Covered Copper Nylon Jacket Field Telephone Cable Double Wire Twisted

Covered Copper Nylon Jacket Field Telephone Cable Double Wire Twisted

Quick Details

Covered Copper Nylon Jacket Field Telephone Cable Double Wire Twisted

Field Telephone Cable

Hongda

Covered Copper Nylon Jacket Field Telephone Cable

ISO, CCC, SGS

Tinned Wire

Stranded

Round Wire

Covered Copper Nylon Jacket Field Telephone Cable

PE

BC/CCS/CCA/TC/CU/CCAG

Local Communication Cable, Coaxial Cable, LAN Cable, Long Distance Symmetric Cable, RF Cable, Aerial Connections

UV Resistant PE

-10 C to +80 C

Hongda

500m/Roll, Other Customer Requirements

0.5mm2 to 0.8mm2

China

8544491100

Product Details

Covered copper Nylon Jacket Field Telephone Cable Double wire Twisted

The PE Drop Wire is used in telephone connectivity. The drop wire is available in oval shape to add in conductor field separation. These are two round solid copper covered steel wires that serve dually as conductors and strength members. It comes with good tensile strength, conductivity and elongation property.

The bonding of insulation with the conductor is controlled to assure that the full conductor strength is transferred to the wire support clamp. These wires are conductor resistant, insulation resistant and minimal breakage possibility. It does not get any burn in the first 60 seconds and lasts longer than usual drop wires.

Construction
 

7X0.28MM(3 Number of Zinc Covered Steel+4 Number of Tin Covered copper Strands)x2+2.3mmPolyethylene+Nylon+Double Wire (Twisted)

 

1. Thickness of insulation (Polyethylene) Minimum 0.35 mm
2. Thickness of Polumide Jacket (Nylon) 0.15 mm (Average)
3. Overall diameter of single conductor Maximum 2.30 mm
4. Breaking load for two wires conductor Minimum 72 Kg
5. Cutting load test 55 lb (Average)/25 Kg (Average)
6. DC Loop Resistance 151 Ohm/Km (at 20°C)
7. Insulation Resistance 2000 M Ohm/Km
8. Dielectric Strength Test 1000 V AC (Minimum)
9. Weight of Zinc Cover for each steel Strands Minimum 25 gm/Kg
10. Weight of Tin Covered for each steel Strands 8.75 – 24.8 gm/Kg
11. No. Of Twist/M 14 – 16 Nos. (Average)
12 Apparent Shape Double Wire (Twisted)
13 Color Black
14 Conductors (Physical Characteristics)  
  (a) Number of Strands 07 Nos 
  (b) Number of Tin Covered copper Strands 04 Nos 
  (c) Number of Zinc Covered Steel Strands 03 Nos 
  (d) Diameter of each Stands 0.28 mm ± 0.01 mm

7X0.25MM(4 Number of Zinc Covered Steel+3 Number of copper Strands)x2+2.15mm Polyethylene Double Wire (Twisted)

1 Single wire diameter 0.25mm
2 Number of copper Strands 3 Nos
3 Number of steel Strands 4 Nos
4 Thickness of insulation (Polyethylene) ≥ 0.35 mm
5 Overall diameter of single conductor ≤ 2.15 mm
6 Temperature -15ºC~55ºC
7 Cable length (roll) 500±5m
8 Breaking load for two wires conductor ≤ 490N
9 DC Loop Resistance ≤230 Ω/Km (at 20°C)
10 Insulation Resistance ≥50 M Ω/Km
11
Attenuation constant
≤1.9dB/km
12
Characteristic resistance
840Ω
13 Dielectric Strength Test 1000 V AC (Minimum)
14 Weight of TWISTED WIRE ≤14KG
15 No. Of Twist/M 14 – 16 Nos. (Average)
16 Apparent Shape Double Wire (Twisted)
17 Color Black

7X0.25MM(7 Number of Copper Covered Steel Strands)x2+1.95mm Polyethylene Double Wire (Twisted)

1 Single wire diameter 0.25mm
2 Number of copper covered steel Strands 7 Nos
3 Thickness of insulation (Polyethylene) ≥ 0.35 mm
4 Overall diameter of single conductor ≤ 1.95 mm
5 Cable wire diameter twisted ≤ 3.9mm
6 Temperature -45ºC~55ºC
7 Cable length (roll) 500±5m
8 Breaking load for two wires conductor ≤ 490N
9 DC Loop Resistance ≤300 Ω/Km (at 20°C)
10 Insulation Resistance ≥3000 M Ω/Km
11
Attenuation constant
≤1.8dB/km
12 Dielectric Strength Test 1000 V AC (Minimum)
13 Weight of TWISTED WIRE ≤ 10KG
14 No. Of Twist/M 14 – 16 Nos. (Average)
15 Apparent Shape Double Wire (Twisted)
16 Color Black

4X0.25MM(Aramid covered 4 Number of Tinned Copper Strands)x2+2.1mm Polyethylene Double Wire (Twisted)

1 Single wire diameter 0.25mm
2 Number of tinned copper Strands 4 Nos
3 Thickness of insulation (Polyethylene) ≥ 0.35 mm
4 Overall diameter of single conductor ≤ 2.1 mm
5 Cable wire diameter twisted ≤ 4.2 mm
6 Temperature -45ºC~55ºC
7 Cable length (roll) 500±5m
8 Breaking load for two wires conductor ≤ 490N
9 DC Loop Resistance ≤85 Ω/Km (at 20°C)
10 Insulation Resistance ≥3000 M Ω/Km
11
Attenuation constant
≤1.8dB/km
12 Dielectric Strength Test 1000 V AC (Minimum)
13 Weight of TWISTED WIRE ≤ 10KG
14 No. Of Twist/M 14 – 16 Nos. (Average)
15 Apparent Shape Double Wire (Twisted)
16 Color Black

Packing

  • 100m/roll,200m/roll,305m/roll,100yard/roll,200yard/roll,305yard/roll,other lengths according clinets requires
  • Inner packing:wooden reel,plastic drum,paper stool
  • Outer packing:carton box,pull out box pallet available
  • Other packing is available according to the client’s requirements

OUR SERVICE:
1. Any inquiries will be replied within 24 hours.

2. Professional manufacturer, 12 years manufacturing experience.   

3. OEM/ODM available

4. High quality, reasonable and competitive price, fast lead time.

5. Good after-Sale Service.

1) All products will have been strictly Quality Checked in house before packing
2) All products will be well packed before shipping.

6. Faster delivery:
Sample order in stock, and 5-7 days for bulk production.

Please contact us for technical support with the right cable selection for your power distribution projects and to discuss your maintenance or project specific requirements. We provide tailored solutions for this cable range which include storage, cutting to length, and 2 days collection as standard.

Any problem and inquiry pls contact with Vivian Yuan.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.