High Performance Aluminum Core XLPE Insulation ABC Cable

High Performance Aluminum Core XLPE Insulation ABC Cable

High Performance Aluminum Core XLPE Insulation ABC Cable

JKLYJ

Insulated

Stranded

Overhead

Aluminum

PVC

XLPE

ISO9001, CE

SABS

Henan Jiapu

None

None

0.6/1kv,10kv

1-4 Cores

Jiapu

Wooden Drums

any one

Henan China

4101962331

Product Description

High Performance Aluminum Core XLPE Insulation ABC Cable

1. Applications
Aerial Bundled cable is used for overhead power transmission and distribution lines with the voltage from 1KV-35KV. Also can be installed in the street with dense trees close to the building site of urban construction.

It consists of copper or aluminum conductor, inner shidleing layer, weather-poof indulation material and outer shidleing layer. It has not only power-transmitting chatacter of power cable, but strong mechanical chatacter of aeria; Cable as well, In compaison with bare, It boasts many advantages such as small span in laying the initiative to choose to use.

2. Standard
GB12527-90 1kv Aerial insulation cable
GB14049-93 10kv Aerial insulation cable

3. Working conditions of aerial insulation power cable
1)Rated voltage: 1kv 10kv

2)The tallest work temperatuie of the cable conductor
XLPE insulation cable temperature +90° C
HDPE insulation cable temperature +75

3)During having a short a short (lasting less than 5 seconds)
The maximum temperature
XLPE insullsted cables is temperature + 250
HDPE insulsted cables is temperature +150

4)During the cable lying the ambient temperature must be above temperature +20

5)Bending radius allowance of the cable

A)1kv aeria; Insulation power cable
It shouldbe no less than 4D for cable with outer diameter less than 25mm
It should be no less than 6D for cable with outer diameter of 25 mmor more

B)10kv aerial insulation power cable
Single core cable20(D+d )± 5%mm
Multi-core cable: 15(D+d) ± 5%mm
Formula insiide: D-Actual cable outer diameter:
D-Actual conductor outer diameter

Specifiaction:

(1)Self-supporting

Phase

Phase

Phase

Approx.Overall Diameter

Max. D.C. Resistance of Conductor at 20ºC

AAC+UV-XLPE

Compact Conductor

UV-XLPE Insulation

No.X Normal Cross Section of Cores

No.of Al Wires

Overall Diameter

Normal Thickness

Min.

Diameter

No. X mm2

mm

mm

mm

mm

mm

ohm/km

1 X 10

7

4.05

1.0

0.8

6.05

6.05

3.08

1 X 16

7

4.8

1.2

0.98

7.2

7.20

1.91

1 X 25

7

6

1.2

0.98

8.4

8.40

1.20

1 X 35

7

7.0

1.4

1.16

9.8

9.80

0.868

1 X 50

7

8.3

1.4

1.16

11.1

11.10

0.641

1 X 70

19

9.8

1.4

1.16

12.6

12.60

0.443

1 X 95

19

11.6

1.6

1.34

14.8

14.80

0.320

1 X 120

19

13

1.6

1.34

16.2

16.20

0.253

1 X 150

19

14.6

1.8

1.52

18.2

18.20

0.206

1 X 185

36

16.2

2.0

1.70

20.2

20.20

0.164

1 X 240

36

18.4

2.2

1.88

22.8

22.80

0.125

2 X 10

7

4.05

1.0

0.8

6.05

12.10

3.08

2 X 16

7

4.8

1.2

0.98

7.2

14.40

1.91

2 X 25

7

6

1.2

0.98

8.4

16.80

1.20

2 X 35

7

7.0

1.4

1.16

9.8

19.60

0.868

2 X 50

7

8.3

1.4

1.16

11.1

22.20

0.641

2 X 70

19

9.8

1.4

1.16

12.6

25.20

0.443

2 X 95

19

11.6

1.6

1.34

14.8

29.60

0.320

2 X 120

19

13

1.6

1.34

16.2

32.40

0.253

2 X 150

19

14.6

1.8

1.52

18.2

36.40

0.206

2 X 185

36

16.2

2.0

1.70

20.2

40.40

0.164

2 X 240

36

18.4

2.2

1.88

22.8

45.60

0.125

3 X 10

7

4.05

1.0

0.8

6.05

13.07

3.08

3 X 16

7

4.8

1.2

0.98

7.2

15.55

1.91

3 X 25

7

6

1.2

0.98

8.4

18.14

1.20

3 X 35

7

7.0

1.4

1.16

9.8

21.17

0.868

3 X 50

7

8.3

1.4

1.16

11.1

23.98

0.641

3 X 70

19

9.8

1.4

1.16

12.6

27.22

0.443

3 X 95

19

11.6

1.6

1.34

14.8

31.97

0.320

3 X 120

19

13

1.6

1.34

16.2

34.99

0.253

3 X 150

19

14.6

1.8

1.52

18.2

39.31

0.206

3 X 185

36

16.2

2.0

1.70

20.2

43.63

0.164

3 X 240

36

18.4

2.2

1.88

22.8

49.25

0.125

4 X 10

7

4.05

1.0

0.8

6.05

14.64

3.08

4 X 16

7

4.8

1.2

0.98

7.2

17.42

1.91

4 X 25

7

6

1.2

0.98

8.4

20.33

1.20

4 X 35

7

7.0

1.4

1.16

9.8

23.72

0.868

4 X 50

7

8.3

1.4

1.16

11.1

26.86

0.641

4 X 70

19

9.8

1.4

1.16

12.6

30.49

0.443

4 X 95

19

11.6

1.6

1.34

14.8

35.82

0.320

4 X 120

19

13

1.6

1.34

16.2

39.20

0.253

4 X 150

19

14.6

1.8

1.52

18.2

44.04

0.206

4 X 185

36

16.2

2.0

1.70

20.2

48.88

0.164

4 X 240

36

18.4

2.2

1.88

22.8

55.18

0.125

(2) Phase + Neutral

Phase

Neutral

Phase

Neutral

Approx.Overall Diameter

Max. D.C. Resistance of Conductor at 20ºC

AAC+UV-XLPE

AAAC

Compact Conductor

UV-XLPE Insulation

Conductor

Phase

Neutral

No.X Normal Cross Section of Cores

No.X Normal Cross Section of Cores

No.of Al.Wire

Overall Dia.

Normal Thickness

Min.

No./Dia. of Al Alloy Wire

No. X mm2

No. X mm2

mm

mm

Min.

No./mm

mm

ohm/km

ohm/km

1 X 16

1 X 16

7

4.8

1.2

0.98

7/1.70

12.30

1.91

2.217

1 X 25

1 X 25

7

6

1.2

0.98

7/2.10

14.70

1.20

1.393

1 X 35

1 X 35

7

7.0

1.4

1.16

7/2.50

17.30

0.868

1.007

1 X 50

1 X 50

7

8.3

1.4

1.16

7/3.00

20.10

0.641

0.744

1 X 70

1 X 70

19

9.8

1.4

1.16

7/3.50

23.10

0.443

0.514

1 X 95

1 X 95

19

11.6

1.6

1.34

19/2.50

27.30

0.320

0.371

1 X 120

1 X 120

19

13

1.6

1.34

19/2.80

30.20

0.253

0.294

1 X 150

1 X 150

19

14.6

1.8

1.52

37/2.25

33.95

0.206

0.239

1 X 185

1 X 185

36

16.2

2.0

1.70

37/2.50

37.70

0.164

0.190

1 X 240

1 X 240

36

18.4

2.2

1.88

61/2.25

43.05

0.125

0.145

2 X 16

1 X 16

7

4.8

1.2

0.98

7/1.70

14.04

1.91

2.217

2 X 25

1 X 25

7

6

1.2

0.98

7/2.10

16.63

1.20

1.393

2 X 35

1 X 35

7

7.0

1.4

1.16

7/2.50

19.51

0.868

1.007

2 X 50

1 X 50

7

8.3

1.4

1.16

7/3.00

22.46

0.641

0.744

2 X 70

1 X 70

19

9.8

1.4

1.16

7/3.50

25.70

0.443

0.514

2 X 95

1 X 95

19

11.6

1.6

1.34

19/2.50

30.31

0.320

0.371

2 X 120

1 X 120

19

13

1.6

1.34

19/2.80

33.41

0.253

0.294

2 X 150

1 X 150

19

14.6

1.8

1.52

37/2.25

37.55

0.206

0.239

2 X 185

1 X 185

36

16.2

2.0

1.70

37/2.50

41.69

0.164

0.190

2 X 240

1 X 240

36

18.4

2.2

1.88

61/2.25

47.41

0.125

0.145

3 X 16

1 X 16

7

4.8

1.2

0.98

7/1.70

16.15

1.91

2.217

3 X 25

1 X 25

7

6

1.2

0.98

7/2.10

19.06

1.20

1.393

3 X 35

1 X 35

7

7.0

1.4

1.16

7/2.50

22.32

0.868

1.007

3 X 50

1 X 50

7

8.3

1.4

1.16

7/3.00

25.59

0.641

0.744

3 X 70

1 X 70

19

9.8

1.4

1.16

7/3.50

29.22

0.443

0.514

3 X 95

1 X 95

19

11.6

1.6

1.34

19/2.50

34.42

0.320

0.371

3 X 120

1 X 120

19

13

1.6

1.34

19/2.80

37.87

0.253

0.294

3 X 150

1 X 150

19

14.6

1.8

1.52

37/2.25

42.56

0.206

0.239

3 X 185

1 X 185

36

16.2

2.0

1.70

37/2.50

47.25

0.164

0.190

3 X 240

1 X 240

36

18.4

2.2

1.88

61/2.25

53.63

0.125

0.145

(3) Phase + Neutral + Service Connection

Phase

Neutral

Service Connection

Phase

Neutral

Service Connection

Approx.Overall Diameter of Bundled Cable

AAC+UV-XLPE

AAAC+UV-XLPE

AAC+UV-XLPE

Conductor

UV-XLPE

Conductor

UV-XLPE

Compact Conductor

UV-XLPE

No.X Normal Cross Section of Cores

No.X Normal Cross Section of Cores

No.X Normal Cross Section of Cores

No. of Al. Wire

Overall Dia.

Normal
Thickness

No./Dia. of Al. Wire

Normal
Thickness

No. of Al. Wire

Overall Dia.

Normal
Thickness

No. X mm2

No. X mm2

No. X mm2

mm

mm

mm

mm

No./mm

mm

mm

mm

3 X 16

1 X 50

1 X 16

7

4.8

1.2

7/3.0

1.4

7

4.8

1.2

26.2

3 X 25

1 X 50

1 X 16

7

6

1.2

7/3.0

1.4

7

4.8

1.2

28.6

3 X 35

1 X 50

1 X 16

7

7.0

1.4

7/3.0

1.4

7

4.8

1.2

31.4

3 X 50

1 X 50

1 X 16

7

8.3

1.4

7/3.0

1.4

7

4.8

1.2

34

3 X 70

1 X 50

1 X 16

19

9.8

1.4

7/3.0

1.4

7

4.8

1.2

37

3 X 95

1 X 50

1 X 16

19

11.6

1.6

7/3.0

1.4

7

4.8

1.2

41.4

3 X 120

1 X 50

1 X 16

19

13

1.6

7/3.0

1.4

7

4.8

1.2

44.2

3 X 16

1 X 50

2 X 16

7

4.8

1.2

7/3.0

1.4

7

4.8

1.2

26.2

3 X 25

1 X 50

2 X 16

7

6

1.2

7/3.0

1.4

7

4.8

1.2

28.6

3 X 35

1 X 50

2 X 16

7

7.0

1.4

7/3.0

1.4

7

4.8

1.2

31.4

3 X 50

1 X 50

2 X 16

7

8.3

1.4

7/3.0

1.4

7

4.8

1.2

34

3 X 70

1 X 50

2 X 16

19

9.8

1.4

7/3.0

1.4

7

4.8

1.2

37

3 X 95

1 X 50

2 X 16

19

11.6

1.6

7/3.0

1.4

7

4.8

1.2

41.4

3 X 120

1 X 50

2 X 16

19

13

1.6

7/3.0

1.4

7

4.8

1.2

44.2