Flexible Rubber Welding Cable with Low Voltage

Flexible Rubber Welding Cable with Low Voltage

Flexible Rubber Welding Cable with Low Voltage

Rubber cable

Insulated

Stranded

Heating, Underground

Copper

EPDM

Rubber

Round Wire

Industry

ISO9001, CE, CCC

Jytop

1kv

Annealed Copper

PVC

EPDM

Ce, ISO

Yes

Drum

as Request

2000m

T/T or L/C

JYTOP

Packed in 500m Coils or in Wooden Reels

as per popular standards or clients's requirement

Zhengzhou, China

8544492100

Product Description

Welding Cable (Welding Wire) meets or exceeds the requirements of all international standards like ASTM,IEC,DIN,BS,AS,CSA,NFC,SS,etc. in addition, we also accept OEM service to meet your special request.
Welding Wire / Welding Cables Construction:
Conductor: Fully annealed stranded bare copper per ASTM B-172.
Jacket: Black or Red Ethylene Propylene Diene Monomer Rubber (EPDM)
Additional Jacket Colors: Also available in orange, yellow, blue or green
Weld Wire Applications:
1). Secondary voltage resistance welding leads.
2). Power supply applications not exceeding 600 volts A.C.
3). Battery Cable
4). Welding
Weld Wire Features:
1). Weld Wire is resistant to cuts, tears and abrasion in addition to moisture.
2). Welding Wire offers good color retention along with great flexibility.
3). Welding Wire / Welding Cable Options:
4). Zero Halogen EP Jacket
5). UL 600V CPE 90°C
6). CSA Approved Welding Wire
7). Featuring stranded bare copper and available in sizes 6 AWG up to 500 MCM, welding cable is rated to 600V rms max and suitable for us from -50°C to 105°C.
Main Technical Date; Welding Cables to IEC 60245 standard :

Nominal section area(mm2) No./diameter of stranding(mm) Nominal sheath thickness (mm) Overall diameter(mm) Max. conductor resistance at 20ºC(Ω/km)
Min. Max. Without tinned With tinned
10 322/0.20 1.8 7.5 9.7 1.91 1.95
16 513/0.20 2.0 9.2 11.5 1.16 1.19
25 798/0.20 2.0 10.5 13.0 0.758 0.780
35 1121/0.20 2.0 11.5 14.5 0.536 0.552
50 1596/0.20 2.2 13.5 17.0 0.379 0.390
70 2214/0.20 2.4 15.0 19.5 0.268 0.276
95 2297/0.20 2.6 17.0 22.0 0.198 0.204
120 1702/0.30 2.8 19.0 24.0 0.161 0.164
150 2135/0.30 3.0 21.0 27.0 0.129 0.132
185 1443/0.40 3.2 22.0 29.0 0.106 0.108
240 1908/0.40 3.8 25.0 35.0 0.0801 0.0817

Welding Cables to ASTM Standard :

Size (AWG) Nominal stranding Nominal overall diameter Approx. net weight (LBS/1000ft) Max. conductor resistance at 20ºC(Ω/km)
AWG mm inch mm
6 259/30 259/0.254 0.430 10.92 152 1.33
4 418/30 418/0.254 0.475 12.07 215 0.84
2 646/30 646/0.254 0.540 13.72 296 0.53
1 836/30 836/0.254 0.580 14.73 360 0.42
1/0 1032/30 1032/0.254 0.615 15.62 424 0.33
2/0 1290/30 1290/0.254 0.655 16.64 513 0.26
3/0 1672/30 1672/0.254 0.720 18.29 644 0.21
4/0 2066/30 2066/0.254 0.780 19.81 824 0.17