Overhead Stranded Conductor ABC Cable with AAC ACSR AAAC Neutral Message

Overhead Stranded Conductor ABC Cable with AAC ACSR AAAC Neutral Message

Overhead Stranded Conductor ABC Cable with AAC ACSR AAAC Neutral Message

ABC cable

Construction, Overhead, Power Station, Telecommunication

Low and Medium Voltage Cable

DC & AC

XLPE

No Sheath

Round Wire

Aluminum Conductor

ISO, CCC, CE, VDE

SGS

ABC Cable

Jinshui

Aluminum

XLPE, PE

Black

Twisted

JINSHUI

Wooden Drum

2*16, 2*25, 2*50, 3*50, 3*95, 4*16, 4*25, 4*35

Henan

8544492100

Product Description

Overhead stranded conductor ABC cable with AAC ACSR AAAC Neutral Message
1. Application of Service Drop Cable
Service Drop Cable(ABC CABLE) are mainly used for electric power tranmission, rebuilding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
2.Types of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop Triplex Service Drop Quadruplex Service Drop
2.1 Duplex Service Drop
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
2.2 Triplex Service Drop
Applications
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
2.3 Quadruplex Service Drop
Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

Item Phase Conductor

Size AWG

Phase

Conductor

Stranding

Phase Conductor

Insulation Thickness

Bare Neutral

Messenger

Size AWG

Bare

Neutral Strand

Bare Neutral messenger Breaking Strength Weight Per 1000ft – XLP Weight Per 1000ft – Poly Rating – XLP Rating-Poly
Pekingese 6 Solid 45 mls 6 7/w 563 Lbs 63.5 Lbs 61.7 Lbs 70 Amps 70 Amps
Collie 6 7/w 45 mls 6 7/w 563 Lbs 66.8 Lbs 63.1 Lbs 70 Amps 70 Amps
Dachshund 4 Solid 45 mls 4 7/w 881 Lbs 95.5 Lbs 93.4 Lbs 90 Amps 90 Amps
Spaniel 4 7/w 45 mls 4 7/w 881 Lbs 100.5 Lbs 95.4 Lbs 90 Amps 90 Amps
Doberman 2 7/w 45 mls 2 7/w 1350 Lbs 152.7 Lbs 145.7 Lbs 120 Amps 120 Amps
Malemute 1/0 19/w 60 mls 1/0 7/w 1990 Lbs 242.6 Lbs 234.2 Lbs 160 Amps 160 Amps