Covered Line Wire Alloy 6201-T81 Aluminum Conductor

Covered Line Wire Alloy 6201-T81 Aluminum Conductor

Covered Line Wire Alloy 6201-T81 Aluminum Conductor

Insulated

Stranded

Overhead

Aluminum

LDPE/HDPE/XLPE

XLPE

Round Wire

Overhead

ISO9001, CE, UL, CCC, RoHS, VDE

Yifang

Covered Line Wire AAC Aluminum Conductor

Yifang

Wooden Drum, Wooden Iron Drum, Steel Drum, etc

GB, IEC, BS, ASTM, etc.

China

7614900000

Product Description

Applications
Covered Line Wire is used primarily for overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.

Construction
Conductors are aluminum alloy 1350-H19, 6201-181, or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene (HD) or crosslinked polyethylene (XLP).

Standards

  • ASTM B-230 – Aluminum 1350-H19 Wire for Electrical Purposes.
  • ASTM B-231 – Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR).
  • ASTM B-1248 – Polyethylene Plastics Molding and Extrusion Materials.
  • ASTM C-8.35 – Specifications for Weather-Resistant Polethylene-Covered Wire and Cable.
  • ICEAS-61-402
  • NEMA PUB NO. WC 5-1973 – Standards Publication Thermoplastic insulated Wire and Cable for the Transmission and Distribution of Electrical Energy.

Notes

  • The code words as given apply to conventional polyethylene line wire.
  • For 6201 aluminum conductors diameter equivalent to ACSR construction or 1350 aluminum equivalent.
  • Ampacity ratings based on 75 ºC conductor temperature, 25 ºC ambient temperature elevation – sea level. Emissivity 0.91 coefficient of absorption 0.95. Thermal reisitivity of covering -3ºC-Cm2/Watt-CM. Wind speed 2ft/sec in sun.
  • To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
Request Information Compare Items

Item #

Size
AWG or MCM

Strand

Insulation
Thickness
(mils)

Outside
Diameter

Rated
Breaking
Strength

Weight
Per
MFT
XLP

Weight
Per
MFT
Poly

Ampacity
XLP

Hornbeam 4 7/w 30 mls .310 Inches 1480 Lbs 62.1 Lbs 60.1 Lbs 145 Amps
Linden 2 7/w 45 mls .406 Inches 2520 Lbs 96.1 Lbs 93.3 Lbs 190 Amps
Oilnut 1/0 7/w 60 mls .518 Inches 4010 Lbs 166.1 Lbs 160.0 Lbs 250 Amps
Waterash 2/0 7/w 60 mls .567 Inches 4850 Lbs 203.3 Lbs 196.4 Lbs 290 Amps
Shellbark 3/0 7/w 60 mls .622 Inches 6110 Lbs 249.4 Lbs 241.4 Lbs 335 Amps
Planetree 4/0 7/w 60 mls .683 Inches 7700 Lbs 307.3 Lbs 298.1 Lbs 385 Amps

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.