Low Voltage Cu/XLPE/Swa/PVC Underground Copper Power Cable for Underground

Low Voltage Cu/XLPE/Swa/PVC Underground Copper Power Cable for Underground

Low Voltage Cu/XLPE/Swa/PVC Underground Copper Power Cable for Underground

YJV32, YJV22, YJV, YJLV

Underground, Industrial, Power Station

Low and Medium Voltage Cable

DC Cable

XLPE

PVC

Round Wire

Bare Copper Wire

ISO, CCC, CE

YJV

Jinshui

Jinshui

Wooden drum, Iron wooden drum, Iron drum

ASTM, IEC, BS, ICEA

China

8544492900

Product Description

low voltage CU/XLPE/SWA/PVC underground copper power cable for underground

Medium Voltage single core XLPE Insulated Steel Wire Armored PVC Sheathed Electrical power cable

All type of Medium Voltage XLPE Insulated PVC Sheathed Power Cable :
1). 3.6/6(7.2)kV,3.6/6.6(7.2)kV, Single Core, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
2). 6/10(12)kV,6.35/11(12)kV, Single Core, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
3). 8.7/10(15)kV, Single Core, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
4). 12/20(24)kV, 12.7/22(24)kV, Single Core, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
5). 18/30(36)kV,19/33(36)kV, Single Core, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
6). 3.6/6(7.2)kV,3.6/6.6(7.2)kV, Three Cores, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
7). 6/10(12)kV,6.35/11(12)kV, Three Cores, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
8). 8.7/10(15)kV, Three Cores, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
9). 12/20(24)kV, 12.7/22(24)kV, Three Cores, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
10). 18/30(36)kV,19/33(36)kV, Three Cores, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.

Application:
Medium Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 3.6kv~35kV . It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Property:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds),the highest temperature for conductor is no more than 250 degrees.
3.the environmental temperature of operating in air should be no more than 40 degrees, and 25 degrees underground.
4.Excellent electrical performance, resistance to chemical corrosion.

It shows us the most common sizes of non armoured power cable, but other sizes to any recognized standards or customer specification can also be supplied as per customer’s requirements.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.