Fire-Resistance Copper Conductor PVC Insulated and Sheathed Electric Wire Cable
Product Description
1. Standard: IEC60227, HD22.4, NFC-32-12-4.
2. Voltage: 450/750V, 300/500V,300/300V
3. Conductor: Copper
4. Construction: Solid, Stranded wires, flexible
5. Numer of Cores: single core, two cores, 3 cores, multi-cores,
6. Material of insulation: PVC,EPR.
7. Insulation: PVC
8. Cross Section area of conductor: 0.5mm2, 1mm2, 2mm2, 1.5mm2, 6mm2, 10mm2……….300mm2
Type | Name |
BV | Copper conductor PVC insulated cable |
BVR | Copper conductor PVC insulated flexible cable |
BVV | Copper conductor PVC insulated PVC sheathed round cable |
BVVB | Copper conductor PVC insulated PVC sheathed flat cable |
RVS | Copper conductor PVC insulated stranded cable for flexible connecting |
Structure of Product
1.Conductor
2.Insulation
3.Sheath
Application
It applies to electrical appliance, instrument and telecom device with rated voltage up to and including 450/750V.
The main features of the flame retardant PVC cable or wire is hard to get fair or that the continuous burning of cables is very limited when it is on fire. It applies to the places with special demands for flame retardant property. Flame retardant cable is classified as class A, B or C. Among the 3 classes, class A is the best in aspect of flame retardance.
Fire-resistance cable can operate normally for some time when it is burning except that it can transmit electrical power under normal condition. It is used in the places with special demands for fire resistance property.
The Main Features
1. Rated voltage U0/U is 450/750V, 300/500V, or 300/300V.
2. Permissible continuous working temperature of cable conductor
–for type of cable RV-90 and BV-90, the temperature should be not more than 90ºC
–for others, the temperature should be not more than 70ºC.
3. Ambient temperature should be not less than 0ºC, and permissible bending radius of cable for fixed connecting should be as follows during installation.
4. Flame retardant cable should pass the test of bunched cables or wires under fire conditions which is described in the standards of GB/T18380.3-2001.
5. Fire resistant cable should pass the test of fire resistant stipulated in the standards of GB/T19216.21-2003.
Key Technical Parameter
60227 IEC 01(BV) GB/T5023-2008
Nominal cross- section mm2 |
Conductor Type |
Upper limit Of O.D. mm |
Max.D.C. resistance at 20ºC Ω/km |
Min.insulation resistance at 70ºC MΩ·km |
Approx. ampacity A |
Reference weight of cable kg/km |
1.50 | 1 | 3.2 | 12.1 | 0.011 | 25 | 20.0 |
1.50 | 2 | 3.3 | 12.1 | 0.010 | 25 | 21.5 |
2.50 | 1 | 3.9 | 7.41 | 0.010 | 34 | 31.8 |
2.50 | 2 | 4.0 | 7.41 | 0.009 | 34 | 34.8 |
4.00 | 1 | 4.4 | 4.61 | 0.0085 | 44 | 46.8 |
4.00 | 2 | 4.6 | 4.61 | 0.0077 | 44 | 50.3 |
6.00 | 1 | 5.0 | 3.08 | 0.0070 | 58 | 66.50 |
6.00 | 2 | 5.2 | 3.08 | 0.0065 | 58 | 71.00 |
10 | 2 | 6.7 | 1.83 | 0.0065 | 79 | 116.0 |
16 | 2 | 7.8 | 1.15 | 0.0050 | 111 | 180 |
25 | 2 | 9.7 | 0.727 | 0.0050 | 146 | 277 |
35 | 2 | 10.9 | 0.524 | 0.0040 | 180 | 375 |
50 | 2 | 12.8 | 0.387 | 0.0045 | 282 | 536 |
70 | 2 | 14.6 | 0.268 | 0.0035 | 281 | 706 |
95 | 2 | 17.1 | 0.193 | 0.0035 | 344 | 977 |
120 | 2 | 18.8 | 0.153 | 0.0032 | 397 | 1231 |
150 | 2 | 20.9 | 0.124 | 0.0032 | 456 | 1503 |
185 | 2 | 23.3 | 0.0991 | 0.0032 | 519 | 1870 |
240 | 2 | 26.6 | 0.0754 | 0.0032 | 592 | 2457 |
300 | 2 | 29.6 | 0.0601 | 0.0030 | 685 | 3053 |
400 | 2 | 33.2 | 0.0470 | 0.0028 | 799 | 3948 |
Our Company
Factory & Wokshop
Certificates
Customers
- Next: Low Voltage XLPE/PVC Insulated Overhead Aluminium Cable, Aerial Bundled Cable for Power Transmission
- Previous: Copper/Aluminum Conductor PVC Insulated PVC Sheathed Electrical Wire Cable for Home and Office
Contact us
Similar Or Related
-
10X1.5mm2 Flame Retardant Copper Tape Screen Steel Tape Armored PVC Sheathed Control Cable 0.6/1kV
-
0.3/0.5kV 4X4mm2 Copper Wire Braiding PVC Insulation Low Voltage Control Power Cable
-
24X2.5mm2 XLPE Insulated Steel Tape Armoured Control/Instrumentation Cable IEC 60502-1
-
Low Voltage Single Core Power Cable 1X300 mm2 N2XCH CU/XLPE/CWS/LSF 0.6/1kV
-
Fire-Resistance Copper Conductor PVC Insulated and Sheathed Electric Wire Cable