H07V-K, H07V-U, H07V-R 450/750V Copper PVC Insulating Sheath Wire and Cable

H07V-K, H07V-U, H07V-R 450/750V Copper PVC Insulating Sheath Wire and Cable

H07V-K, H07V-U, H07V-R 450/750V Copper PVC Insulating Sheath Wire and Cable

H07V-K, H07V-U, H07V-R

Construction, Underground, Power Station

PVC-Insulated Conductors for Fixed Installations

Low and Medium Voltage Cable

AC Cable

PVC

PVC

Round Wire

Solid or Strand Copper

ISO, CCC, CE, VDE

H07V-K,H07V-U,H07V-R

Jytop

Ts En 50525-2-31, BS En 50525-2-31,VDE 281

CCC/Ce

Black, Red

70°c

Cross Section< 30

JYTOP

Drums or as Your Request

1x10mm2, 1x120mm2

Henan, Zhengzhou

8544492100

Product Description

H07V-K,H07V-U,H07V-R 450/750V Copper PVC insulating sheath wire and cable

Application Area

In dry rooms, switching and distribution panels, for laying in conduit on and under plaster and/or on insulating supports above plaster.

Technical Data

Temperature range:
during installation: +5 °C up to +70 °C
fixed installed: -30 °C up to +70 °C
at short circuit of max. 5 s: up to 160 °C
ambient temperature at storage: up to 40 °C
Nominal voltage: Uο/U = 450/750 V
Test voltage: 2500 V
Minimal inner bending radius: 4D for D < 8 mm
5D for 8 – 12mm
6D for D > 12 mm
Behaviour in fire: IEC 60332-1

Construction of 450/750 V PVC Insulated, Non-Sheathed Single Core Cables

1. letken : EN 60228 Snf 1-2 Bakr
2. zole : PVC, TS 9756, (HD 21.1.S4) TI1

Applicable Standards

TS EN 50525-2-31, BS EN 50525-2-31,VDE 281.

Parameter of H07V-K,H07V-U,H07V-R CABLE

Dimensions – conductor cross-section Construction of individual conductor External diameter Insulation thickness Conductor resistance at 20 °C Specific. el. resistance of insulation at 70°C Cu weight Cable weight Packing*
nominal min-max. nominal max. min. approx.
mm² n x mm mm mm Ω/km MΩkm kg/km kg/km
10 7 x 1,35 5,6 – 06,7 1,0 1,83 0,0067 96 120 c.100
16 7 x 1,70 6,4 – 07,8 1,0 1,150 0,0056 153,6 175 c.100
25 7 x 2,13 8,1 – 09,7 1,2 0,727 0,0053 240 275 c.50, CUT
35 7 x 2,52 9,0 – 10,9 1,2 0,524 0,0046 336 370 c.50, CUT
50 19 x 1,83 10,6 – 12,8 1,4 0,387 0,0046 480 500 CUT
70 19 x 2,17 12,1 – 14,6 1,4 0,268 0,0040 672 710 CUT
95 19 x 2,52 14,1 – 17,1 1,6 0,193 0,0039 912 970 CUT
120 37 x 2,03 15,6 – 18,8 1,6 0,153 0,0035 1152 1200 CUT
150 37 x 2,27 17,3 – 20,9 1,8 0,124 0,0035 1440 1470 CUT

*) Packing: c.50 = coil 50 m, c.100 = coil 100 m, CUT = cable in different lengths on drum or reel, possible cutting at required length

Advantages:
a. Excellent electric and mechanical characteristics
b. Best Resistance chemical corrosion and heat-ageing,environment stress and flame-retardant
c. Simple in structure
d. Convenient to use
e. Light weight,perfect bending properties

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.