Medium Voltage XLPE Insulated Power Cable From Hebei Huatong Cables Group

Medium Voltage XLPE Insulated Power Cable From Hebei Huatong Cables Group

Medium Voltage XLPE Insulated Power Cable From Henan Jinyuan Cables Group

Medium Voltage Power Cable

Power Station

Power Transmission

Low and Medium Voltage Cable

AC Cable

PVC

Copper

Round Wire

Steel

IEC BS

Yjlv

JYTOP

JYTOP

Steel-Wooden Drum, Steel Drum

IEC BS

China

8544492100

Product Description

Medium Voltage XLPE Insulated Power Cable From Henan Jinyuan Cables Group



1 Product Standard

This product is manufactured according to GB/T12706.2, equivalent to IEC60502.2. Or BS, DIN, ICEA standard as customer request.

2 Application
The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv.

3 Operating characteristics
– Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv.
– Max.admissible operating temperature of the conductor:90ºC.
– Max. short-circurt temperature of conductor shall not exceed 2500C. (5s maximum duration)
– The ambient temperature under installation should not below 00C.
– The bending radius of a single-core cable should not less than 20 times of the cable diameter.
The bending radius of a multi-core cable should not less than 15 times of the cable diameter.

4 Table of the voltage, cores and cross-section

Item Category A ,B 3.6/6kV 6/10kV 8.7/15kV 12/20kV 18/30kV 21/35kV
Category A ,B 6/6kV 8.7/10kV 12/15kV 18/20kV 26/35kV
Single core mm2 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
Three core mm2 25-400 25-400 35-400 50-400 50-400 50-400


The cable with Category A rated voltage is used in the situation requiring not over 1 min. of grounding fault lasting time. For the cable with
Category B rated voltage, the grounding fault lasting time normally is not over 1 hour, max. lasting time is not over 8 hours, annual ground fault
lasting time altogether should not be over 125 hours, Category C includes all the system expect Category A and B.

5 Type and Name

Type Designation Applications
YJV Copper conductor,XLPE insulated,
PVC sheathed power cable
For laying indoors,in tunnel or cable trench,
unable to bear external mechanical forces.
Single core cable is not allowed to laid in magnetic duct.
YJLV Aluminum conductor,XLPE insulated,
PVC sheathed power cable
YJY Copper conductor, XLPE insulated,
PE sheathed power cable
YJLY Aluminum conductor, XLPE insulated,
PE sheathed power cable
YJV22 Copper conductor,XLPE insulated,steel
tape armoured,PVC sheathed power cable
For laying indoors,in tunnel in cable trench,or direct in
ground,able to bear external mechanical forces.Single core
cable is not allowed to laid in magnetic duct.
YJLV22 Aluminum conductor,XLPE insulated,steel
tape armoured,PVC sheathed power cable
YJV23 Copper conductor,XLPE insulated,steel
tape armoured,PE sheathed power cable
YJLV23 Aluminum conductor,XLPE insulated,steel
tape armoured,PE sheathed power cable
YJV32 Copper conductor,XLPE insulated,steel
wire armoured,PVC sheathed power cable
For laying indoors,in tunnel cable trench,well or direct in
ground,able to bear external mechanical forces and certain pulling force.
YJLV32 Aluminum conductor,XLPE insulated,steel
wire armoured,PVC sheathed power cable
YJV33 Copper conductor,XLPE insulated,steel
wire armoured,PE sheathed power cable
YJLV33 Aluminum conductor,XLPE insulated,
steel wire armoured,PE sheathed power cable

Tags: , ,