Fire Resistant Screened Control Cable

Fire Resistant Screened Control Cable

Fire Resistant Screened Control Cable

Insulated

Stranded

Underground

Copper

PVC

XLPE

Round Wire

Flame Retardant

ISO9001, CE, CCC

Jinshui

JINSHUI

Drum, Reel

CE, SGS, CCC, ISO

Zhengzhou Henan

Product Description


Fire Resistant Screened Control Cable

Description(Features) of Fire Resistant Screened Control Cable

1.Direct-current resistance:20ºC, 0.4mm copper wire, less than or equal to148Ω/km ,0.5mm copper wire,less than or equal to 95Ω/km.
2. Insulation dielectric strength:Between the conductors, there is No breakdown within 1min 1kv, Conductor and shield will not be broken within1min 3kv.
3. insulation resistance:Each conductor and the rest of the grounding line core, control cable is more than 10000 m Ω. Km, more than 3000 m Ω HYAT cable. km.
4.Operating capacitance:average value is 52±2nF/km
5. far-end crosstalk ratio:150 KHZ specified when the combination of the average power is greater than 69 db/km.

Technical Parameters(Specification) of Fire Resistant Screened Control Cable

Rated Voltage: 450/750V Control cable specification .
The long-term working temperature of the conductor wire core is from 70 ºC to 95 ºC, while the laying temperature is not lower than 0 ºC.
The permissible bending radius of the cable as below:
No-armored cable should be not less than 6 times of cable diameter;
Armored or copper tape screened cable should be not less than 12 times of cable diameter;
Shielding flexible cable, not less than 6 times of cable diameter
Control cable refers to equipment instrument power/signal control
On behalf of the model:KVV KYJV/other instrument line and so on
executive standard:GB/T 9330-2008.Flame retardant cable should also be in accordance with the technical conditions of the IEC337-8 standard.

Control cable specification of Fire Resistant Screened Control Cable

Model Name VoltageV Number of cores Cross-sectional
area mm2
Range of application
KVV Copper core PVC insulated PVC
sheathed cable
450/750 4-37 0.75-10 For laying indoors,
in cable trench, pipelines
and other fixed occasion
KVV22 Copper core PVC insulated PVC
sheathed steel tape armored cable
450/750 4-37 0.75-10 For laying indoors,
in cable trench,
directly buried
pipeline and other
fixed occasion,
also can bear larger
external mechanical forces
KVVP Flame retardant copper core PVC
insulated PVC sheathed cable
450/750 4-37 0.75-10 For laying indoors,
in cable trench, pipelines,
etc, and somewhere that
need fixed installation
KVVR Soft copper core PVC insulated and
sheathed control cable
450/750 4-37 0.75-10 For laying indoors,
where there is a requirement
for mobile
KVVRP Copper core PVC insulated PVC
sheathed braided shielding control cable
450/750 4-37 0.75-10 For laying indoors, where
there
is a requirement for mobile
screen
ZRKVV Flame retardant copper core PVC insulated
PVC sheathed cable
450/750 4-37 0.75-10 For laying indoors, in cable
trench, pipe fixed occasion
where demands such as
flame
retardant
ZRKVV22 Flame retardant copper core PVC insulated
PVC sheathed woven tape armored
450/750 4-37 0.75-10 For laying indoors, in cable
trench, pipes, burying and
etc. There is a requirement
for flame retardant can bear
external mechanical forces
larger fixed occasion

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.