CPE Sheath Rubber Mining Cable / Epr Insulated Cable

CPE Sheath Rubber Mining Cable / Epr Insulated Cable

CPE Sheath Rubber Mining Cable / Epr Insulated Cable

Rubber cable

Construction, Industrial

Low and Medium Voltage Cable

DC & AC

XLPE

PVC

Round Wire

Bare Copper Wire

ISO, CCC

Icea S-75-381/NEMA Wc 58, ASTM B-3

Yifang

Steel Drum

4AWG TO 500MCM

China

8544492100

Product Description

TYPE MP-GC XLPE INSULATED PVC SHEATH MINING CABLE 5-25 kV 4AWG TO 500MCM

APPLICATIONS

 

Suitable for use as follows:
• Use in stationary, horizontal, HV mine power, distribution circuits, for permanent or
semi-portable applications with power transmission in deep mines, surface mines,
open pits, tunnels, in conduit or duct, suitable for direct burial in wet or dry locations.
For vertical drop requirements consult with factory application specialist.

 

CONSTRUCTION

• Conductors: Bare, soft drawn, annealed copper per ASTM B-3, compact stranded
per ASTM B-496.
• Strand Shield: Extruded semi-conducting compound.
• Insulation: Flame resistant (90°C) Cross-Linked Polyethylene (XLP) ICEA S-75-381/
NEMA WC-58.
• Insulation Shield: Extruded semi-conducting compound, bare copper tape
(0.003") helically applied.
• Color Code: Black, White, Red nylon tracer tape applied between the insulation
semi-conductive layer and the copper tape shield.
• Ground Wires: Uninsulated, soft drawn, annealed, compact stranded, bare copper
per ASTM B-496, B-8 and B-33.
• Ground Check: Soft drawn, annealed, compact stranded, bare copper with yellow
EPR insulation.
• Cabling: Three shielded conductors are assembled in a helical configuration with two
uninsulated ground wires, one yellow insulated ground check and non-wicking fillers
as needed. A woven nylon polyester reinforcement binder is served over the entire
assembly for increased stability.
• Reinforcement: A woven nylon polyester reinforcement binder is applied over the
completed assembly for added core stability.
• Jacket: Black flame retardant (90°C) Polyvinyl Chloride (PVC) per ICEA S-75-381/
NEMA WC-58. Available in optional colors.

 

STANDARDS AND REFERENCES

• Meets or exceeds ICEA requirements as applicable for ICEA S-75-381/NEMA WC 58, ASTM B-3

• Meets Safty Certificate of Approval for Mining Products

 

 

BENEFITS

• Excellent resistance to oil, water, solvents, corrosives, sunlight, aging, cuts, tears and abrasions
• Resistant to most oils and chemicals, good cut, tear and abrasion resistance
• MP-GC is suitable for all horizontal mine power distribution, messenger assisted high line transmission
and direct burial in wet or dry locations.
• Jacket will have permanent marking via indent printed legend

 

WEIGHTS AND MEASUREMENTS

 

POWER CONDUCTORS GROUNDING CONDS. GROUND CHECK NOM. O.D. AMPACITY 40°C AMBIENT TEM
SIZE STRANDS INSULATION SIZE STRANDS
5KV
4 7 2.3 8 7 8 33.53 122
2 7 2.3 6 7 8 36.83 159
1 19 2.3 5 7 8 38.86 184
1/0 19 2.3 4 7 8 41.40 211
2/0 19 2.3 3 7 8 44.20 243
4/0 19 2.3 1 19 8 50.80 321
250 37 2.3 1/0 19 8 54.10 355
350 37 2.3 2/0 19 8 59.69 435
500 37 2.3 4/0 19 8 67.06 536
8KV
4 7 3.0 8 7 8 36.32 122
2 7 3.0 6 7 8 39.37 159
1 19 3.0 5 7 8 41.91 184
1/0 19 3.0 4 7 8 44.45 211
2/0 19 3.0 3 7 8 47.75 243
4/0 19 3.0 1 19 8 53.85 321
250 37 3.0 1/0 19 8 57.15 355
350 37 3.0 2/0 19 8 62.48 435
500 37 3.0 4/0 19 8 69.85 536

 

 

POWER CONDUCTORS GROUNDING CONDS. GROUND CHECK NOM. O.D. AMPACITY 40°C AMBIENT TEM
SIZE STRANDS INSULATION SIZE STRANDS
15KV
2 7 4.45 6 7 8 47.75 159
1 19 4.45 5 7 8 50.29 184
1/0 19 4.45 4 7 8 52.07 211
2/0 19 4.45 3 7 8 54.61 243
4/0 19 4.45 1 19 8 60.96 321
250 37 4.45 1/0 19 8 63.50 355
350 37 4.45 2/0 19 8 69.85 435
500 37 4.45 4/0 19 8 78.74 536
25KV
2 7 6.6 6 7 8 59.44 159
1 19 6.6 5 7 8 61.47 184
1/0 19 6.6 4 7 8 63.75 211
2/0 19 6.6 3 7 8 66.04 243
4/0 19 6.6 1 19 8 73.41 321
250 37 6.6 1/0 19 8 75.95 355
350 37 6.6 2/0 19 8 81.53 435
500 37 6.6 4/0 19 8 88.90 536

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.