Fire retardant EXAV-F2 3×16 + 1×10 underground Armoured power cables

Description
Reinforced energy cables for underground household and industrial where there is a risk of mechanical damage. Non-fire spreading (F2)

STANDARDS
National: NBN HD 603 Part 6 / Sect.E
DESCRIPTION
DESCRIPTION
White copper core solid (Class 1) or fused together (Class 2)
XLPE conductor insulation (X)
Safety circuit made of bare copper wires (*)
Steel bands or wires (A)
PVC jacket (V) – color: black
(*) Suitable as earthing for conductors up to and including 6 mm²

COLOR CODE
2 x: blue, brown
3 x: brown, black, gray
3G: green / yellow, blue, brown
3 + 1 x: brown, black, gray + blue
3 + 1 G: brown black, gray + green / yellow
4 x: blue, brown, black, gray
4 G: green / yellow, brown, black, gray

INSTALLATION
In cable channel
In tube
Underground with or without protection
In open air
In industry
In homes

CONSTRUCTION CHARACTERISTICS

Composition conductor Copper Conductor flexibility class 2
Conductor shape Round, joined together
Insulation XLPE
Reinforcement Steel tape
Outer jacket PVC

MEASURING CHARACTERISTICS

Number of conductors 4
Diameter conductor 16mm2
Average thickness of the insulation (mm) 0.7mm
Thickness of the steel tape 0.5mm
Section of the reduced neutral 10mm2
Approximate weight 1260kg/km

ELECTRIC CHARACTERISTICS

Nominal voltage Uo / U (Um) 0.6 / 1 kV
Operating voltage 1kV
Permissible current in open air 100A
Permissible current (underground) 120A
Ohmic resistance of the armament 2.0 Ohm / km

USE CHARACTERISTICS
Chemical resistance Average
Non-fire-spreading: NBN C 30-004-F2
Maximum conductor temperature in operation: 90 ° C
Operating temperature, range: -5 .. 60 ° C

Vibration resistance Average
Bending radius at placement: 15 (xD)
Minimum temperature at installation: 5 ° C

 