High Quality PVC Insulated Aerial Overhead Cable for Rated Voltage of 10kv

High Quality PVC Insulated Aerial Overhead Cable for Rated Voltage of 10kv

High Quality PVC Insulated Aerial Overhead Cable for Rated Voltage of 10kv

JKY, JKTRY, JKLY, JKLHY

Jinyuan

ISO9001, CE, CCC

Overhead Power Tansmission Line,Construction

Round Wire

PVC

PVC

Copper,Aluminum,Alumininum Alloy

Overhead

Stranded

Insulated

100000m2

20 Years

According to Order

Jinyuan

Wooden Drum

JKY, JKTRY, JKLY, JKLHY

Henan, China

8544601200

Product Description

1.Executive standard:
     GB/T14049-2008
2.Application:
      This product is new-type series to transmit electricity in overhead power tansmission line the best choics for construction and transformation of electric network in 10kV transmission line and is the most suitable product safety and maintenance of line and a product.Soft copper core is used leads of transformer.
3.Type and Description:
      Meanings Of Alphabets In Type:
       JK-refer to overhead             LH-alumininum alloy             TR-soft copper conductor
       L-alumininum                         B-natural color insulation     Q-light thin insulation

Type  Description Laying Attention Item
JKY Cu core PVC insulated aerial overhead cable Aerail fixed laying soft Cu core products used as entrance wires of transformers while laying aerial cables keep cables a certain distance from trees
JKTRY Soft Cu core PVC insulated aerial overhead cable
JKLY Al core PVC insulated aerial overhead cable
JKLHY Alumininum alloy core PVC insulated aerial overhead cable

4.Condition of Usage:
1)The rated voltage is 10kV.
2)The temperature should be not less than -20ºC during laying cable.
3)When it is short-circuited (max period is not exceed 5s),the max temperature of cableis:for  XLPEinsulation,250ºC;for HDPE insulation ,150ºC.
4)Max admissible operating temperature for conductor of cable in long-term:for cable with carrying load member,it may be detemined by the max admissible operating temperature of its insulation ;for XLPE insulation,90ºC;for HDPE insulation ,75ºC.
5) Admissible bending radiius should not less than dia.of cylinder in bending test.
5.Technical Parameters

Nominal Cross Section mm2 The Resisrance 20ºC≤Ω/km Conductor Drawing Pressure ≥N
Hard Cu Core  Soft Cu Core Al Core  Alumininum alloy Hard Cu Core  Al Core Alumininum Alloy
10   1.830 3.080        
16   1.150 1.910        
25 0.749 0.727 1.200 1.393 8465 3762 6284
35 0.540 0.524 0.868 1.007 11731 5177 8800
50 0.399 0.387 0.641 0.744 16502 7011 12569
70 0.276 0.268 0.443 0.514 23461 10354 17596
95 0.199 0.268 0.320 0.371 31759 13727 23880
120 0.158 0.153 0.253 0.294 39911 17339 30164
150 0.128 0.206 0.239 49505 21033 37706
185 0.1021 0.164 0.190 61846 26732 46503
240 0.0777 0.125 0.145 79832 34679 60329
300 0.0619 0.100 0.116 99788 43349 75411
400 0.0484 0.0778 0.0904 133040 55707 10548