Nyy/Nayy/Nycy/Nysy/Nycwy Copper Underground Electrical Power Cable

Nyy/Nayy/Nycy/Nysy/Nycwy Copper Underground Electrical Power Cable

Nyy/Nayy/Nycy/Nysy/Nycwy Copper Underground Electrical Power Cable

Nyy/Nayy/Nycy/Nycwy/Naycwy

Construction, Underground, Power Station

Low and Medium Voltage Cable

DC & AC

XLPE

PVC

Round Wire

Red Copper Wire

ISO, CCC, CE, VDE

YJLV22

Jytop

4,6,10,16,25,35,50,70,95,120mm2

Black or as Your Request

ISO, Ce,CCC

JYTOP

Drums or as Your Request

CE, CCC, ASTM. BS

Henan, Zhengzhou

8544492100

Product Description

NYY/NAYY/NYCY/NYSY/NAYCWY underground Electrical Power Cable 0.6/1 kV

1. Application
    PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.
     XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables. XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level. It can be applied in high temperature of 90 degree for a long time.
2. Standard 
  IEC 60502,  IEC60332,  IEC 60754

3. Specification
 1). Rated Voltage, No. of Core and Range of Sectional Area

Rated voltage (kv)
Sectional area (mm2)
No. of core
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 26/35
1 Core   1.5-800 25-800 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
2 Core   1.5-185 25-185            
3 Core   1.5-400 25-400 25-400 25-400 35-400 50-400 50-400 50-400
4 Core   2.5-400 25-400            
5 Core   2.5-400 25-400            

 2).  DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.

Nominal section area (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Copper core 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.099 0.0754 0.0601 0.047 0.0366 0.0283 0.0221
Aluminum core 18.1 12.1 7.41 4.61 3.08 1.91 1.2 0.868 0.641 0.443 0.32 0.253 0.206 0.164 0.125 0.1 0.778 0.0605 0.0469 0.0367

 3). Voltage Test and Partial Discharge Test

Rate voltage Uo (kv)
Item
0.6/1 1.8/3 3.6/6 6/6 6/10 8.7/10 8.7/15 12/20 18/20 18/30 21/35 26/35
Voltage Test voltage 3.5 6.5 12.5 21 30.5 42 63 73.5 91
Test time 5 5 5 5 5 5 5 5 5
Partial discharge test Test voltage 6.2 10.4 15.1 20.8 31.1 36.3 45
Discharge capacity 10 10 10 10 10 10 10

NYY/NAYY/NYCY/NYCWY/NAYCWY cable

Type Description Applications
N2XY/N2XSEY
NA2XY/NA2XSEY
Cu or AL conductor XLPE insulated PVC sheathed power cables. For laying indoors, in tunnels, in ducts. Able to bear extermal mechanical force but not large pulling forces. Single core cables are impermissible to be laid in magnetic ducts.
N2X2Y/N2XSE2Y
NA2X2Y/NA2XSE2Y
Cu or AL conductor XLPE insulated PE sheathed power cables.
N2XBY/N2XSEBY
NA2XBY/NA2XSEBY
Cu or AL conductor XLPE insulated PVC sheathed internal steel tape armoured power cables. For laying indoors, in tunnels, in ducts and underground. Able to bear extermal mechanical force but not large pulling forces, Impermissible to use single core cable in A.C circuit.
N2XB2Y/N2XSEB2Y
NA2XB2Y/NA2XSEB2Y
Cu or AL conductor XLPE insulated PE sheathed internal steel tape armoured power cables.
N2XRY/N2XSERY
NA2XRY/NA2XSERY
Cu or AL conductor XLPE insulated PVC sheathed internal steel wire armoured power cables. For laying in underground areas along route with large difference of elevation, in shafts and in water, able to bear a corresponding pulling forces and external mechanical forces.
N2XR2Y/N2XSER2Y
NA2XR2Y/NA2XSER2Y
Cu or AL conductor XLPE insulated PE sheathed internal steel wire armoured power cables.

power cable package picture :