Medium Voltage Aluminum Conductor XLPE Insulated PE Sheathed Single Core Power Cable

Medium Voltage Aluminum Conductor XLPE Insulated PE Sheathed Single Core Power Cable

Medium Voltage Aluminum Conductor XLPE Insulated PE Sheathed Single Core Power Cable

YJLV 1

Underground

Medium Voltage

DC & AC

XLPE

PE

Round Wire

Copper Wire

ISO, CCC, CE

Cu/XLPE/PE

Hongda

1 Core

Hongda

Wooden Drum or Flexible Package

Zhengzhou China

8544492100

Product Description

Medium Voltage Aluminum Conductor XLPE Insulated PE Sheathed Single Core Power Cable

Application
XLPE insulated cable functions well for electricity transmission and distribution lines for its excellent electrical and physical properties, including the advantage of simplicity in construction, lightness in weight; convenience in application besides its excellent electrical, thermal, mechanical and anti-chemical corrosion properties. Laying indoors, in tunnel, fixed on the bracket, pipe and buried in the soil, the cable cannot bear external mechanical forces.

Standard
IEC60502,IEC 60228,IEC60332, BS 5467, BS 6622, IS 1554, IS 7098 and ICEA S-66-524 etc.
Hongda Cable can also design and produce for special application requirement.

Product Range
Rated voltage: 3.6/6(7.2)kV,6/6(7.2)kV, 6/10(12)kV, 8.7/10(12)kV
No. of Cores: single core
The ambient temperature for installation: ≥0ºC
Max. conductor temperature in normal operation:≤90ºC
Max. operating temperature of conductor when cable short-circuited (5s maximum duration): 250ºC

Construction
Conductor: Stranded aluminium conductor to IEC60228 class 2
Conductor Screen: Extruded semi-conductive compound
Insulation: XLPE (cross-linked polyethylene) rated at 90°C
Insulation Screen: Extruded semi-conductive compound
Metallic Screen: copper tape or a concentric layer of copper wires
Inner Sheath: Extruded PE
Outer Sheath: PE

Main Technical Parameters

  1. D.C. Resistance and Short-circuit Current of Aluminum Conductor (reference value)
Nominal Section Area of Aluminum Conductor
(mm2)
Max. Permissible D.C. Resistance of Conductor at 20ºC (Ω/km) Maximum Permissible Short-circuit Current for Conductor (1s) (kA)
1.5 0.13
2.5 12.1 0.22
4 7.41 0.34
6 4.61 0.51
10 3.08 0.99
16 1.91 1.56
25 1.20 2.42
35 0.868 3.37
50 0.641 4.79
70 0.443 6.68
95 0.320 9.03
120 0.253 11.4
150 0.206 14.2
185 0.164 17.5
240 0.125 22.6
300 0.100 28.2
400 0.0778 37.65
500 0.0605 47.0
630 0.0469 58.0
  1. Capacitance and Inductance of Cable (reference value)
  1. Capacitance
Nominal Section Area of Aluminum Conductor (mm2) Rated Voltage (kV)
3.6/6 6/6
6/10
8.7/10
8.7/15
12/20 18/30 21/35 26/35
Capacitance for Each Phase (μF/km)
25 0.2423 0.1922 0.1576
35 0.2684 0.2116 0.1725 0.1502
50 0.3022 0.2367 0.1917 0.1661 0.1363 0.1239 0.1150
70 0.3462 0.2693 0.2167 0.1868 0.1508 0.1365 0.1263
95 0.3875 0.2999 0.2400 0.2060 0.1643 0.1483 0.1368
120 0.4236 0.3266 0.2603 0.2228 0.1760 0.1584 0.1460
150 0.4647 0.3570 0.2834 0.2418 0.1893 0.1700 0.1563
185 0.5059 0.3873 0.3123 0.2656 0.2060 0.1815 0.1665
240 0.5430 0.4290 0.3439 0.2916 0.2207 0.1972 0.1805
300 0.5589 0.4706 0.3755 0.3175 0.2387 0.2128 0.1945
400 0.5940 0.5311 0.4213 0.3551 0.2648 0.2354 0.2146
500 0.6167 0.5839 0.4613 0.3880 0.2876 0.2551 0.2321
630 0.6848 0.6481 0.5099 0.4278 0.3151 0.2789 0.2333

(2) Inductance for single core cable (S=2D)

Nominal Section Area of Aluminum Conductor (mm2) Rated Voltage (kV)
3.6/6 6/6
6/10
8.7/10
8.7/15
12/20 18/30 21/35 26/35
Inductance (MH/km)
25 0.5954 0.6143 0.6474
35 0.5753 0.5932 0.6248 0.6390
50 0.5543 0.5711 0.6011 0.6145 0.6501 0.6675 0.6751
70 0.5357 0.5486 0.5765 0.5919 0.6252 0.6394 0.6467
95 0.5172 0.5318 0.5608 0.5726 0.6043 0.6180 0.6279
120 0.5059 0.5197 0.5473 0.5586 0.5891 0.6051 0.6118
150 0.4949 0.5079 0.5341 0.5449 0.5740 0.5895 0.5959
185 0.4885 0.5006 0.5252 0.5354 0.5640 0.5760 0.5839
240 0.4790 0.4890 0.5143 0.5216 0.5487 0.5615 0.5677
300 0.4749 0.4818 0.5032 0.5102 0.5376 0.5484 0.5540
400 0.4660 0.4702 0.4927 0.4991 0.5219 0.5343 0.5395
500 0.4600 0.4619 0.4848 0.4907 0.5128 0.5224 0.5272
630 0.4547 0.4563 0.4748 0.4827 0.5012 0.5101 0.5161

Note: S-The distance between the two adjacent cable center, D-The overall diameter of the cables.

3. The Laying of the Cable Ampacity Correction in Different Environments
(1) Rating factors of current rating for ambient temperature:

Ambient Temperature 20ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
Rating Factors 1.18 1.14 1.10 1.05 1.0 0.95 0.89

(2) Directly buried into ground
a) When the single core cables are installed separately, the distance between the cables is 2 times of the cable’s diameter.
b) Ambient temperature: 25ºC
c) Soil thermal resistivity: 1.0ºC.m/W
d) Depth: 0.7m
e) Rating factors under different ambient temperature

Ambient Temperature 15ºC 20ºC 25ºC 30ºC 35ºC 40ºC 45ºC
Rating Factors 1.07 1.04 1.00 0.96 0.92 0.87 0.83

f) The correct coefficients of ground thermal resistivity

Thermal Resistive ºC.m/W 0.6 0.8 1.0 1.2 1.4 1.6 2.0
Rating Factors 1.17 1.08 1.00 0.94 0.89 0.84 0.77

Current Rating Conditions:
Ground Temperature: 25°C
Ambient Temperature (air): 30°C
Depth of Soil: 0.8 m
Thermal Resistance of Soil: 1.0ºC.m/W
Certificate

Contact Us
If you have more questions, please contact with Ellen Zhang.
Ellen Zhang
Phone: 86 150 0380 6907




Factory

Henan Hongda Cable Co., Ltd. located in No. 3, Changping Road, ZhanDian District, Jiaozuo, Wuzhi. Our factroy established in March of 2004. Our owns registered capital of RMB Fifty-one million six hundred and eighty thousand. Hongda Cable
covers an area of 100,000 square meters, including 50,000 square meters of building area. We have more than 120 staff members and professional workers. our fixed assets of 90,000,000. We can provide more than 100 varieties, tens of thousands of specifications of wire and cable, with 10000 km annual production capacity
Henan Hongda Cable Co. Ltd. is the original Zhengzhou Hongda Cable Co. Ltd. established enterprise expansion. The company is committed to system R&D, design, manufacturing, marketing and service of cable products,We mainly aim at managing cross-linking XLPE insulated power cables, PVC insulated power cables, plastic insulated control cables, insulated overhead cables, and stranded aluminum and ACSR. At present, the cables’ biggest cross area is 800 square meters with a maximum electric power of 35KV. The company has more than 300 (sets) domestic and oversea-leading production and testing equipment.

Packing and Transportation

We provide you with the best product packaging design services, thereby allowing you to save more shipping charges

FAQ
Q: Are you the factory or the trading company?

A: We are the factory.
Q: How long is your guarantee Period?
A: We uaually offer 1 year guarantee for our general products.
Q: How can I get the samples?
A: We can make the sample order. And usually we will charge for it.
But the samples fee will be return to you when you make the bulk order.
Q: Where is your factory? How can we visit your factory?
A: Our factory located in Zhengzhou city, Henan Province. You could reach here by train and by air.
We can pick you up in the airport and the railway station.
Q; What is your MOQ?
A: It`s base on the cable type or wire type. Please contact me. We will let you know.

Tags: , ,