Medium Voltage XLPE Insulated Power Cable

Medium Voltage XLPE Insulated Power Cable

Medium Voltage XLPE Insulated Power Cable

YJV/YJV22/YJV32

Construction, Underground

Low and Medium Voltage Cable

DC & AC

XLPE

None

ISO, CE

SABS

Henan Jiapu

Accord with The Request

IEC60502 or Others

2000km/Month

1km

Jiapu

Wooden Drum or Wooden&Steel Drum

IEC, ASTM, DIN, BS, GB, Any standard

Henan China

8544492100

Product Description

Medium Voltage XLPE Insulated Power Cable

Application :
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Property:

1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.

Workshop:

Shipment:

Specification:

1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor Nominal Diameter of Conductor Nominal Thickness of Insulation Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25 6 2.5 0.1 1.2 0.2 1.9 37.9 1.87 2.32
3 X 35 6.9 2.5 0.1 1.3 0.5 2 41.5 2.1 2.73
3 X50 8.2 2.5 0.1 1.3 0.5 2 44.3 2.37 3.22
3 X 70 9.7 2.5 0.1 1.4 0.5 2.1 47.9 2.77 4
3 X 95 11.3 2.5 0.1 1.4 0.5 2.2 51.6 3.21 4.91
3 X 120 12.8 2.5 0.1 1.5 0.5 2.4 55.4 3.69 5.84
3 X 150 14.2 2.5 0.1 1.5 0.5 2.5 58.6 4.15 6.85
3 X 185 15.9 2.5 0.1 1.5 0.5 2.6 62.5 4.73 8.11
3 X 240 18.3 2.6 0.1 1.6 0.5 2.7 68.5 5.62 10.05
3 X 300 20.4 2.8 0.1 1.7 0.5 2.9 74.5 6.55 12.11
3 X 400 23.2 3 0.1 1.9 0.8 3.2 83.6 8.78 15.86
3 X 500 26.4 3.2 0.1 2.1 0.8 3.4 93 10.52 18.85
2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor Nominal Diameter of Conductor Nominal Thickness of Insulation Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25 6 3.4 0.1 1.3 0.5 2 43.4 2.16 2.61
3 X 35 6.9 3.4 0.1 1.3 0.5 2 45.4 2.36 2.99
3 X50 8.2 3.4 0.1 1.4 0.5 2.2 48.8 2.69 3.54
3 X 70 9.7 3.4 0.1 1.5 0.5 2.3 52.4 3.1 4.33
3 X 95 11.3 3.4 0.1 1.5 0.5 2.4 56.1 3.56 5.26
3 X 120 12.8 3.4 0.1 1.5 0.5 2.5 59.5 4.04 6.19
3 X 150 14.2 3.4 0.1 1.5 0.5 2.6 62.7 4.49 7.19
3 X 185 15.9 3.4 0.1 1.6 0.5 2.6 66.6 5.12 8.49
3 X 240 18.3 3.4 0.1 1.7 0.5 2.8 72.4 5.99 10.42
3 X 300 20.4 3.4 0.1 1.8 0.5 3 77.5 6.86 12.42
3 X 400 23.2 3.4 0.1 1.9 0.8 3.2 85.4 8.97 16.05
3 X 500 26.4 3.4 0.1 2 0.8 3.4 93.7 10.65 19.5
3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor Nominal Diameter of Conductor Nominal Thickness of Insulation Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25 6 4.5 0.1 1.4 0.5 2.1 48.6 2.53 2.98
3 X 35 6.9 4.5 0.1 1.4 0.5 2.2 50.7 2.76 3.39
3 X50 8.2 4.5 0.1 1.5 0.5 2.3 53.9 3.1 3.95
3 X 70 9.7 4.5 0.1 1.5 0.5 2.4 57.4 3.51 4.74
3 X 95 11.3 4.5 0.1 1.5 0.5 2.6 61.2 4.05 5.75
3 X 120 12.8 4.5 0.1 1.6 0.5 2.6 64.7 4.56 6.72
3 X 150 14.2 4.5 0.1 1.6 0.5 2.7 67.9 5.04 7.74
3 X 185 15.9 4.5 0.1 1.7 0.5 2.8 71.9 5.66 9.04
3 X 240 18.3 4.5 0.1 1.8 0.5 3 77.7 6.56 11
3 X 300 20.4 4.5 0.1 1.9 0.8 3.2 84.1 8.39 13.96
3 X 400 23.2 4.5 0.1 2 0.8 3.3 90.5 9.71 16.79
3 X 500 26.4 4.5 0.1 2.1 0.8 3.5 98.8 11.45 20.57
4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor Nominal Diameter of Conductor Nominal Thickness of Insulation Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25
3 X 35 6.9 5.5 0.1 1.5 0.5 2.4 55.6 3.14 3.77
3 X50 8.2 5.5 0.1 1.5 0.5 2.5 58.6 3.49 4.34
3 X 70 9.7 5.5 0.1 1.5 0.5 2.6 62.1 3.93 5.16
3 X 95 11.3 5.5 0.1 1.6 0.5 2.6 65.7 4.46 6.16
3 X 120 12.8 5.5 0.1 1.7 0.5 2.7 69.4 5 7.15
3 X 150 14.2 5.5 0.1 1.7 0.5 2.8 72.6 5.49 8.19
3 X 185 15.9 5.5 0.1 1.8 0.5 3 76.9 6.16 9.53
3 X 240 18.3 5.5 0.1 1.9 0.8 3.2 83.9 7.87 12.31
3 X 300 20.4 5.5 0.1 2 0.8 3.2 88.6 8.96 14.52
3 X 400 23.2 5.5 0.1 2.1 0.8 3.5 95.4 10.35 17.43
3 X 500 26.4 5.5 0.1 2.2 0.8 3.7 103.7 12.45 20.23
5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor Nominal Diameter of Conductor Nominal Thickness of Insulation Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25
3 X 35
3 X50 8.2 8 0.1 1.7 0.5 2.8 70.4 4.56 5.41
3 X 70 9.7 8 0.1 1.7 0.5 2.9 73.9 5.04 6.26
3 X 95 11.3 8 0.1 1.8 0.5 3 77.7 5.62 7.32
3 X 120 12.8 8 0.1 1.9 0.8 3.2 82.8 6.99 9.15
3 X 150 14.2 8 0.1 1.9 0.8 3.2 85.8 7.56 10.26
3 X 185 15.9 8 0.1 2 0.8 3.3 89.9 8.3 11.67
3 X 240 18.3 8 0.1 2.1 0.8 3.5 95.7 9.36 13.79
3 X 300 20.4 8 0.1 2.2 0.8 3.6 100.6 10.51 16.07
3 X 400 23.2 8 0.1 2.3 0.8 3.8 107.2 11.99 19.07
3 X 500 26.4 8 0.1 2.4 0.8 4 120.1 14.15 23.85

Certification:

FAQ:

1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China

2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;

2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;

3)PVC Insulated (Flexible ) Wire ;

4) PVC Insulated and Sheathed (Armoured) Power Cable;

5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;

6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;

3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS

4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.

5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.

6. What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet
with the requirement If you have special request.

7. What is the production capacity per week or per month ?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.

8. Do you supply the customers with installation service in foreign country ?
We don’t have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.