LV Conductor, 600V Urd Aluminum Cable, Overhead Line Cable

LV Conductor, 600V Urd Aluminum Cable, Overhead Line Cable

LV Conductor, 600V Urd Aluminum Cable, Overhead Line Cable

URD CABLE

Jinyuan

ISO9001, CE, CCC, RoHS

Oveahead

Round Wire

XLPE

No

Aluminum

Overhead, Underground

Stranded

Insulated

LV. Mv. Hv

as Per Your Customers ' Request

PVC/PE/XLPE

Jinyuan

All Wooden, Steel Wooden or Steel Package

China

8544492100

Product Description

Triplex Conductor 600V Secondary
Type URD Cable-Aluminum Conductor
 
 
Construction
 
Concentric stranded or compressed 1350-H19 aluminum conductors, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral triple yellow striped. Two phase and one neutral conductor twisted together (LH lay) or parallel if so specified. Black neutrals may be specified if desired.
 
 
Standards
 
ASTM B-230, B-231 and ICEA S-66-524 UL Standard 854 for Type USE Federal Specification JC-30B NEC
 
 

 
Code name
Phase conductor Neutral Single phase conductor (in)  
Outside diameter (in)
Weight per
1000ft
(lbs)
Ampacity
Size
AWG
 
Strand
Insulation
thickness
(mls)
Size
AWG
 
Strand
Insulation thickness(mls) Direct burial In duct
Erksine 6 7/w 60 6 7/w 60 .299 .646 143 95 70
Vassar 4 7/w 60 4 7/w 60 .345 .754 203 125 90
Stephens 2 7/w 60 4 7/w 60 .403 .842 264 165 120
Ramapo 2 7/w 60 2 7/w 60 .403 .874 294 165 120
Brenau 1/0 19/w 80 2 7/w 60 .522 1.064 408 215 160
Bergen 1/0 19/w 80 1/0 19/w 80 .522 1.133 465 215 160
Converse 2/0 19/w 80 1 19/w 80 .566 1.174 502 245 180
Hunter 2/0 19/w 80 2/0 19/w 80 .566 1.228 560 245 180
Hollins 3/0 19/w 80 1/0 19/w 80 .616 1.276 606 280 205
Rockland 3/0 19/w 80 3/0 19/w 80 .616 1.336 678 280 205
Sweetbriar 4/0 19/w 80 2/0 19/w 80 .672 1.389 739 315 240
Monmouth 4/0 19/w 80 4/0 19/w 80 .672 1.457 828 315 240
Pratt 250 37/w 95 3/0 19/w 80 .748 1.538 893 345 265
Wesleyan 350 37/w 95 4/0 19/w 80 .851 1.736 1166 415 320
Holyoke 500 37/w 95 300 37/w 95 .979 2.008 1607 495 395
Rider 500 37/w 95 350 37/w 95 .979 2.035 1663 495 395
Fairfield 750 61/w 110 500 37/w 95 1.188 2.086 2304 615 525

Ampacity: 90ºC conductor temperature, 20ºC ambient, RHO 50, 100% load factor for three conductor triplex with neutral carrying only unbalanced load. Technical data for cable with solid black neutral is identical to yellow extruded stripe data. All yellow extruded stripe cable is XLP insulation
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition. Packaging: Available 500 ft reels, 1,000 ft reels and longer lengths.
The above data are approximate and subject to normal manufacturing tolerances.

0.6/1KV Self support conductor abc cable, aerial bundle cable, 

We can supply this conductor according to different recognized standards, such as IEC Standard, ANSI/ICEA , NFC, NBR, ITP ,customer special specification also can be satisfied.

Application: ABC cable Conllie, duplex cable, service drop, overhead cable.
The basic construction is as following:

Aerial Bundle Conductor-ABC(South Africa Standard Sizes)-SANS 1418-1

Table 01 

Type of conductor or core Norminal cross-sectional area mm2 Nubmer of wires
Min.
Diameter of conductormm Resistanceat 20ºC  Ω/km Max.  Breaking force(N) Thickness of insulation (mm) Outer diameter of core(mm)
Min. Max. Min. Average Min. Min. Max.
Phase or auxiliary or non-strain-bearing netural(aluminium) +16 6 4.6 5.1 1.91 2070 1.2 0.98 7.0 7.8
25 6 5.8 6.3 1.2 3300 1.4 1.16 8.6 9.4
35 6 6.8 7.3 0.868 4500 1.6 1.34 10.0 10.9
50 6 7.9 8.4 0.641 6200 1.6 1.34 11.1 12.0
70 12 9.7 10.2 0.443 8900 1.8 1.52 13.3 14.2
95 15 11.0 12.0 0.320 12300 1.8 1.52 14.6 16.0
120 15 12.5 13.5 0.253 15600 1.8 1.52 16.3 17.5
150 15 13.9 15.0 0.206 19200 1.8 1.52 17.1 18.6
Service connection(aluminium) 16 6 4.6 5.2 1.91 2070 1.2 0.98 7.0 8.0
25 6 5.6 6.5 1.2 3300 1.4 1.16 8.6 9.6
Service connection(copper) 10 6 4.2 1.83 3600 1.2 0.98 6.2 7.0
16 6 5.3 1.15 5760 1.2 0.98 7.2 8.0
25 6 6.6 0.727 8750 1.4 1.16 8.6 9.6
    Number and nominal diameter of wires 
mm
               
Supporting 
core(aluminium alloy)
54.6 7×3.15 9.2 9.6 0.630 16600 1.6 1.34 12.3 13.0
70 7×3.50 10.0 10.4 0.500 20100 1.6 1.34 12.9 13.6
+Auxiliary conductors or cores only

When a supporting core is specified in a tender invitation,the combinations listed in Table 02 below:

Table 02

1 2
Nominal cross sectional area of supporting conductor mm2 Nominal cross-sectional areas of phase conductors mm2
54.6 25,35,50,70,95
70 70,95,120
95 95,120,150

Aerial Bundle Conductor-ABC(South Africa Custimized Size Specification)

Table 03
 

Type of conductor or core Norminal cross-sectional area mm2 Nubmer of wires Diameter of conductormm Resistanceat 20ºC  Ω/km Max.  Breaking force(N) Thickness of insulation (mm) Outer diameter of core(mm)
Min. Max. Min. Average Min. Min. Max.
Phase or auxiliary or non-strain-bearing netural(aluminium) 16 7/1.65 4.6 5.1 1.91 2070 1.2 0.98 7.0 7.8
25 7/2.15 5.8 6.3 1.2 3300 1.4 1.16 8.6 9.4
35 7/2.55 6.8 7.3 0.868 4500 1.6 1.34 10.0 10.9
50 7/2.99 7.9 8.4 0.641 6200 1.6 1.34 11.1 12.0
70 14/2.59 9.7 10.2 0.443 8900 1.8 1.52 13.3 14.2
95 19/2.59 11.0 12.0 0.320 12300 1.8 1.52 14.6 16.0
120 19/2.99 12.5 13.5 0.253 15600 1.8 1.52 16.3 17.5
150 30/2.59 13.9 15.0 0.206 19200 1.8 1.52 17.1 18.6
Service connection(aluminium) 16 7/1.65 4.6 5.2 1.91 2070 1.2 0.98 7.0 8.0
25 7/2.15 5.6 6.5 1.2 3300 1.4 1.16 8.6 9.6
Service connection(copper) 10 7/1.35 4.2 1.83 3600 1.2 0.98 6.2 7.0
16 7/1.69 5.3 1.15 5760 1.2 0.98 7.2 8.0
25 7/2.19 6.6 0.727 8750 1.4 1.16 8.6 9.6
Supporting core(aluminium alloy) 16 7/1.71 5.1 5.2 2.053 5070 1.4 1.16 7.9 8.0
25 7/2.15 6.4 6.5 1.314 8000 1.4 1.16 9.2 9.3
35 7/2.48 6.6 7.5 0.986 10300 1.6 1.34 10.7 10.8
50 7/2.89 7.7 8.4 0.720 14200 1.6 1.34 11.9 12.0
54.6 7/3.15 9.2 9.6 0.630 16600 1.6 1.34 12.3 13.0
70 7/3.50 10.0 10.4 0.500 20100 1.6 1.34 12.9 13.6
 