Low Voltage Power Cable with PVC Insulation Yby-O; Yby-J

Low Voltage Power Cable with PVC Insulation Yby-O; Yby-J

Low Voltage Power Cable with PVC Insulation Yby-O; Yby-J

YBY-O; YBY-J

Hongda

YJV

ISO, CCC, SGS

Bare Copper Wire

Round Wire

PVC

XLPE

DC Cable

Low and Medium Voltage Cable

Construction, Underground, Industrial, Power Station

0.6/1kv, 600/1000V, 1.1kv

Hongda or OEM

500m or 1000m Per Drum

1.5-300 mm2

China

8544492100

Product Description

Low Voltage Power Cable with PVC Insulation YBY-O; YBY-J

Uo/U  – 0.6/1 kV IEC 60502-1
Application:
YBY is used in power plants, industrial and switching installations, for street lighting, domestic power supply connections, in secondary distribution networks and other.These cables are also used as control cables for transmission of measured values control and regulation pulses.
 
These cables are preferentially used for underground application as well as for interior installation in room and cableducts and for outdoor and applications, for indoor installations, in the open air, underground and in water where greater mechanical protection an protection against accidental contact is required if damaged.

Cable construction
Construction According to IEC 60502-1
Conductor  solid or multi-strand Cu wires class 1 or 2 acc. 
Insulation IEC 60228 PVC acc. to IEC 60502
Core identification  single core-black, multiple core according to VDE 0293
Inner sheath tapes and filling compound
Armour two steel tapes or two galvanized
steel tapes
Sheath PVC type ST1 acc. IEC 60502
Color black
Technical data
Conductor resistance at 20°C According to IEC 60228 class 1 or 2
Max. conductor temperature +70°C
Max. short circuit temperature +160°C, not more than 5 sec
Rated voltage Uo/U 0.6/1 kV
Test voltage AC – 3.5 kV    50 Hz
Bending radius
-single core
-multi core
 
15 cable diameter
12 cable diameter
Flame test IEC 332 part 1

REFERENCE STANDARD

  • Design Specification: IEC60502-1
  • Conductor: IEC60228, BS EN60228
  • Flame Retardancy: IEC60332-1, BS EN60332-1

INSTALLATION REFERENCE

  • Minimum Bending Radius(mm): 8 x cable overall diameter
  • Max. Pulling Tension (N/mm2) : 70ºC

Note :
Conductor Shape
1.5 – 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 – 300 sqmm supplied in compacted circular stranded (cm) conductor shape

Standard Packing
1.5 – 50 sqmm supplied in wooden drum @ 1000 m
70 – 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
 

Dimensions – number of cores x conductor cross-section Construction Construction of individual conductor External diameter Insulation thickness Sheath thickness Conductor resistance at 20 °C Cu weight Cable weight
    nominal approx. nominal nominal max.   approx.
N x mm²   n x mm mm mm mm Ω/km kg/km kg/km
Power Cable YBY-J, YBY-O
2 x 1,5 RE 1 x 1,37 12,9 0,8 1,8 12,1 28,8 286
2 x 2,5 RE 1 x 1,74 13,7 0,8 1,8 7,41 48 423
2 x 4 RE 1 x 2,2 15,3 1 1,8 4,61 76,8 420
2 x 6 RE 1 x 2,7 16,3 1 1,8 3,08 115,2 493
2 x 10 RM 7 x 1,34 18,7 1 1,8 1,83 192 668
2 x 16 RM 7 x 1,70 20,9 1 1,8 1,15 307,2 873
2 x 25 RM 7 x 2,20 23,5 1,2 1,8 0,727 480 1201
2 x 35 RM 7 x 2,55 25,7 1,2 1,8 0,524 672 1480
2 x 50 RM 7 x 3,00 28,7 1,4 1,8 0,387 960 1881
2 x 70 RM 13 x 2,70 32,3 1,4 1,9 0,268 1344 2478
2 x 95 RM 17 x 2,70 37,9 1,6 2,1 0,193 1824 3378
2 x 120 RM 18 x 3,00 40,9 1,6 2,2 0,153 2304 4167
2 x 150 RM 22 x 3,00 44,9 1,8 2,3 0,124 2880 5091
2 x 185 RM 32 x 2,70 50,5 2 2,4 0,0991 3552 6272
2 x 240 RM 36 x 3,00 56,7 2,2 2,6 0,0754 4608 7945
2 x 300 RM 45 x 3,00 61,9 2,4 2,8 0,0601 5760 9628
                 
3 x 1,5 RE 1 x 1,37 13,4 0,8 1,8 12,1 43,2 314
3 x 2,5 RE 1 x 1,74 14,3 0,8 1,8 7,41 72 371
3 x 4 RE 1 x 2,2 16 1 1,8 4,61 115,2 476
3 x 6 RE 1 x 2,7 17,1 1 1,8 3,08 172,8 569
3 x 10 RM 7 x 1,34 19,7 1 1,8 1,83 288 783
3 x 16 RM 7 x 1,70 22,1 1 1,8 1,15 460,8 1044
3 x 25 RM 7 x 2,20 24,9 1,2 1,8 0,727 720 1463
3 x 35 SM 7 x 2,55 27,3 1,2 1,8 0,524 1008 1822
3 x 50 SM 7 x 3,00 30,7 1,4 1,9 0,387 1440 2356
3 x 70 SM 13 x 2,70 34,6 1,4 2 0,268 2016 3136
3 x 95 SM 17 x 2,70 41,2 1,6 2,1 0,193 2736 4507
3 x 120 SM 18 x 3,00 43,5 1,6 2,2 0,153 3456 5251
3 x 150 SM 22 x 3,00 48 1,8 2,4 0,124 4320 6496
3 x 185 SM 32 x 2,70 54 2 2,5 0,0991 5328 7972
3 x 240 SM 36 x 3,00 60,7 2,2 2,7 0,0754 6912 10140
3 x 300 SM 45 x 3,00 66,3 2,4 2,9 0,0601 8640 12349
 
3 x 16+10 RM/RE 7 x 1,7/7 x 1,3 23,2 1,0 / 1,0 1,8 1,15 556,8 1163
3 x 25+16 RM/RM 7 x 2,2/7 x 1,7 26,2 1,2 / 1,0 1,8 0,727 873,6 1641
3 x 35+16 SM/RM 7 x 2,5/7 x 1,7 28,2 1,2 / 1,0 1,8 0,524 1161,6 1978
3 x 50+25 SM/RM 7 x 3,/7 x 2,2 31,9 1,4 / 1,2 1,9 0,387 1680 2606
3 x 70+35 SM/RM 13 x 2,7/7 x 2,5 35,8 1,4 / 1,2 2 0,268 2352 3471
3 x 95+50 SM/RM 17 x 2,7/7 x 3 42,6 1,6 / 1,4 2,2 0,193 3216 4963
3 x 120+70 SM/RM 18 x 3/13 x 2,7 45,6 1,6 / 1,4 2,3 0,153 4128 5928
3 x 150+70 SM/RM 22 x 3/13 x 2,7 49,3 1,8 / 1,4 2,4 0,124 4992 7065
3 x 185+95 SM/RM 32 x 2,7/17 x 2,7 56,1 2,0 / 1,6 2,6 0,0991 6240 8866
3 x 240+120 SM/RM 36 x 3/18 x 3 62,4 2,2 / 1,6 2,8 0,0754 8064 11155
3 x 300+150 SM/RM 45 x 3/22 x 3 68,3 2,4 / 1,8 3 0,0601 10080 13649
 
4 x 1,5 RE 1 x 1,37 14,2 0,8 1,8 12,1 57,6 357
4 x 2,5 RE 1 x 1,74 15,1 0,8 1,8 7,41 96 424
4 x 4 RE 1 x 2,2 17,1 1 1,8 4,61 153,6 555
4 x 6 RE 1 x 2,7 18,3 1 1,8 3,08 230,4 670
4 x 10 RM 7 x 1,34 21,2 1 1,8 1,83 384 936
4 x 16 RM 7 x 1,70 23,8 1 1,8 1,15 614,4 1265
4 x 25 RM 7 x 2,20 27 1,2 1,8 0,727 960 1793
4 x 35 SM 7 x 2,55 29,6 1,2 1,8 0,524 1344 2249
4 x 50 SM 7 x 3,00 33,6 1,4 2 0,387 1920 2943
4 x 70 SM 13 x 2,70 38,7 1,4 2,1 0,268 2688 4172
4 x 95 SM 17 x 2,70 45,4 1,6 2,3 0,193 3648 5671
4 x 120 SM 18 x 3,00 48 1,6 2,4 0,153 4608 6631
4 x 150 SM 22 x 3,00 53 1,8 2,6 0,124 5760 8205
4 x 185 SM 32 x 2,70 59,6 2 2,7 0,0991 7104 10092
4 x 240 SM 36 x 3,00 67 2,2 2,9 0,0754 9216 12866
4 x 300 SM 45 x 3,00 73,2 2,4 3,1 0,0601 11520 15705
 
5 x 1,5 RE 1 x 1,37 15 0,8 1,8 12,1 72 401
5 x 2,5 RE 1 x 1,74 16,1 0,8 1,8 7,41 120 483
5 x 4 RE 1 x 2,2 18,3 1 1,8 4,61 192 640
5 x 16 RM 7 x 1,70 25,8 1 1,8 1,15 768 1472
5 x 50 SM 7 x 3,00 37 1,4 2,1 0,387 2400 3498
5 x 70 SM 13 x 2,70 42,6 1,4 2,2 0,268 3360 4956
5 x 95 SM 17 x 2,70 50 1,6 2,4 0,193 4560 6748
5 x 120 SM 18 x 3,00 53,1 1,6 2,6 0,153 5760 7941

*Further information about rating factor for certain cable arrangement can be found on supplementary technical information.

More information and other cable inquiry, pls contact Vivian Yuan as follows:

Vivian Yuan
Mobile: +86 18339931106

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.