LSZH Control Cable 300/500 V Sheilded with Fire Retardant

LSZH Control Cable 300/500 V Sheilded with Fire Retardant

LSZH Control Cable 300/500 V Sheilded with Fire Retardant

FR-BE14

Construction, Power Station

Low and Medium Voltage Cable

DC & AC

XLPE

Lsoh Polymer Compound

Round Wire

Tinned Wire

ISO, CCC, CE, VDE

Fr-Be14

Yifang Cable

From 1.5mm2 to 300mm2

From1 to 40

XLPE

Lsoh(Low Smoke Zero Halogen)

VDE0276-604

Yifang Cable

Wooden Drum or Wooden-Steel Drum

CE SABS RoHS SGS UL CCC

Zhengzhou, China

8544492100

Product Description


Fire-Resistant Wire and Cable

Application
These cables are used in fire fighting alarm systems in hazardous area where the safety is highly required
during fire condition.

Standard:
IEC 60502
Rated Voltage:
600 / 1000 V
Conductor:
Stranded plain / tinned annealed copper
Insulation:
Flame barrier mica tape, cross-linked polyethylene
Assembly:
Cores twisted together in concentric layers and wrapped by polyester tapes
Color code:
Black continuously numbered
Screen:
Collective screen of aluminum polyester tapes with tinned drain wire and wrapped by polyester tapes
Sheath:
Halogen free, low smoke thermoplastic material, red color
Minimum bending radius:
7.5 x d (d= overall diameter)
Fire resistant property:
750oC according to IEC 331

Specification

No. of Cores x Nominal Cross Sectional Area Thickness of Insulation Thickness of Bedding Diameter of GSWB Thickness of Sheath Nominal Overall Diameter Nominal Weight
mm² mm mm mm mm mm kg/Km
2 x 1.50 0.50 0.50 0.24 0.8 8.2 109
3 x 1.00 0.50 0.50 0.24 1.0 8.3 114
3 x 1.50 0.50 0.50 0.24 1.0 9.0 138
3 x 2.50 0.60 0.50 0.24 1.0 10.3 188
3 x 4.00 0.60 0.60 0.24 1.0 11.7 256
3 x 6.00 0.70 0.60 0.24 1.1 13.6 352
4 x 1.50 0.50 0.50 0.24 1.0 9.6 161
4 x 2.50 0.60 0.50 0.24 1.0 11.1 223
4 x 4.00 0.60 0.60 0.24 1.0 12.7 310
4 x 6.00 0.70 0.60 0.24 1.1 14.8 430
5 x 1.50 0.50 0.50 0.24 1.0 10.4 189
5 x 2.50 0.60 0.60 0.24 1.0 12.0 264
5 x 6.00 0.70 0.60 0.24 1.2 16.3 523
5 x 10.00 0.80 0.80 0.30 1.2 20.0 822
5 x 16.00 0.90 0.80 0.30 1.4 23.9 1217

According to the test conditions specified by GB/T18380.3-2008, flame retardant cable points in Table 1 for A, B, C, D four grades

Flame retardantgrade <o:p> The fire temperature <o:p> The fire time Laying cable non-metallic material volume Carbonized height Self-extinguishing time Applicable to products
A <o:p> ≥815ºC <o:p> 40min <o:p> ≥7l/m<o:p> ≤2.5m<o:p> ≤1h <o:p> Flame resistant cable
B <o:p> ≥815ºC <o:p> 40min <o:p> ≥3.5<o:p>l/m ≤2.5m<o:p> ≤1h <o:p> Flame resistant cable
C <o:p> ≥815ºC <o:p> 20min <o:p> ≥1.5l/m <o:p> ≤2.5m<o:p> ≤1h <o:p> Flame resistant cable
D <o:p> ≥815ºC <o:p> 20min <o:p> ≥0.5l<o:p>l/m ≤2.5m<o:p> ≤1h <o:p> Flame resistant cable

Not only LSOH cables,our main products covers power cable 1-35kv,abc cable,control cable,rubber cable,instrument cable,AAC/ACSR bare conductors and so on.

Welcome further inquiries.