High Quality Acss/Aw Bare Overhead Conductor

High Quality Acss/Aw Bare Overhead Conductor

High Quality Acss/Aw Bare Overhead Conductor

acss

Bare

Stranded

Overhead

Aluminum

Bare

None

ISO9001, CE

SABS

Henan Jiapu

2000ton/Month

1km

Accord with The Request

SABS, ISO9001-2008, CQC Certificate, CE , SGS

Tianjin, Qingdao, Ningbo, Shanghai, Xiamen

L/C, D/P, D/a ,T/T, M/T, D/D, O/a, C.W.O, C.O.D, C

Jiapu

Wooden Drum or Wooden&Steel Drum

IEC ASTM BS DIN, Any standard

Zhengzhou

7614900000

Product Description

Aluminium Conductor, Aluminum Clad Steel Supported

Construction
ACSS/AW is a composite concentric-lay-stranded conductor. Steel strands form the central core of the conductor with one or more layers of aluminum 1350-0 wire stranded around it. The steel core carries most or all of the mechanical load of the conductor due to the "0" (fully annealed or soft) temper aluminum. Steel core wires are protected from corrosion by an aluminum coating. The aluminum-clad steel core may consist of 7, 19, 37 or more wires. Numerous combinations of aluminum and steel strand and layers are possible.

Features
The AW core, which consists of a thick layer of aluminum (approx. 10% of the nominal wire/radius) over steel, gives ACSS/AW conductors the advantages of standard ACSS along with the light weight and good conductivity of aluminum and the high tensile strength and ruggedness of steel. ACSS/AW can operate continuously at high temperatures (250°C) without damage, allowing for a significant increase in conductor current-carrying capacity. The cross-sections above illustrate some common stranding.

Light weight
Good conductivity
High tensile strength

Specification
Tinde Power’s ACSS/AW conductor meets or exceeds the following ASTM specifications:

B609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes.
B502 Aluminum-Clad Steel Core Wire for Aluminum conductors, Aluminum-Clad Steel Reinforced.
B856 Concentric-Lay-Stranded Aluminum Conductors, Coated Steel Supported (ACSS).
The strandings available are identical to those listed in ASTM specification B232.

BS EN 50182:2001

Code Name Stranding&wire diameter Approx Overall diameter Total area Weight Breaking Load DC Resistance at 20 Current Rating
mm mm mm 2 Kg/km KN Ohm/km A
Box 7/1.85 5.55 18.8 51.4 5.55 1.748 93
Acacia 7/2.08 6.24 23.9 64.9 7.02 1.3828 110
Almond 7/2.34 7.02 30.1 82.2 8.88 1.0926 128
Cedar 7/2.54 7.62 35.5 96.8 10.46 0.9273 132
Deodar 7/2.77 8.31 42.2 115.2 12.44 0.7797 148
Fir 7/2.95 8.85 47.8 130.6 14.11 0.6875 161
Hazel 7/3.30 9.9 59.9 163.4 17.66 0.5494 184
Pine 7/3.61 10.8 71.6 195.6 21.14 0.4591 204
Holly 7/3.91 11.7 84.1 229.5 24.79 0.3913 222
Willow 7/4.04 12.1 89.7 245 26.47 0.3665 233
Oak 7/4.65 13.95 118.9 324.5 35.07 0.2767 272
Mulbery 19/3.18 15.9 150.9 414.3 44.52 0.2192 319
Ash 19/3.48 17.4 180.7 496.1 53.31 0.183 354
Elm 19/3.76 18.8 211 579.2 62.24 0.1568 385
Poplar 37/2.87 20.1 239.4 659.4 70.61 0.1387 414
Sycamore 37/3.23 22.6 303.2 835.2 89.4 0.1095 487
Upas 37/3.53 24.7 362.1 997.5 106.82 0.0917 527
Yew 37/4.06 28.4 479 1319.6 141.31 0.0693 629
Totara 37/4.14 29.42 498.1 1372.1 146.93 0.0666 640
Rubus 61/3.50 31.5 586.9 1622 173.13 0.0567 716
Sorbus 61/3.71 33.4 659.4 1822.5 194.53 0.0505 760
Araucaria 61/4.14 37.3 821.1 2269.5 242.24 0.0406 842
Redwood 61/4.56 41 996.2 2753.2 293.88 0.0334 920