Cy PVC Control Cable, 300/500 V, Flexible Cu/PVC/Petp/Tcwb/PVC (BS EN 50525-2-51)
Product Description
Application
Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or damp conditions indoors.
Standards
Generally to BS EN 50525-2-51, BS EN/IEC 60332-1
CONSTRUCTION
Conductor
Class 5 flexible copper conductor according to BS EN 60228
(previously BS 6360)
Insulation
PVC (Polyvinyl Chloride) Type TI2 according to BS EN 50363
Binding Tape
PET (Polyester Tape)
Screen
TCWB (Tinned Copper Wire Braid)
Sheath
PVC (Polyvinyl Chloride) Type TM2 according to BS EN 50363
CHARACTERISTICS
Voltage Rating (Uo/U)
300/500V
Temperature Rating
Fixed: -30°C to +80°C
Flexed: -5°C to +70°C
Minimum Bending Radius
Fixed: 6 x overall diameter
Flexed: 15 x overall diameter
NO. OF CORES | NOMINAL CROSS SECTIONAL AREA | NOMINAL OVERALL DIAMETER | NOMINAL WEIGHT |
mm² | mm | kg/km | |
2 | 0.5 | 5.7 | 35 |
2 | 0.75 | 6.1 | 45 |
2 | 1 | 6.3 | 57 |
2 | 1.5 | 7.3 | 69 |
2 | 2.5 | 8.7 | 107 |
3 | 0.5 | 6 | 48 |
3 | 0.75 | 6.4 | 63 |
3 | 1 | 6.6 | 72 |
3 | 1.5 | 7.7 | 95 |
3 | 2.5 | 9.2 | 140 |
4 | 0.5 | 6.4 | 62 |
4 | 0.75 | 6.9 | 76 |
4 | 1 | 7.1 | 89 |
4 | 1.5 | 8.4 | 118 |
4 | 2.5 | 10 | 172 |
5 | 0.5 | 6.9 | 73 |
5 | 0.75 | 7.5 | 89 |
5 | 1 | 7.7 | 107 |
5 | 1.5 | 9.1 | 141 |
5 | 2.5 | 10.9 | 216 |
7 | 0.5 | 7.5 | 89 |
7 | 0.75 | 8.1 | 113 |
7 | 1 | 8.4 | 139 |
7 | 1.5 | 9.9 | 181 |
7 | 2.5 | 11.9 | 283 |
12 | 0.5 | 9.6 | 141 |
12 | 0.75 | 10.4 | 181 |
12 | 1 | 10.8 | 230 |
12 | 1.5 | 12.9 | 307 |
18 | 0.75 | 12.1 | 274 |
18 | 1 | 12.6 | 331 |
- Next: H05V-R, Electric Wire, 300/500 V, Cu/PVC Insulated Cable (HD 21.3)