Product Description
Wholesale Power Electric Cable With XLPE Insulated
Technical Parameters of our Power Cable
1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890
2). Detailed description or construction:
* Conductor: compacted or uncompacted copper or aluminium
* Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
* Filler: Polypropylene filament with lapped binding tape
* Binder: Binding tape
* Inner sheath: Polyvinyl chloride (PVC)
* Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)
*Sheath: Polyvinyl chloride (PVC)
3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:
U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV
4). Voltage:
0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV
In the voltage designation of cables U0/U(Um):
* U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
* U is the rated power frequency voltage between conductors for which the cable is designed;
* Um is the maximum value of the "highest system voltage" for which the equipment maybe used.
5). Application:
For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.
6). Marking: According to the customers’ requirements
7). Nominal cross-sectional areas:
1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2, 800mm2
Technical Parameters of our Power Cable
1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890
2). Detailed description or construction:
* Conductor: compacted or uncompacted copper or aluminium
* Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
* Filler: Polypropylene filament with lapped binding tape
* Binder: Binding tape
* Inner sheath: Polyvinyl chloride (PVC)
* Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)
*Sheath: Polyvinyl chloride (PVC)
3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:
U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV
4). Voltage:
0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV
In the voltage designation of cables U0/U(Um):
* U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
* U is the rated power frequency voltage between conductors for which the cable is designed;
* Um is the maximum value of the "highest system voltage" for which the equipment maybe used.
5). Application:
For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.
6). Marking: According to the customers’ requirements
7). Nominal cross-sectional areas:
1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2, 800mm2
| Type | Designation | Applications |
| VV YJV VLV YJLV |
Copper conductor, PVC ,XLPE insulated, PVC sheathed power cable Aluminium conductor, PVC ,XLPE insulated, PVC sheathed power cable |
For laying indoors, in tunnel or cable trench, unable to bear external mechanical forces. Single core cable is not permissible to lay in magnetic duct. |
| VY YJY VLY YJLY |
Copper conductor, PVC,XLPE insulated, PE sheathed power cable Aluminium conductor, PVC ,XLPE insulated, PE sheathed power cable |
|
| VV22 YJV22 VLV22 YJLV22 |
Copper conductor, PVC ,XLPE insulated, steel tape armoured, PVC sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel tape armoured, PVC sheathed power cable |
For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force. |
| VV23 YJV23 VLV23 YJLV23 |
Copper conductor, PVC ,XLPE insulated, steel tape armoured, PE sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel tape armoured, PE sheathed power cable |
|
| VV32 YJV32 VLV32 YJLV32 |
Copper conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable |
For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force. |
| VV33 YJV33 VLV33 YJLV33 |
Copper conductor, PVC ,XLPE insulated, steel wire armoured, PE sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel wire armoured, PE sheathed power cable |
|
| Note: The armoured single core cables is only used for D.C. system. As for A.C. system, non-magnetic armour material should be applied. | ||
NOTE:
If you want to know more details about this kind of products, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.
| Size |
Nominal thickness of XLPE insulation(mm) | Approx. thickness of copper tape screen (mm) | Nominal thickness of steel tape(mm) | Nominal thickness of PVC or PE(mm) | Approx. overall diameter of finished cable(mm) | Max. conductor D.C resistance @ 20ºC(Ω/km) |
| 3x25mm 2 | 3.4 | 0.10 | 0.5 | 2.3 | 45.7 | 0.727 |
| 3x35mm 2 | 3.4 | 0.10 | 0.5 | 2.4 | 48.1 | 0.524 |
| 3x50mm 2 | 3.4 | 010 | 0.5 | 2.5 | 50.9 | 0.387 |
| 3x70mm 2 | 3.4 | 0.10 | 0.5 | 2.6 | 54.8 | 0.268 |
| 3x95mm 2 | 3.4 | 0.10 | 0.5 | 2.7 | 58.8 | 0.193 |
| 3x120mm 2 | 3.4 | 0.10 | 0.5 | 2.9 | 62.4 | 0.153 |
| 3x150mm 2 | 3.4 | 0.10 | 0.5 | 3.0 | 66.2 | 0.124 |
| 3x185mm 2 | 3.4 | 0.10 | 0.5 | 3.1 | 70.1 | 0.0991 |
| 3x240mm 2 | 3.4 | 0.10 | 0.5 | 3.3 | 75.9 | 0.0754 |
| 3x300mm 2 | 3.4 | 0.10 | 0.5 | 3.4 | 80.7 | 0.0601 |
| 3x400mm 2 | 3.4 | 0.10 | 0.8 | 3.7 | 89.8 | 0.0470 |