High Quality AAAC with ASTM B399 Standard

High Quality AAAC with ASTM B399 Standard

High Quality AAAC with ASTM B399 Standard

AAAC

Bare

Stranded

Overhead

Aluminum

None

None

ISO9001, CE

SABS

Henan Jiapu

ASTM B399, BS 3242, BS En50183, DIN 48201, IEC 610

2000ton/Month

1km

Accord with The Request

Jiapu

Wooden Drum

IEC, ASTM, DIN, BS, GB, Any standard

Henan, China

7614900000

Product Description

AAAC Conductor with ASTM B399 Standard

Application
Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives AAAC higher resistance to corrosion than ACSR.

Construction
Standard 6201-T81 high strength aluminum conductors, conforming to ASTM Specification B-399, are concentric-lay-stranded, similar in construction and appearance to 1350 grade aluminum conductors. Standard 6210 alloy conductors are similar to other alloy conductors commercially known as Ardival, Aldrey or Almelec. They were developed to fill the need for an economical conductor for overhead applications requiring higher strength than that obtainable with 1350 grade aluminum conductors, but without a steel core. The DC resistance at 20 °C of the 6201-T81 conductors and of the standard ACSR of the same diameter are approximately the same. Conductors of the 6201-T81 alloys are harder and , therefore, have a greater resistance to abrasion than conductors of 1350-H19 grade aluminum.

Specification
AAAC bare conductor meets or exceeds the following ASTM specifications:
B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purposes
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
5pt’>Construction

Workshop

Shipment

FAQ

1. How many years has Henan Jiapu Cable Group been in production?

Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China

2. What kinds of products does Jiapu Cable manufacture?

1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;

2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;

3)PVC Insulated (Flexible ) Wire ;

4) PVC Insulated and Sheathed (Armoured) Power Cable;

5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;

6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;

3. What kind of certifications do you have?

SABS, CE, ISO9001-2000, SGS

4.Which markets do you involve mainly in?

Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.

5. Which standards do you comply with when you produce the electrical wires and cables ?

We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.

6. What is the min.order quantity ?

It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.

7. What is the production capacity per week or per month ?

For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.

8. Do you supply the customers with installation service in foreign country ?

We don’t have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.

Specifications:

Code Name
Area Size & Stranding of ACSR with Equal Diameter No. & Diameter of wires Overall Diameter Weight Nominal Breaking Load Area Stranding and Wire Diameter Approx Overall Diameter Weight Nominal Breaking Load Max.D.C. Resistance
Nominal Actual Nominal Actual
MCM mm 2 AWG or MCM Al/Steel mm mm kg/km kN AWG or MCM mm² mm mm kg/km kN Ω/km
Akron 30.58 15.48 6 6/1 7/1.68 5.04 42.7 4.92 6 13.3 7/1.554 4.67 37 4.22 2.5199
Alton 48.69 24.71 4 6/1 7/2.12 6.35 68.0 7.84 4 21.15 7/1.961 5.89 58 6.71 1.5824
Ames 77.47 39.22 2 6/1 7/2.67 8.02 108 12.45 2 33.63 7/2.474 7.42 93 10.68 0.9942
Azusa 123.3 62.38 1/0 6/1 7/3.37 10.11 172 18.97 1/0 53.48 7/3.119 9.36 148 16.97 0.6256
Anaheim 155.4 78.65 2/0 6/1 7/3.78 11.35 217 23.93 2/0 67.42 7/3.503 10.51 186 20.52 0.4959
Amherst 195.7 99.22 3/0 6/1 7/4.25 12.75 273 30.18 3/0 85.03 7/3.932 11.8 234 25.86 0.3936
Alliance 246.9 125.1 4/0 6/1 7/4.77 14.31 345 38.05 4/0 107.23 7/4.417 13.26 296 32.63 0.3119
Butte 312.8 158.6 266.8 26/7 19/3.26 16.30 437 48.76 250 126.66 19/2.913 14.57 349 38.93 0.2642
Canton 394.5 199.9 336.4 26/7 19/3.66 18.30 551 58.91 300 152.1 19/3.193 15.97 419 46.77 0.2199
Cairo 465.4 235.8 397.5 26/7 19/3.98 19.88 650 69.48 350 177.35 19/3.447 17.24 489 52.25 0.1887
Darien 559.5 283.5 477.0 26/7 19/4.36 21.79 781 83.52 400 202.71 19/3.686 18.43 559 59.74 0.165
Elgin 652.4 330.6 556.5 26/7 19/4.71 23.54 911 97.42 450 228 19/3.909 19.55 629 67.19 0.1467
Flint 740.8 375.3 636.0 26/7 37/3.59 25.16 1035 108.21 500 253.35 19/4.120 20.6 698 74.64 0.1321
Greely 927.2 469.8 795.0 26/7 37/4.02 28.14 1295 135.47 550 278.6 37/3.096 21.67 768 83.8 0.1202
600 303.8 37/3.233 22.63 838 91.38 0.1102
650 329.25 37/3.366 23.56 908 97.94 0.1016
700 354.55 37/3.493 24.45 978 102.2 0.0944
750 380.2 37/3.617 25.32 1049 109.6 0.088
800 405.15 37/3.734 26.14 1117 116.8 0.0826
900 456.16 37/3.962 27.73 1258 131.5 0.0733
1000 506.71 37/4.176 29.23 1399 146.1 0.066