Mv-90, Power Cable, 25 Kv, 1/C, Cu/XLPE/Cws/PVC (ICEA S-93-639/NEMA WC74/UL 1072)

Mv-90, Power Cable, 25 Kv, 1/C, Cu/XLPE/Cws/PVC (ICEA S-93-639/NEMA WC74/UL 1072)

Mv-90, Power Cable, 25 Kv, 1/C, Cu/XLPE/Cws/PVC (ICEA S-93-639/NEMA WC74/UL 1072)

MV-90

Construction, Underground, Industrial, Power Station

Low and Medium Voltage Cable

DC Cable

XLPE

PVC

Round Wire

Bare Copper Wire

ISO, CCC

Mv-90

Boan

25 Kv

1

1 AWG-1000 Mcm

B

100% or 133%

DingAn

Heated Steel-Wooden Drum/Steel Drum

SGS

Jiangsu Yixing, China

8544601200

Product Description

MV-90, Power Cable, 25 KV, 1/C, Cu/XLPE/CWS/PVC (ICEA S-93-639/NEMA WC74/UL 1072)

Features
UL Listed as MV-90. Rated as Sunlight Resistance. Oil Resistance I jacket. True Triple extrusion system and
closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.

Application

Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry
locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.

Standards

UL 1072: Medium Voltage Power Cables.
ICEA S-93-639/NEMA WC74: 5 kV – 46 kV Shielded Power Cables.
ICEA S-97-682: Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.
AEIC CS8: Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.

Specifications

Maximum operating voltage: 5 kV to 35 kV 100% and 133% IL
Maximum conductor operation temperatures: Wet and dry locations: Normal: 90 °C, Emergency: 130 °C, Short Circuit: 250 °C

Engineering Information
1. Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400. On request, strand filled or compressed strand. Sizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset crosslinked polyethylene (XLPE). On request, TR-XLPE.
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Solid soft annealed uncoated copper wires per ASTM B3, helically applied and uniformly spaced.
6. Binder Tape: A suitable tape, as required.
7. Jacket: Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.

100% Insulation Levels (260 mil) 133% Insulation Levels (320 mil)
Size Number of Strands Conductor Nominal Diameter Over Insulation Jacket Thickness Approximate Outside Diameter Approximate Net Weight Diameter Over Insulation Jacket Thickness Approximate Outside Diameter Approximate Net Weight
Copper Aluminum Copper Aluminum
AWG of kcmil in in mil in lb/kft in mil in lb/kft
1 19 0.3 0.85 80 1.14 715 535
1/0 19 0.34 0.89 80 1.18 804 577 1.01 80 1.32 929 702
2/0 19 0.38 0.93 80 1.22 913 627 1.05 80 1.36 1042 756
3/0 19 0.42 0.98 80 1.27 1048 688 1.10 80 1.41 1181 821
4/0 19 0.48 1.03 80 1.34 1238 783 1.15 80 1.46 1353 898
250 37 0.52 1.09 80 1.4 1399 861 1.21 80 1.52 1517 980
300 37 0.57 1.14 80 1.45 1583 939 1.26 80 1.57 1706 1061
350 37 0.62 1.18 80 1.49 1767 1014 1.30 80 1.61 1893 1139
400 37 0.66 1.22 80 1.54 1947 1087 1.34 80 1.66 2076 1216
500 37 0.74 1.3 80 1.61 2304 1229 1.42 110 1.79 2544 1469
600 61 0.81 1.39 110 1.76 2778 1487 1.51 110 1.91 2972 1682
750 61 0.91 1.48 110 1.86 3305 1692 1.60 110 2.01 3509 1896
1000 61 1.06 1.64 110 2.04 4228 2078 1.76 110 2.16 4398 2248