Mv-105, Power Cable, 15 Kv, 3/C, Cu/Epr/Cts/CPE (ICEA S-93-639/NEMA WC71/UL 1072)

Mv-105, Power Cable, 15 Kv, 3/C, Cu/Epr/Cts/CPE (ICEA S-93-639/NEMA WC71/UL 1072)

Mv-105, Power Cable, 15 Kv, 3/C, Cu/Epr/Cts/CPE (ICEA S-93-639/NEMA WC71/UL 1072)

MV-105

Construction, Underground, Industrial, Power Station

Low and Medium Voltage Cable

DC Cable

Rubber

CPE

Round Wire

Bare Copper Wire

ISO, CCC

Mv-105

Boan

15 Kv

3

2 AWG-500 Mcm

B

Tinned Copper Tape

DingAn

Heated Steel-Wooden Drum/Steel Drum

SGS

Jiangsu Yixing, China

8544601200

Product Description

MV-105, Power Cable, 15 KV, 3/C, Cu/EPR/Cts/CPE (ICEA S-93-639/NEMA WC71/UL 1072)

Features
UL Listed as MV-105. True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.

Application
Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry
locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.

Standards
UL 1072: Medium Voltage Power Cables.
ICEA S-93-639/NEMA WC74: 5 kV – 46 kV Shielded Power Cables.
ICEA S-97-682: Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.
AEIC CS8: Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV- 46 kV.

Specifications
Maximum operating voltage: 5 kV to 25 kV 100% and 133% IL
Maximum conductor operation temperatures: Wet and dry locations, Normal: 105°C, Emergency: 140°C, Short Circuit: 250°C

Engineering Information
1. Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset ethylene propylene rubber (EPR). On request, Amorphous EPR.
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Soft annealed tinned copper tape, 5 mil thick, 25% minimum overlap.
6. Grounding (Optional): One or three tinned copper or covered conductors cabled with phase conductors.
7. Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
8. Jacket: Black sunlight resistance and flame retardant chlorinated polyethylene (CPE) compound.

100% Insulation Levels (175 mil) 133% Insulation Levels (220 mil)
Size Number of Strands Conductor Nominal Jacket Thickness Approximate Outside Diameter Approximate Net Weight Jacket Thickness Approximate Outside Diameter Approximate Net Weight
Copper Aluminum Copper Aluminum
AWG of kcmil in mil in lb/kft mil in lb/kft
2 7 0.27 110 1.94 2180 1740 110 2.14 2495 2055
1 19 0.3 110 2.01 2462 1906 110 2.21 2786 2231
1/0 19 0.34 110 2.09 2767 2066 110 2.29 3103 2401
2/0 19 0.38 110 2.17 3137 2253 110 2.37 3484 2601
3/0 19 0.42 110 2.27 3623 2508 110 2.47 3984 2869
4/0 19 0.48 110 2.39 4183 2779 110 2.59 4560 3156
250 37 0.52 110 2.51 4739 3078 110 2.76 5231 3570
300 37 0.57 110 2.66 5448 3456 140 2.94 6064 4073
350 37 0.62 140 2.83 6257 3932 140 3.04 6700 4375
400 37 0.66 140 2.93 6909 4253 140 3.13 7365 4709
500 37 0.74 140 3.09 8106 4785 140 3.29 8585 5264

Tags: , ,