NF C 33-209 Aerial Bundled Cable Phase Conductor Lighting Conductor AAAC Messenger

NF C 33-209 Aerial Bundled Cable Phase Conductor Lighting Conductor AAAC Messenger

NF C 33-209 Aerial Bundled Cable Phase Conductor Lighting Conductor AAAC Messenger

ABC Cable

Jinyuan

Jklv

ISO, CCC, CE, UL

Aluminium/Copper

Round Wire

None

PE

DC & AC

Low and Medium Voltage Cable

Construction, Overhead, Underground, Industrial, Power Station

PVC/PE/XLPE

40000m2

Power Distribution

HUATONG

Drum

GB/T 12527

China

8544492100

Product Description

Aluminium Service Drop
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.

ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors. 

ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR.One conductor is manufactured with an extruded ridge for phase identification.

ABC Cables Standards:
1.B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2.B-231 Aluminum conductors, Concentric-Lay-Stranded.
3.B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4.B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5.B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6.Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

ABC Cables Using Properties
1.Rated Voltage:0.6/1kV
2.Cable installation temperature not less than -20°C
3.Max. temperature of cable at short circuit(The max. duration does not exceed 5 minutes)
   For XLPE insulation is 250°C.
   For HDPE insulation is 150 °C.
4.The Max. bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1.Duplex Service Drop:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
2.Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
3.Quadruplex Service Drop: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

Code Word Phase conductor Bare Neutral Messenger Nominal Lay Length Weight Per 1000ft. (lbs.) Allowable Ampacities+
Size
(AWG)
Stranding Insul. Thick.
(Mils)
Size
(AWG)
Stranding Rated Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Pekingese 6 1 45 6 7 563 10.36 61 61 85 70
Collie 6 7 45 6 7 563 10.36 64 64 85 70
Dachshund 4 1 45 4 7 881 10.36 92 92 115 90
Spaniel 4 7 45 4 7 881 10.36 96 96 115 90
Doberman 2 7 45 2 7 1350 14.88 147 147 150 120
Malemute 1/0 9 60 1/0 7 1990 14.88 234 234