Covered Line Wire Alloy 6201-T81 Aluminum Conductor
Covered Line Wire Alloy 6201-T81 Aluminum Conductor
Insulated
Stranded
Overhead
Aluminum
LDPE/HDPE/XLPE
XLPE
Round Wire
Overhead
ISO9001, CE, UL, CCC, RoHS, VDE
Yifang
Covered Line Wire AAC Aluminum Conductor
Yifang
Wooden Drum, Wooden Iron Drum, Steel Drum, etc
GB, IEC, BS, ASTM, etc.
China
7614900000
Product Description
Applications
Covered Line Wire is used primarily for overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.
Covered Line Wire is used primarily for overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.
Construction
Conductors are aluminum alloy 1350-H19, 6201-181, or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene (HD) or crosslinked polyethylene (XLP).
Standards
- ASTM B-230 – Aluminum 1350-H19 Wire for Electrical Purposes.
- ASTM B-231 – Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR).
- ASTM B-1248 – Polyethylene Plastics Molding and Extrusion Materials.
- ASTM C-8.35 – Specifications for Weather-Resistant Polethylene-Covered Wire and Cable.
- ICEAS-61-402
- NEMA PUB NO. WC 5-1973 – Standards Publication Thermoplastic insulated Wire and Cable for the Transmission and Distribution of Electrical Energy.
Notes
- The code words as given apply to conventional polyethylene line wire.
- For 6201 aluminum conductors diameter equivalent to ACSR construction or 1350 aluminum equivalent.
- Ampacity ratings based on 75 ºC conductor temperature, 25 ºC ambient temperature elevation – sea level. Emissivity 0.91 coefficient of absorption 0.95. Thermal reisitivity of covering -3ºC-Cm2/Watt-CM. Wind speed 2ft/sec in sun.
- To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
Request Information Compare Items
Item # |
Size
|
Strand |
Insulation
|
Outside
|
Rated
|
Weight
|
Weight
|
Ampacity
|
---|---|---|---|---|---|---|---|---|
Hornbeam | 4 | 7/w | 30 mls | .310 Inches | 1480 Lbs | 62.1 Lbs | 60.1 Lbs | 145 Amps |
Linden | 2 | 7/w | 45 mls | .406 Inches | 2520 Lbs | 96.1 Lbs | 93.3 Lbs | 190 Amps |
Oilnut | 1/0 | 7/w | 60 mls | .518 Inches | 4010 Lbs | 166.1 Lbs | 160.0 Lbs | 250 Amps |
Waterash | 2/0 | 7/w | 60 mls | .567 Inches | 4850 Lbs | 203.3 Lbs | 196.4 Lbs | 290 Amps |
Shellbark | 3/0 | 7/w | 60 mls | .622 Inches | 6110 Lbs | 249.4 Lbs | 241.4 Lbs | 335 Amps |
Planetree | 4/0 | 7/w | 60 mls | .683 Inches | 7700 Lbs | 307.3 Lbs | 298.1 Lbs | 385 Amps |
- Next: PVC Insulation Multi-Pairs Instrumantation Cable with Collective Screen
- Previous: Copper Wire and Tape Screening XLPE Power Cable