NHA(B)-VV

Insulated

Stranded

Fire Retardant

Copper

PVC

PVC

Round Wire

Flame Retardant

ISO9001, CE, UL, CCC

Yifang

2.5-185mm2

Yifang Cable

Wooden Drum or Wooden-Steel Drum

CE SABS RoHS SGS UL CCC

Zhengzhou, China

8544492100

Product Description


Fire-Retardant Power Cable, Flame resistance cable

1). Application
The cables are designed for fixed installation, for 0.6/1kV, for power transmission and distribution equipments where fire retardatio is requested.

2). Number of cores: 1, 2, 3, 4, 3+1, 3+2;

3). Nom. Coress section range: 2.5~185mm2

4). Operating characteristic

A. AC Rated voltage Uo/U is 0.6/1kV.
B. Testing flame temperature:
Cateaoty A is 950~1000 degree. Cateaoty B is 750~ 800 degree.
C. Permissive continuous working temperature of conductor of PVC, PE insulated cable is no more than 70 degree, and permissive continuous working temperature of conductor of XPLE is no more than 90 degree.
D. The lowest ambient temperature of cable installatio is 0degree.
E. Min. Bending radius of cable installation is:
Non-armoured cable 10Dmm;
Armoured cable 12Dmm.
In the formula: D-actual external diameter of cable, mm

Type Description Application
NHA(B)-VV Copper core PVC insulated and sheathed fire-retarding control cable For fixed instaliation laying indoors,in trenches sand ducts.
NHA(B)-VV22 copper core PVC insulated and sheathed fire-retarding control cable with steel tape armour For fixed instaliation laying indoors,in trenches and ducts where heavire mechanic force is withstood
NHA(B)-YJV copper core XLPE insulated and PVC sheathed fire-retarding control cable with steel armour For fixed instaliation laying indoors,in trenches sand ducts.
NHA(B)-YJV22 copper core XLPE insulated and PVC sheathed fire -retarding control cable with steel armour For fixed instaliation laying indoors,in trenches and ducts where heavire mechanic force is withstood
NHA(B)-YV copper core PE insulated and PVC sheathed fire-retarding control cable For fixed instaliation laying indoors,in trenches sand ducts.
NHA(B)-YV22 copper core PE insulated and PVC sheathed fire-retarding control cable with steel tape armour For fixed instaliation laying indoors,in trenches and ducts where heavire mechanic force is withstood