Made in China ABC Cable / Aerial Bundle Cable

Made in China ABC Cable / Aerial Bundle Cable

Made in China ABC Cable / Aerial Bundle Cable

JS-106

Low Voltage

Overhead

Aluminum

XLPE

ISO 9001 and 14001, Ce, IQC

Ec228, 209, 60502

PVC

OEM and ODM

ASTM Standard

International Wooden Drums

10 Years

AC 0.6/1kv

Stranded

ABC Cable

High Mobility and Easy Install

Jin Shui

International Wooden Drums or as Customer Requires

Henan, China (Mainland)

Product Description

ABC cable, 33kv abc aerial bundle cable

Specifications

New type of Aerial Bundle Cable for Power tranmission, used for rebuilding of urban and forest regions.,which can improve safety

1. ABC AERIAL BUNDEL CABLE

2. STANDARD: IEC228, IEC209, IEC60502

3. Application:the product is new type of aeriel cable for power transmitting.

It is extensively used in overhead power transmission line,It improves the safety and reliance of electrified wire netting

4. Specification: Aluminiumstranded conductor(compacted), AAC messenger core (or ACSR messenger core), XLPE(or HDPE) insulated, Twisted(or parallel) power cable

ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

The permissible long-time operating temperature for aerial conductor is 70

The circumstance that long distance rare climate and ice coverage rare occurring in heavy ice area , the most biggest stress of cable at the lowest arc downing point should not exceed 60% of the distructive power at a short time .

When connecting conductors , the conductor near to the connecting tube can`t be prominient . Otherwise , the force on the operating conductors will be unbalanced after connectors are pressed , the connecting tube should be plated ny moistureproof paint in order to protect from corroding .

Under installation , the arc downing stress of all the conductors at home distance ot the ground and across building can be 10-15% higher than regular tension.

Product Description

XLPE insulation + One sheath lighting aluminium conductor with XLPE insulation (optional) + One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanised steel wire also. The purpose of messenger wire is A) It acts as load bearing wire. B) It acts as earth or neutral conductor.
To be used at voltages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75 for polyethylene insulated conductors or 90 for crossliked polyethylene(XLPE) insulated conductors.
It meets or exceeds the following specifications: 1. Aluminum Wire, 1350-H19 for Electrical Purposes. 2. Aluminum Conductors, Concentric-Lay-Stranded. 3. Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR) 4. Concentric-Lay-Stranded 6201-T81 Conductors 5. Compressed Round Stranded Aluminum Conductors Using Single Input Wire. It meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

ABC Aerial cable with ACSR messenger Core

Nominal csetion area(sqmm)

Conductor structure

Insulation material

Insulation Thickness(mm)

Approx. Overall Diameter(mm)

Approx. weight

(kg/km)

Packing meters per drum

Phase

(Compacted AL)

Neutral

(bare ACSR)

(No./mm)

Aluminum

(No./mm)

Steel

(No./mm)

1×16+16

7/1.72

6/1.72

1/1.72

XLPE

1.2

12.5

121.9

250-4000m

1×25+25

7/2.15

6/2.15

1/2.15

1.2

14.9

182.2

250-4000

1×35+35

7/2.54

6/2.54

1/2.54

1.4

17.5

254.7

250-3500m

1×70+70

19/2.15

12/2.15

7/2.15

1.4

23.6

382.2

250-3000m

1×95+95

19/2.54

12/2.54

7/2.54

1.6

27.6

528.2

250-3000m

2×16+16

7/1.72

6/1.72

1/1.72

1.2

14.2

187.6

250-4000m

2×25+25

7/2.15

6/2.15

1/2.15

1.2

16.7

273.8

250-3500m

2×35+35

7/2.54

6/2.54

1/2.54

1.4

19.7

386.9

250-3500m

2×70+70

19/2.15

12/2.15

7/2.15

1.4

26.1

617.2

250-3000m

2×95+95

19/2.54

12/2.54

7/2.54

1.6

30.5

850.9

250-3500m

3×70+70

19/2.15

12/2.15

7/2.15

1.4

29.7

1024.3

250-3000m

3×95+95

19/2.54

12/2.54

7/2.54

1.6

34.6

1413.7

250-3000m

Applications

Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Construction

Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.

Remarks

Any crush or bump should be avoided during handling and transportation of the product.

The cable drum is not allowed to be placed with one flange up and the other down during transportation and storage of the products.

A moisture-proof measure should be taken during storage of the product

Corrugated aluminium pipe busbar, made of aluminium wires or aluminium alloy wires stranded around aluminium pipe.

Package and delivery

Wooden drums or as customers’ demand

general 15~30days