H07V-K PVC Insulated Conductor with Fine Wired Stranded

H07V-K PVC Insulated Conductor with Fine Wired Stranded

H07V-K PVC Insulated Conductor with Fine Wired Stranded

H07V-K

Insulated

Stranded

Heating, Underground

Copper

PVC

PVC

Round Wire

Heating and Underground

ISO9001, CE, CCC, RoHS

Product Certificate(Son)

Jytop

JYTOP

Packed in 100m Coils

as per popular standards or clients's requirement

Zhengzhou, China

8544492100

Product Description

H07V-K PVC INSULATED CONDUCTOR WITH FINE WIRED STRANDED

—PVC Insulated Copper Wire, Earth Wire

Application:
H07V-K PVC insulated conductor with fine wired stranded is used for laying in electric-installation tubes, under and on plaster installation in dry rooms and in closed installation conduits. Direct laying in cable guides is not permitted. Also applied for internal wiring of distribution and switching boxes equipment, same as for protective laying for lighting of nominal voltage up to 1000 V alternating current, or up to 750 V direct current against earth.

Standards:
BS6004
IEC 60227-3
HRN HD 21.3 S3
DIN VDE 0281 part 3

Conductor: bare copper conductor, fine wired stranded, class 5. acc. to IEC 60228 / HD 383 / DIN VDE 0295
Insulation: PVC compound TI1 acc. to IEC 60227-3 / HD 21.3 S3 / DIN VDE 00281 part 3
Conductor colour acc. to IEC 60446 i.e. EN 60446 (corresponding to DIN VDE 0293)

Technical data:

Temperature range:
during installation: +5 °C up to +70 °C
fixed installed: -30 °C up to +70 °C
at short circuit of max. 5 s: up to 160 °C
ambient temperature at storage: up to 40 °C
Nominal voltage: Uο/U = 450/750 V
Test voltage: 2500 V
Minimal inner bending radius: 4D for D < 8 mm
5D for 8 – 12 mm
6D for D > 12 mm
Behaviour in fire: IEC 60332-1

NOTE:
If you want to know more details about this H07V-K PVC insulated conductor with fine wired stranded, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.

Dimensions – conductor cross-section Construction of individual conductor External diameter Insulation thickness Conductor resistance at 20 °C Specific. el. resistance of insulation at 70°C Cu weight Cable weight Packing*
nominal min-max. nominal max min. approx.
mm² n x mm mm mm Ω/km MΩkm kg/km kg/km
1,5 30 x 0,25 2,8 – 03,4 0,7 13,3 0,0100 14,4 20 c.100, c.200
2,5 50 x 0,25 3,4 – 04,1 0,8 7,98 0,0095 24,0 32 c.100
4 56 x 0,30 3,9 – 04,8 0,8 4,95 0,0078 38,4 46 c.100
6 84 x 0,30 4,4 – 05,3 0,8 3,30 0,0068 57,6 65 c.100
10 80 x 0,40 5,7 – 06,8 1,0 1,91 0,0065 96,0 115 c.100
16 128 x 0,40 6,7 – 08,1 1,0 1,21 0,0053 153,6 170 c.100
25 200 x 0,40 8,4 – 10,2 1,2 0,780 0,0050 240 260 CUT
35 280 x 0,40 9,7 – 11,7 1,2 0,554 0,0043 336 360 CUT
50 400 x 0,40 11,5 – 13,9 1,4 0,386 0,0042 480 515 CUT
70 356 x 0,50 13,2 – 16,0 1,4 0,272 0,0036 672 710 CUT
95 485 x 0,50 15,1 – 18,2 1,6 0,206 0,0036 912 940 CUT
120 614 x 0,50 16,7 – 20,2 1,6 0,161 0,0032 1152 1180 CUT
150 765 x 0,50 18,6 – 22,5 1,8 0,129 0,0032 1440 1600 CUT
185 944 x 0,50 20,6 – 24,9 2,0 0,106 0,0032 1776 2100 CUT
240 1225 x 0,50 23,5 – 28,4 2,2 0,0801 0,0031 2304 3015 CUT

Packing: c.100 = coil 100 m, c.200 = coil 200 m CUT= cable in different lengths on drum or reel, possible cutting at required length