Overhead Messenger Cable AAC Conductor

Overhead Messenger Cable AAC Conductor

Overhead Messenger Cable AAC Conductor

AAC

Bare

Stranded

Overhead

Aluminum

Bare

ISO9001, CE, CCC

Single

ACSR

Jinshui

Wooden Drums or Steel-Wooden Drums

CE, ISO, CCC

Zhengzhou, Henan

Product Description

Applications
AAC, AAAC, ACSR, ACAR conductor have been widely used in power transmission lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost large transmission capacity. And they are also suitable for laying across rivers and valleys where special geographical features exist.
1. Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)aluminimum conductor aluminimum alloy reinforced(ACAR)
2. Standard:
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.
Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75º C conductor temperature, 25º C ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

Code Name Size
(KCM)
Strand Approx.EC Cond with Equivalent Resistance Stranding Diameter(in) Cross
Sectional
Area
(Sq in)
Weight
per 1000ft
(lbs)
Rated
Strength
(lbs)
Resistance
Ohms/1000ft (lbs)
Individual
Wires
Complete
Cable
DC @ 20 o C AC@ 75 o C
Akron 30.58 7/w 6 6/1 .0661 .198 .0240 28.7 1,110 .659 .785
Alton 48.69 7/w 4 6/1 .0834 .250 .0382 45.7 1,760 .414 .493
Ames 77.47 7/w 2 6/1 .1052 .316 .0608 72.7 2,800 .260 .310
Azusa 123.3 7/w 1/0 6/1 .1327 .398 .0968 115.7 4,460 .163 .195
Anaheim 155.4 7/w 2/0 6/1 .1490 .447 .1221 145.9 5,390 .130 .154
Amherst 195.7 7/w 3/0 6/1 .1672 .502 .1537 183.7 6,790 .103 .123
Alliance 246.9 7/w 4/0 6/1 .1878 .563 .1939 231.8 8,560 .0816 .0973
Butte 312.8 19/w 266.8 26/7 .1283 .642 .2456 293.6 11,000 .0644 .0769
Canton 394.5 19/w 336.4 26/7 .1441 .721 .3098 370.3 13,300 .0511 .0610
Cairo 465.4 19/w 397.5 26/7 .1565 .783 .3655 436.9 15,600 .0433 .0518
Darien 559.5 19/w 477.0 26/7 .1716 .858 .4394 525.5 18,800 .0360 .0431
Elgin 652.4 19/w 556.5 26/7 .1853 .927 .5124 612.4 21,900 .0309 .0371
Flint 740.8 37/w 636.0 26/7 .1415 .991 .5818 695.5 24,400 .0272 .0327
Greely 927.2 37/w 795.0 26/7 .1583 1.108 .7282 870.4 30,500 .0217 .0263

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.