Electric Wire Cable Overhead AAAC Aluminium Alloy Conductor

Electric Wire Cable Overhead AAAC Aluminium Alloy Conductor

Electric Wire Cable Overhead AAAC Aluminium Alloy Conductor

aaac

Bare

Stranded

Overhead

Aluminum

Bare

Bare

Round Wire

Overhead

ISO9001, CCC

BV

Rmjt

AAAC Conductor

Aluminum 6201,6101,1120

ASTM, IEC,BS,as,DIN…

transmission Line

China

ISO

RMJT

Wooden Drum

ASTM BS GB IEC DIN

China

7614900000

Product Description
Electric Wire Cable Overhead AAAC Aluminium Alloy Conductor

1.Application

Used as bare overhead conductor for primary and secondary distribution. Designed for utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics.

(1).AAAC conductors are extensively used for overhead distribution and transmission lines adjacent to ocean coastlines where there can be a problem of corrosion in the steel of an ACSR construction.
(2).The aluminum alloy conductors are used in replace of single-layer ACSR conductors to reduce power loss in overhead distribution and transmission lines,when replacing the aluminum conductor steel reinforced , the AAAC can save 5-8% of the construction cost.

(3)AAAC referred to have higher strength but lower conductivity than pure aluminum. Being lighter, alloy conductors can sometimes be used to replace the conventional ACSR.

2.Standard:
ASTM B399, BS EN50183 ,BS 3242,DIN 48201,IEC 61089

3.Specification

All Aluminium Alloy Conductors(AAAC) ASTM B 399
AREA Stranding Wire Dia. Approx.
overall diameter
Weight Nominal
Breaking Load
Nom. DC resistance
at 20 Deg.
Nominal Actual
AWGorMCM (mm2) (mm) (mm) (kg/km) (kN) (ohm/km)
6 13.3 7 1.554 4.67 37 4.22 2.5199
4 21.15 7 1.961 5.89 58 6.71 1.5824
2 33.63 7 2.474 7.42 93 10.68 0.9942
1/0 53.48 7 3.119 9.36 148 16.97 0.6256
2/0 67.42 7 3.503 10.51 186 20.52 0.4959
3/0 85.03 7 3.932 11.8 234 25.86 0.3936
4/0 107.23 7 4.417 13.26 296 32.63 0.3119
250 126.66 19 2.913 14.57 349 38.93 0.2642
300 152.1 19 3.193 15.97 419 46.77 0.2199
350 177.35 19 3.447 17.24 489 52.25 0.1887
400 202.71 19 3.686 18.43 559 59.74 0.1650
450 228 19 3.909 19.55 629 67.19 0.1467
500 253.35 19 4.12 20.6 698 74.64 0.1321
550 278.6 37 3.096 21.67 768 83.80 0.1202
600 303.8 37 3.233 22.63 838 91.38 0.1102
650 329.25 37 3.366 23.56 908 97.94 0.1016
700 354.55 37 3.493 24.45 978 102.20 0.0944
750 380.2 37 3.617 25.32 1049 109.60 0.0880
800 405.15 37 3.734 26.14 1117 116.80 0.0826
900 456.16 37 3.962 27.73 1258 131.50 0.0733
1000 506.71 37 4.176 29.23 1399 146.10 0.0660
6201 All Aluminum Alloy Conductor ASTM B399
Code Name Area Size&Stranding
of ACSR with
equal diameter
No. and
diameter
Overall
diameter
Weight Nominal
breaking
load
Nominal Actual
MCM mm2 AWG or MCM mm mm kg/km kN
AKRON 30.58 15.48 6 7/1.68 5.04 42.7 4.92
ALTON 48.69 24.71 4 7/2.12 6.35 68 7.84
AMES 77.47 39.22 2 7/2.67 8.02 108 12.45
AZUSA 123.3 62.38 1/0 7/3.37 10.11 172 18.97
ANAHEIM 155.4 78.65 2/0 7/3.78 11.35 217 23.93
AMHERST 195.7 99.22 3/0 7/4.25 12.75 273 30.18
ALLIANCE 246.9 125.1 4/0 7/4.77 14.31 345 38.05
BUTTE 312.8 158.6 266.8 19/3.26 16.3 437 48.76
CANTON 394.5 199.9 336.4 19/3.66 18.3 551 58.91
CAIRO 465.4 235.8 397.5 19/3.98 19.88 650 69.48
DARIEN 559.5 283.5 477 19/4.36 21.79 781 83.52
ELGIN 652.4 330.6 556.5 19/4.71 23.54 911 97.42
FLINT 740.8 375.3 636 37/3.59 25.16 1035 108.21
GREELEY 927.2 469.8 795 37/4.02 28.14 1295 135.47
AAAC (Characteristics of A2 Conductors) IEC 61089
Code number Area Number of wires Diameter Linear mass Rated strength D.C resistance
Wire Cond
mm2 mm mm kg/km kN Ohm/km
16 18.4 7 1.83 5.49 50.4 5.43 1.7896
25 28.8 7 2.29 6.86 78.7 8.49 1.1453
40 46 7 2.89 8.68 125.9 13.58 0.7158
63 72.5 7 3.63 10.9 198.3 21.39 0.4545
100 115 19 2.7 13.9 316.3 33.95 0.2877
125 144 19 3.1 15.5 395.4 42.44 0.2302
160 184 19 3.51 17.6 506.1 54.32 0.1798
200 230 19 3.93 19.6 632.7 67.91 0.1439
250 288 19 4.39 22 790.8 84.88 0.1151
315 363 37 3.53 24.7 998.9 106.95 0.0916
400 460 37 3.98 27.9 1268.4 135.81 0.0721
450 518 37 4.22 29.6 1426.9 152.79 0.0641
500 575 37 4.45 31.2 1585.5 169.76 0.0577
560 645 61 3.67 33 1778.4 190.14 0.0516
630 725 61 3.89 35 2000.7 213.9 0.0458
710 817 61 4.13 37.2 2254.8 241.07 0.0407
800 921 61 4.38 39.5 2540.6 271.62 0.0361
900 1036 91 3.81 41.8 2861.1 305.68 0.0321
1000 1151 91 4.01 44.1 3179 339.53 0.0289
1120 1289 91 4.25 46.7 3560.5 380.27 0.0258
1250 1439 91 4.49 49.4 3973.7 424.41 0.0231

4.Packing
Packing in wooden drums,steel wooden drums or as customer’s requirement.

5.Customer Visit
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win establish relationship!

6.Production process:
AAAC conductor producing process is drawing stranding and cabling,our factory possess 2 subsidiaries,Zhulin factory is professional bare conductor workshop with 20 production line.

7.Certificate
As first rank of the cable supplier in China, we have obtained CE, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.

8.About us:
People’s Cable Group Co., Ltd. was founded in 2007, located in Zhengzhou Gongyi economic development zone. Our company has 2 factories (Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters.

9.Contacts
Vivian Wong
T: 86-371-55367868 | M: 86-18339931106

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.