High Quality ABC Service Drop Wire

High Quality ABC Service Drop Wire

High Quality ABC Service Drop Wire

JKLYJ

Insulated

Stranded

Overhead

Aluminum

PVC

XLPE

ISO9001, CE

SABS

Henan Jiapu

Aluminum

None

None

0.6/1kv,10kv

1-4 Cores

ASTM, BS, CSA, DIN

jiapu

Wooden Drum or Wooden&Steel Drum

IEC, ASTM, BS, DIN

Henan, China

4101962331

Product Description

1. Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.

2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop

The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.

3. Detaild Introduction of Service Drop Cable
3.1 Duplex Service Drop
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.

Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

3.2 Triplex Service Drop
Applications
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.

Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

Construction
Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.

Standard:

ASTM B230, B231, B232,B399,B498, ICEA S-76-474 Standard

Code Name

Phase Conductor

Bare Neutral

Approx.Weight

Code Name

Phase Conductor

Bare Neutral

Approx. Weight

Size

Stranding

Insulation Thickness

Size

Stranding

XLPE

PE

Size

Stranding

Insulation Thickness

Size

Stranding

XLPE

PE

AWG

mil

AWG

lbs/1000ft

AWG

mil

AWG

lbs/1000ft

6201 Alloy Neutral Messenger

AAC Neutral Messenger

Bay

6

Solid

45

6

7

145

140.0

Clydesdale

4

Solid

45

4

7

208

201.8

French Coach

6

7/w

45

6

7

155

144.3

Pinto

4

7/w

45

4

7

223

207.9

German Coach

4

Solid

45

4

7

214

208.3

Mustang

2

7/w

45

2

7

333

312.6

Arabian

4

7/w

45

4

7

229

214.4

Criollo

1/0

19/w

60

1/0

7

529

504.5

Belgian

2

7/w

45

2

7

344

323.1

Percheron

2/0

19/w

60

2/0

7

649

620.5

Shetland

1/0

19/w

60

1/0

7

546

521.1

Hanoverian

3/0

19/w

60

3/0

19

799

765.6

Thoroughbred

2/0

19/w

60

2/0

7

670

641.5

Oldenburg

4/0

19/w

60

4/0

19

986

946.7

Trotter

3/0

19/w

60

3/0

7

825

791.8

Lippizaner

336.4

19/w

60

336.4

19

1,546

1,519.2

Walking

4/0

19/w

60

4/0

7

1019

979.7

ACSR Neutral Messenger

Morochuca

6

Solid

45

6

6/1

152

147.4

Grullo

2/0

19/w

60

2/0

6/1

707

678.7

Chola

6

7/w

45

6

6/1

162

151.7

Suffolk

3/0

19/w

60

3/0

6/1

872

838.9

Morgan

4

Solid

45

4

6/1

226

220

Appaloosa

4/0

19/w

60

4/0

6/1

1079

1039.2

Hackney

4

7/w

45

4

6/1

241

226.1

Bronco

336.4

19/w

60

336.4

18/1

1613

1568.2

Palomino

2

7/w

45

2

6/1

362

342.6

Gelding

336.4

19/w

60

4/0

6/1

1548

1494.3

Costena

1/0

19/w

60

1/0

6/1

575

550.6

Note:

(1)Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

(2)Conductor temperature of 90°C for XLP, 75°C for poly; ambient temperatures of 40°C; emissivity 0.9; 2ft./sec/wind in sun.

Tags: , ,