Hot Seller Good Price AAAC Bare Power Conductor

Hot Seller Good Price AAAC Bare Power Conductor

Hot Seller Good Price AAAC Bare Power Conductor

AAAC

Construction, Industrial, Power Station

Low and Medium Voltage Cable

AC Cable

Bare

Round Wire

Aluminium Alloy

ISO, CE

SABS

Jiapu

JP

Export Wooden Drum or Wooden Steel Drum

China

7614900000

Product Description

Alloy Alumum Conductor
(1). All aluminium conductor (AAC)
(2). All aluminimum alloy conductor(AAAC)
(3). Aluminum conductor steel reinforced (ACSR)
(4). Anti-corrosion type ACSR
(5). Aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6). Rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7). Aluminimum conductor aluminimum alloy reinforced(ACAR)

2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191

AAC(All aluminum conductor) are suited for overhead power line.

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.

ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.

Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.

Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

Standard:
IEC61089 Standard

Code Number A2 Conductor A3 Conductor Max.D.C. Resistance of Conductor at 20°C
Number of Wires Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength Number of Wires Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength
mm² mm mm kg/km daN mm mm kg/km daN Ω/km
16 7 1.83 5.49 50.4 5.43 50.8 6.04 50.8 6.04 1.7896
25 7 2.29 6.87 78.7 8.49 1.1453 79.5 9.44 79.5 9.44 1.1453
40 7 2.89 8.67 125.9 13.58 0.7158 127.1 15.1 127.1 15.1 0.7158
63 7 3.63 10.8 198.3 21.39 0.4545 200.2 23.06 200.2 23.06 0.4545
100 19 2.78 13.9 316.3 33.95 0.2877 319.3 37.76 319.3 37.76 0.2877
125 19 3.10 15.5 395.4 42.44 0.2302 399.2 47.20 399.2 47.20 0.2302
160 19 3.51 17.55 506.1 54.32 0.1798 511.0 58.56 511.0 58.56 0.1798
200 19 3.93 19.65 623.7 67.91 0.1439 638.7 73.20 638.7 73.20 0.1439
250 19 4.39 21.95 790.8 84.68 0.1151 798.4 91.50 798.4 91.50 0.1151
315 37 3.53 24.71 998.9 106.95 0.0916 1008.4 115.29 1008.4 115.29 0.0916
400 37 3.98 27.86 1268.4 135.81 0.0721 1280.5 146.4o 1280.5 146.4o 0.0721
450 37 4.22 29.54 1426.9 152.79 0.0641 1440.5 164.70 1440.5 164.70 0.0641
500 37 4.45 31.15 1585.5 169.76 0.0577 1600.6 183.oo 1600.6 183.oo 0.0577
560 61 3.67 33.03 1778.4 190.14 0.0516 1795.3 204.95 1795.3 204.95 0.0516
630 61 3.89 35.01 2000.7 213.90 0.0458 2019.8 230.58 2019.8 230.58 0.0458
710 61 4.13 37.17 2254.8 241.07 0.0407 2276.2 259.86 2276.2 259.86 0.0407
800 61 4.38 39.42 2540.6 271.62 0.0361 2564.8 282.80 2564.8 282.80 0.0361
900 91 3.81 41.91 2861.1 305.58 0.0632 2888.3 329.40 2888.3 329.40 0.0321
1000 91 4.01 44.11 3179.0 339.53 0.0289 3209.3 366.00 3209.3 366.00 0.0289
1120 91 4.25 46.75 3560.5 380.27 0.0258 3594.4 409.92 3594.4 409.92 0 0258

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.