Duplex Service Drop 2X16sqmm 0.6/1kv XLPE Insulated ABC Cable

Duplex Service Drop 2X16sqmm 0.6/1kv XLPE Insulated ABC Cable

Duplex Service Drop 2X16sqmm 0.6/1kv XLPE Insulated ABC Cable

0.6/1KV XLPE insulated Electrical ABC cable

Insulated

Stranded

Overhead

Aluminum

XLPE/PE/PVC

XLPE

Round Wire

Overhead Cable

CE, CCC, RoHS

XLPE/PE/PVC

4

IEC/NFC33-209

10 Years

Black

Laser Type

Yes

Yes

Yes

Hongda

Wooden Drum

4CORE ABC cable

China, Henan

8544492100

Product Description

Application

Primarily used for 120 volt overhead service applications such as street lighting,outdoor lighting,and temporary service for construction. To be used at voltage of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene(XLPE) insulated conductors.

 

Standard:

ASTM B230, B231, B232 and B-399 ,B498,ICEA S-76-474

Construction

The phase conductors are concentrically stranded compressed 1350-H19 aluminum and insulated polyethylene or crosslinked polyethylene(XLPE), The neutral messengers are concentrically stranded AAC, ACSR, or 6201 aluminum alloy.

 

Technical parameters:

Code Name Phase Conductor Bare Neutral Approx.Weight  
  Size Stranding Insulation Thickness Size   Stranding XLPE PE  
  AWG  – mil AWG   – lbs/1000ft  
AAC Neutral Messenger  
Pekingese 6 Solid 45 6 7/w 63.5 61.7  
Collie 6 7/w 45 6 7/w 66.8 63.1  
Dachshund 4 Solid 45 4 7/w 95.5 93.4  
Spaniel 4 7/w 45 4 7/w 100.5 95.4  
Doberman 2 7/w 45 2 7/w 152.7 145.7  
Malemute 1/0 19/w 60 1/0 7/w 242.6 234.2  
 6201 Alloy Neutral Messenger
Chihuahua 6 Solid 45 6 7/w 67.6 65.8  
Vizsla 6 7/w 45 6 7/w 70.9 67.2  
Harrier 4 Solid 45 4 7/w 102.0 99.9  
Code Name Phase Conductor Bare Neutral Approx.Weight  
  Size Stranding Insulation Thickness Size Stranding XLPE PE  
  AWG   mil AWG lbs/1000ft  
ACSR Neutral Messenger    
Setter 6 Solid 45 6 6/1 75.0 73.2  
Shepherd 6 7/w 45 6 6/1 78.3 74.6  
Eskimo 4 Solid 45 4 6/1 113.7 111.6  
Terrier 4 7/w 45 4 6/1 118.7 113.6  
Chow 2 7/w 45 2 6/1 181.7 174.7  
Bull 1/0 19/w 60 1/0 6/1 288.7 280.3  
 6201 Alloy Neutral Messenger
Whippet 4 7/w 45 4 7/w 107.0 101.9  
Schnauzer 2 7/w 45 2 7/w 163.3 156.2  
Heeler 1/0 19/w 60 1/0 7/w 259.2 250.8  

Note:

(1)Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

(2)Conductor temperature of 90°C for XLPE, 75°C for PE; ambient temperatures of 40°C; emissivity 0.9;
2ft./sec/wind in sun.

 
Specific Parameters
Type
Designation
Rated Voltage
No.of cores
Nominal cross section (mm²)
JKV
Copper conductor PVC insulated aerial cable
                 
 
 
 
 
0.6/1KV
 
 
 
 
1,2,4,3+k
16-240
JKLV
Aluminum conductor PVC insulated aerial cable
16-240
JKY
Copper conductor PE insulated aerial cable
16-240
JKLY
Aluminum conductor PE insulated aerial cable
16-240
JKYJ
Copper conductor XLPE insulated aerialcable
16-240
JKLYJ
Aluminum conductor XLPE insulated aerial cable
16-240
 

Low Voltage Aerial Bundled Cable/ Low Voltage ABC Cable

The basic construction is as follows:
3 power cores consisting of standard aluminium conductors, insulated withXLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)

The messenger conductor can be of galvanised steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.

To be used at cotages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75oC for polyethylene insulated conductors or 90oC for crossliked polyethylene(XLPE) insulated conductors.
 

Packaging&Delivery

Packaging Details:Wooden drums,steel wooden drums or as your requirement
Delivery Time:Normally within 10 days (detailly depend on the order quantity)

 Contact us

Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software. 
 Tel :+86 18339931106 

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.