Duplex Service Drop Cable ABC Cable 6AWG Shepherd

Duplex Service Drop Cable ABC Cable 6AWG Shepherd

Duplex Service Drop Cable ABC Cable 6AWG Shepherd

ABC cable

Jinyuan

Jklyj

ISO, CCC

Aluminum

Round Wire

None

XLPE

DC & AC

Low and Medium Voltage Cable

Construction, Overhead, Industry

Aluminum and Steel

XLPE

HT

Wooden Drums

aluminum and steel

China

8544492100

Product Description

duplex service drop cable abc cable factory 6AWG shepherd

Applications
a. Duplex Service Drop
        Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum.
  b. Triplex Service Drop
        Application: To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene   insulation 90°C maximum for crosslinked insulation.
  c. Quadruplex Service Drop.
        Used to supply 3 phase power, usually from a polemounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at  conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors.

Standard
 ANSI/ICEA S-76-474,  NF C 33-209,  AS3560-1-2000,  IEC 60228, and ect.

Specification

Duplex service drop
Code Name Phase conductor Bare Neutral Message Nominal Weight ( kg/km ) Allowable Ampacity
Size & No.of wires Insulation Thick(mm) Nominal Diameter (mm) Size & No.of wires Rated Strength (kg) XLPE Aluminum ( A )
Bare OD
AAC
Pekingese 6-Solid 1.14 4.1 6.4 6-7 255 20.8 72.9 78
Collie 6-7 1.14 4.6 6.9 6-7 255 23.8 72.9 78
Cocker 6-7 1.52 4.6 7.7 6-7 255 32.7 72.9 78
Dachshund 4-Solid 1.14 5.2 7.5 6-7 400 26.8 114.6 103
Spaniel 4-7 1.14 5.9 8.2 6-7 400 29.8 116.1 103
Cairn 4-7 1.52 5.9 8.9 6-7 400 40.2 116.1 103
Doberman 2-7 1.14 7.4 9.7 2-7 612 38.7 184.5 136
Airedale 1-19 1.52 8.4 11.5 1-7 56.5 233.6 158
Basset 1/0-7 1.52 9.3 12.4 1/0-7 903 64 294.7 182
Malemure 1/0-19 1.52 9.4 12.5 1/0-7 903 64 294.7 182
AAAC
Chihuahua 6-Solid 1.14 4.1 6.4 6-7 499 20.8 72.9 78
VIzsla 6-7 1.14 4.6 6.9 6-7 499 23.8 72.9 78
Harrier 4-Solid 1.14 5.2 7.5 4-7 798 26.8 116.1 103
Whippet 4-7 1.14 5.9 8.2 4-7 798 29.8 116.1 103
Schnauzer 2-7 1.14 7.4 9.7 2-7 1270 38.7 184.5 136
Afghan 1/0-7 1.52 9.3 12.4 1/0-7 2023 64 296.1 182
Hocler 1/0-19 1.52 9.4 12.5 1/0-7 2023 64 296.1 182
ACSR
Setter 6-Solid 1.14 4.1 6.4 6/6/01 540 20.8 72.9 78
Shepherd 6-7 1.14 4.6 6.9 6/6/01 540 23.8 72.9 78
Retriever 6-7 1.52 4.6 7.7 6/6/01 540 32.7 72.9 78
Eskimo 4-Solid 1.14 5.2 7.5 4/6/01 844 26.8 114.6 103
Terrier 4-7 1.14 5.9 8.2 4/6/01 844 29.8 116.1 103
Yorkshirc 4-7 1.52 5.9 8.9 4/6/01 844 40.2 116.1 103
Chow 2-7 1.14 7.4 9.7 2/6/01 1293 38.7 184.5 136
Labrador 1-19 1.52 8.4 11.5 1/6/01 1610 56.5 233.6 158
Bloodhound 1/0-7 1.52 9.3 12.4 1/0-6/1 1987 64 294.7 182
Bull 1/0-19 1.52 9.4 12.5 1/0-6/1 1987 64 294.7 182

 

DESCRIPTION INSULATED PHASE CONDUCTORS Average Insulation Thickness
Type Nominal cross-section area Wire Number in the conductor Max. resistance at 20 o C Average diameter of conductors Rated Strength
mm 2 Number Ohm/km Mini mm     Max. mm Mini KN mm
PHASE,
NEUTRAL,
and
PUBLIC
LIGHTING
16 7 1.910 4.6               5.1 1.9 1.2
25 7 1.200 5.8               6.3 3.0 1.4
35 7 0.868 6.8               7.3 1.6
50 7 0.641 7.9               8.4 1.6
70 12 0.443 9.7             10.2 1.8
95 19 0.320 11.0           12.0 1.8
120 19 0.253 12.0           13.1 1.8
150 19 0.206 13.9           15.0 1.7
PORTER 54.6 7 0.630 9.2               9.6 16.6 1.6
70 7 0.500 10.0           10.2 20.5 1.5
95 19 0.343 12.2           12.9 27.5 1.6