Electrical Insulated Cable for Building Wire
Product Description
Standard
Basic design to BS 7870 / TNB Specification(IEC 60502) / HD 626 S1 / NFC 33-209 / AS/NZS 3560-1 standards
Construction
Conductor | Aluminium conductor, round stranded compressed (RM). |
Insulation | XPLE compound, UV-resistant. |
Core Identification | 1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm² and a minimum of 16 ribs for cores above 50 mm². In the case of five core bundles the surface of the protective core should be smooth. |
1. Operating Characteristics
Rated voltage: 0.6/1(1.2)kV
Max. Permissible continuous operating temperature of conductor: 90 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed: 250 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For multi-core cable: Not less than 15 times of the diameter of cable
2. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or in conduit, unable to bear external mechanical force.
Specifcation :
Cable size (sq.mm) |
Conductor type | Nominal thickness of XLPE insulation(mm) | Nominal thickness of PVC or PE sheath(mm) | Approx. cable overall diameter (mm) | Max. D.C resistance @ 20 0 C (Ω/km) |
4×1.5 | RE or RM | 0.7 | 1.8 | 10.5 | 12.1 |
4×2.5 | RE or RM | 0.7 | 1.8 | 11.5 | 7.41 |
4×4 | RE or RM | 0.7 | 1.8 | 12.6 | 4.61 |
4×6 | RE or RM | 0.7 | 1.8 | 13.8 | 3.08 |
4×10 | RM | 0.7 | 1.8 | 16.9 | 1.83 |
4×16 | RM | 0.7 | 1.8 | 19.5 | 1.15 |
4×25 | SM | 0.9 | 1.8 | 21.3 | 0.727 |
4×35 | SM | 0.9 | 1.8 | 23.4 | 0.524 |
4×50 | SM | 1.0 | 1.9 | 26.8 | 0.387 |
4×70 | SM | 1.1 | 2.0 | 30.6 | 0.268 |
4×95 | SM | 1.1 | 2.1 | 34.9 | 0.193 |
4×120 | SM | 1.2 | 2.3 | 38.4 | 0.153 |
4×150 | SM | 1.4 | 2.4 | 42.5 | 0.124 |
4×185 | SM | 1.6 | 2.6 | 47.4 | 0.0991 |
4×240 | SM | 1.7 | 2.8 | 53.4 | 0.0754 |
4×300 | SM | 1.8 | 3.0 | 59.0 | 0.0601 |
- Next: Sterling Pure Silver Alloy Wires Electrical Silver Coated Copper Wire
- Previous: Electrical Silver Coated Copper Wire Silver Aluminum Alloy Wire
Contact us
Similar Or Related
-
10X1.5mm2 Flame Retardant Copper Tape Screen Steel Tape Armored PVC Sheathed Control Cable 0.6/1kV
-
0.3/0.5kV 4X4mm2 Copper Wire Braiding PVC Insulation Low Voltage Control Power Cable
-
24X2.5mm2 XLPE Insulated Steel Tape Armoured Control/Instrumentation Cable IEC 60502-1
-
Low Voltage Single Core Power Cable 1X300 mm2 N2XCH CU/XLPE/CWS/LSF 0.6/1kV