Medium URD Cable, 28 KV, CU/TR-XLPE/Neutral/PVC (AEIC CS 8/ICEA S-94-649)
Applications:
Predominantly used for primary underground distribution; Suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 15, 000 volts or less and at conductor temperatures not to exceed 90° C for normal operation.
Specifications:
Primary UD Cable meets or exceeds the following ASTM specifications:
B-3 Soft Annealed Copper Wire.
B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft.
B-230 Aluminum, 1350-H19 Wire for Electrical Purposes.
B-231 Aluminum 1350 Conductors, Concentric-Lay-Stranded.
B-609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes.
Primary UD Cable is manufactured to the latest edition of the following specifications, and in case of specification conflicts, in the order listed:
ANSI/ICEA S-94-649
AEIC CS-8
RUS U-1
Construction:
The phase conductor is concentrically stranded, compressed soft copper or 1350-H16/26 aluminum alloy. The cable is composed of the conductor with moisture block in the strands, covered by a semi-conducting cross-linked polyethylene strand shield, a tree-retardant cross-linked polyethylene primary insulation, and a semi-conducting cross-linked polyethylene insulation shield. Conductors are available with either 100% or 133% insulation levels. A concentric neutral of bare copper wires and an insulating polyethylene jacket is applied over the insulation shield. The cable is identified by surface print on the jacket and with the lightning bolt symbol for supply cables indented in the jacket. A semi-conducting polyethylene jacket is available upon request.
Maximum Conductor Normal Operation: – 90O C;
Emergency Overload: – 130O C
Temperatures: Short Circuit – 250 C
Application: Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
Applications:
Predominantly used for primary underground distribution; Suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 15, 000 volts or less and at conductor temperatures not to exceed 90° C for normal operation.
Specifications:
Primary UD Cable meets or exceeds the following ASTM specifications:
B-3 Soft Annealed Copper Wire.
B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft.
B-230 Aluminum, 1350-H19 Wire for Electrical Purposes.
B-231 Aluminum 1350 Conductors, Concentric-Lay-Stranded.
B-609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes.
Primary UD Cable is manufactured to the latest edition of the following specifications, and in case of specification conflicts, in the order listed:
ANSI/ICEA S-94-649
AEIC CS-8
RUS U-1
Construction:
The phase conductor is concentrically stranded, compressed soft copper or 1350-H16/26 aluminum alloy. The cable is composed of the conductor with moisture block in the strands, covered by a semi-conducting cross-linked polyethylene strand shield, a tree-retardant cross-linked polyethylene primary insulation, and a semi-conducting cross-linked polyethylene insulation shield. Conductors are available with either 100% or 133% insulation levels. A concentric neutral of bare copper wires and an insulating polyethylene jacket is applied over the insulation shield. The cable is identified by surface print on the jacket and with the lightning bolt symbol for supply cables indented in the jacket. A semi-conducting polyethylene jacket is available upon request.
Maximum Conductor Normal Operation: – 90O C;
Emergency Overload: – 130O C
Temperatures: Short Circuit – 250 C
Application: Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
Conductor | Insulation Thickness | Concentric Neutral | Conductor Diameter | Insulation Diameter | Insulation Shield Diameter | Jacket Diameter | Cable Weight |
mils | AWG | mm | mm | mm | mm | kg/km | |
28kV 100% Copper Single Phase – Full Neutral | |||||||
1 SOLID CU | 280 | 13-#12 | 7.34 | 23.04 | 24.92 | 31.87 | 1439 |
1 AWG CU | 280 | 13-#12 | 7.59 | 23.19 | 25.07 | 32.02 | 1452 |
1/0 SOLID CU | 280 | 16-#12 | 8.26 | 23.95 | 25.83 | 32.78 | 1657 |
1/0 AWG CU | 280 | 16-#12 | 8.59 | 24.18 | 26.06 | 33.01 | 1672 |
2/0 AWG CU | 280 | 20-#12 | 9.60 | 25.20 | 27.08 | 34.03 | 1947 |
3/0 AWG CU | 280 | 26-#12 | 10.82 | 26.42 | 28.75 | 35.70 | 2349 |
4/0 AWG CU | 280 | 32-#12 | 12.14 | 27.74 | 30.07 | 37.02 | 2767 |
28kV 100% Copper Three Phase – One-Third Neutral | |||||||
1 SOLID CU | 280 | 11-#16 | 7.34 | 23.04 | 24.92 | 30.34 | 1125 |
1 AWG CU | 280 | 11-#16 | 7.59 | 23.19 | 25.07 | 30.50 | 1138 |
1/0 SOLID CU | 280 | 14-#16 | 8.26 | 23.95 | 25.83 | 31.26 | 1290 |
1/0 AWG CU | 280 | 14-#16 | 8.59 | 24.18 | 26.06 | 31.49 | 1304 |
2/0 AWG CU | 280 | 17-#16 | 9.60 | 25.20 | 27.08 | 32.50 | 1497 |
3/0 AWG CU | 280 | 21-#16 | 10.82 | 26.42 | 28.75 | 34.18 | 1770 |
4/0 AWG CU | 280 | 27-#16 | 12.14 | 27.74 | 30.07 | 35.50 | 2082 |
250 MCM CU | 280 | 21-#14 | 13.28 | 29.13 | 31.47 | 37.57 | 2440 |
350 MCM CU | 280 | 28-#14 | 15.72 | 31.57 | 33.91 | 40.01 | 3113 |
500 MCM CU | 280 | 26-#12 | 18.77 | 34.62 | 36.96 | 45.33 | 4294 |
750 MCM CU | 280 | 25-#10 | 24.59 | 40.69 | 43.89 | 53.34 | 6284 |
1000 MCM CU | 280 | 32-#10 | 28.37 | 44.48 | 47.68 | 57.12 | 7930 |
28kV 133% Copper Single Phase – Full Neutral | |||||||
1/0 SOLID CU | 345 | 16-#12 | 8.26 | 27.41 | 29.74 | 36.69 | 1863 |
1/0 AWG CU | 345 | 16-#12 | 8.59 | 27.64 | 29.97 | 36.92 | 1879 |
2/0 AWG CU | 345 | 20-#12 | 9.60 | 28.65 | 30.99 | 37.94 | 2160 |
3/0 AWG CU | 345 | 26-#12 | 10.82 | 29.87 | 32.21 | 39.16 | 2538 |
4/0 AWG CU | 345 | 32-#12 | 12.14 | 31.19 | 33.53 | 40.48 | 2962 |
28kV 133% Copper Three Phase – One-Third Neutral | |||||||
1/0 SOLID CU | 345 | 14-#16 | 8.26 | 27.41 | 29.74 | 35.17 | 1486 |
1/0 AWG CU | 345 | 14-#16 | 8.59 | 27.64 | 29.97 | 35.40 | 1502 |
2/0 AWG CU | 345 | 17-#16 | 9.60 | 28.65 | 30.99 | 36.41 | 1701 |
3/0 AWG CU | 345 | 21-#16 | 10.82 | 29.87 | 32.21 | 37.63 | 1951 |
4/0 AWG CU | 345 | 27-#16 | 12.14 | 31.19 | 33.53 | 38.95 | 2269 |
250 MCM CU | 345 | 21-#14 | 13.28 | 32.59 | 34.93 | 41.03 | 2638 |
350 MCM CU | 345 | 28-#14 | 15.72 | 35.03 | 37.36 | 44.89 | 3405 |
500 MCM CU | 345 | 26-#12 | 18.77 | 38.07 | 40.41 | 48.78 | 4530 |
750 MCM CU | 345 | 25-#10 | 24.59 | 44.15 | 47.35 | 56.79 | 6561 |
1000 MCM CU | 345 | 32-#10 | 28.37 | 47.93 | 51.13 | 60.58 | 8226 |