Na2xcy Medium Voltage Wire Aerial Bundled Aluminum ABC Cable

Na2xcy Medium Voltage Wire Aerial Bundled Aluminum ABC Cable

Na2xcy Medium Voltage Wire Aerial Bundled Aluminum ABC Cable

5kV, 15kV, 25kV, 35kV, 46kV

Construction, Overhead, Industrial, Telecommunication

Low and Medium Voltage Cable

AC Cable

XLPE

PVC

Round Wire

Aluminum

CE

SABS

5000km/Week

1km

Accord with The Request

SABS, ISO9001-2008, CQC Certificate, CE , SGS

Tianjin, Qingdao, Ningbo, Shanghai, Xiamen

L/C, D/P, D/a ,T/T, M/T, D/D, O/a, C.W.O, C.O.D, C

JIAPU

Wooden Drum

Single, Duplex. Triplex. Quanplex.

China

8544601200

Product Description

Na2xcy Medium Voltage wire Aerial Bundled aluminum abc cable

CONSTRUCTION:
Circular compacted stranded aluminum conductor, XLPE insulated, copper tape screened and PVC outer sheathed cable. The three XLPE insulated and copper tape screened single core cables are bundled around the galvanized steel wires in a right hand lay.
1. Conductor
Phase conductors are circular compacted stranded aluminum. The standard messenger comprises of stranded galvanized steel wires.
2. Conductor Screen
Extruded layer of semi conductive compound.
3. Insulation
Cross-linked polyethylene (XLPE) rated at 90°C.
4. Insulation Screen
4a. Non-metallic part
Extruded layer of semi conductive compound.
4b. Metallic part
Copper tape screen (SCT)
5. Color for core identification
Red, yellow and blue tapes shall be applied between nonmetallic and metallic part of insulation screen. The outer sheath shall be embossed with figures 1, 2, 3 corresponding to red, yellow, blue phase.
6. Separator
Polypropylene laminated tape.
7. Outer Sheath
PVC type ST2 to IEC 60502 color black.
8. Assembly
The three XLPE insulated and copper tape screened single core cables are bundled around the galvanized steel messenger wires in a right hand lay.

FEATURES
Triple extruded for clean interfaces
Class 10,000 environment utilized for cable core material handling
Flexibility for easy handling
Excellent moisture resistance
Deformation-resistant
High dielectric strength
Low dielectric loss
Excellent resistance to water treeing
Clean-stripping insulation shield without the use of a release agent
Sunlight-resistant

TECHNICAL DATASHEET

Condctor Copper Neutral (1/3) diameter(inch) Weight (Pounds)
AWG orMCM Stranding

Number of Wires

SizeAWG (Solid) Conductor

Over

Insulation

Over Insul.

Shield

Over Neutral

Wires

Over

Encaps. Jkt.

Conductor

Concentric

Neutral

TotalNo

Jacket

Total WithJacket
1/0 19 wire 9 14 0.37 1.12 1.23 1.35 1.46 325.8 119.2 659 4926
2/0 19 wire 11 14 0.42 1.17 1.27 1.40 1.50 410.9 146.3 775 808
3/0 19 wire 14 14 0.47 1.22 1.32 1.48 1.59 518.1 185.9 900 923
4/0 19 wire 11 12 0.53 1.28 1.38 1.54 1.71 653.3 228.0 1110 1055
250 37 wire 13 12 0.57 1.33 1.44 1.64 1.81 771.9 282.1 1330 1292
350 37 wire 12 10 0.68 1.44 1.54 1.70 1.89 1081 398.0 1633 1519
500 37 wire 17 10 0.81 1.57 1.72 1.88 2.04 1544 543.5 2002 1886
750 61 wire 25 10 0.99 1.76 1.93 2.11 2.28 2316 801.5 2650 2289
1000 61 wire 33 10 1.14 1.92 2.06 2.27 2.43 3088 1058 3847 2960

FACTORY VIEW

QA&QCCUSTOMER VISIT
CABLE LOADINGCERTIFICATE

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.