Low Voltage Aluminium Wire Bare Alloy Porter Axka Cable 3X35+16+50mm

Low Voltage Aluminium Wire Bare Alloy Porter Axka Cable 3X35+16+50mm

Low Voltage Aluminium Wire Bare Alloy Porter Axka Cable 3X35+16+50mm

AXKA Cable

Construction, Overhead, Industrial

Low and Medium Voltage Cable

AC Cable

XLPE

N/a

Round Wire

Aluminum

ISO, CCC

SGS

Amka Cable

Hongda

600/1000V

Hongda or OEM

Export Wooden Drum

10mm to 150mm

China

8544492100

Product Description

Low voltage (0.6-1kV) Aluminium wire Bare Alloy Porter AXKA Cable 3X35+16+50
 

Low voltage (0.6-1kV) Aluminium wire Bare Alloy Porter AXKA Cable

1. AXKA Cable Specification

  Aluminium Compacted Conductor
Black HDPE /XLPE Insulation
Longitudinal Ridges
Public lighting
Bare Alloy Porter
Uo/U = 0.6/1 kV, Um = 1.2 kV
Maximum Operating Temperature : 90°C 
Maximum Short Circuit Temperature :  250°C 

2. AXKA Cable Application

Low voltage (0.6-1kV) Aluminium wire Bare Alloy Porter AXKA Cable used in power supply in power transmission and distribution line.

It is prefered to use of ABC cables instead of uninsulated conductors at low voltage networks. ABC cables are especially used at areas where the cost of underground networks is expensive and also for electrification of rural areas like villages.

 

3. AXKA Cable Standard

SFS 2200 HD 626-5D.

We can also manufacture AXKA Cable according to customer’s special requirements.

4. Construction

The basic construction is as follows: 
3 power cores consisting of standard aluminum conductors, insulated with XLPE insulation 
+ One sheath lighting aluminum conductor with XLPE insulation(optional) 
+ One messenger Al-alloy conductor (bare or covered) 
The messenger conductor can be of galvanized steel wire also. 
The purpose of messenger wire is: 
A) It acts as load bearing wire. 
B) It acts as earth or neutral conductor.

OPTIONS

AXKA Cable can be manufactured with the following options:

  • Phase Conductor
  • Other voltage
  • Other section
  • Netural conductor
  • Insulation Thickness
Cable type Phase area

Messenger

area

Lighting

area

Overall diameter

whole cable

(approx)

Net weight

of cable,

nominal value

Maximum DC

resistance

of phase 20ºC

Maximum DC

resistance

of messenger 20ºC

TWISTED OVERHEAD CABLE AXKA 1 X 16+25 16 25 11 135 1.91 1.38
TWISTED OVERHEAD CABLE AXKA 3 X 16+25 16 25 20 270 1.91 1.38
TWISTED OVERHEAD CABLE AXKA 4 X 16+25 16 25 22 330 1.91 1.38
TWISTED OVERHEAD CABLE AXKA 3 X 25+35 25 35 23 390 1.2 0.986
TWISTED OVERHEAD CABLE AXKA 3 X 25+16+35 25 35 16 25 465 1.2 0.986
TWISTED OVERHEAD CABLE AXKA 3 X 35+50 35 50 27 530 0.868 0.72
TWISTED OVERHEAD CABLE AXKA 3 X 35+16+50 35 50 16 29 610 0.868 0.72
TWISTED OVERHEAD CABLE AXKA 3 X 35+70 35 70 31 670 0.868 0.493
TWISTED OVERHEAD CABLE AXKA 3 X 50+70 50 70 31 700 0.641 0.493
TWISTED OVERHEAD CABLE AXKA 3 X 70+95 70 95 36 1000 0.443 0.363
TWISTED OVERHEAD CABLE AXKA 3 X 120+95 120 95 42 1500 0.253 0.363

 