid 45 6 6/1 1,190 152 147.4 75 60
Chola 6 7/w 45 6 6/1 1,190 162 151.7 75 60
Morgan 4 Solid 45 4 6/1 1,860 226 220 100 80
Hackney 4 7/w 45 4 6/1 1,860 241 226.1 100 80
Palomino 2 7/w 45 2 6/1 2,850 362 342.6 135 105
Costena 1/0 19/w 60 1/0 6/1 4,380 575 550.6 180 140
Grullo 2/0 19/w 60 2/0 6/1 5,310 707 678.7 205 160
Suffolk 3/0 19/w 60 3/0 6/1 6,620 872 838.9 235 185
Appaloosa 4/0 19/w 60 4/0 6/1 8,350 1079 1039.2 275 210
Bronco 336.4 19/w 80 336.4 18/1 8,580 1613 1568.2 370 280
Gelding 336.4 19/w 80 4/0 6/1 8,350 1548 1494.3 370 280
Code
name
Phase conductor Bare neutral messenger Weight per
1000 ft(lbs)
Rating(Amps)
Size
AWG
Strand Insulation
thickness
(mls)
Size
AWG
Strand Breaking
strength
(lbs)
XLP POLY XLP POLY
6201 ALLOY NEUTRAL-MESSENGER
Bay 6 Solid 45 6 7 1,110 145 140.0 75 60
French Coach 6 7/w 45 6 7 1,110 155 144.3 75 60
German Coach 4 Solid 45 4 7 1,760 214 208.3 100 80
Arabian 4 7/w 45 4 7 1,760 229 214.4 100 80
Belgian 2 7/w 45 2 7 2,800 344 323.1 135 105
Shetland 1/0 19/w 60 1/0 7 4,460 546 521.1 180 140
Thoroughbred 2/0 19/w 60 2/0 7 5,390 670 641.5 205 160
Trotter 3/0 19/w 60 3/0 7 6,790 825 791.8 235 185
Walking 4/0 19/w 60 4/0 7 8,560 1019 979.7 275 210