Copper Wire XLPE Power Cable

Copper Wire XLPE Power Cable

Copper Wire XLPE Power Cable

XLPE CABLE

Jinyuan

ISO9001, CCC

Mine

Round Wire

PVC

PVC

Copper

Underground

Stranded

Insulated

IEC 60502

100000mm2

25

Black, Red

Aluminium or Copper

15 Days

Jinyuan

CCC ISO

Round Wire

7-19

Jinyuan

Wood Drum or Steel- Wood Drum

Power Cable

China

8544601200

Product Description

Copper Wire XLPE Power Cable

Application range
 Power and control cable for fixed installation in the following applications:
For indoor and outdoor use
Burial without additional, suitable underground protection according to VDE standard HD 603/VDE 0276-603 – Part 3-G (point 4)
governing PVC cables for direct burial: normal minimum installation depth 0.6 m, but at least 0.8 m under roads
In concrete with a temperature below the maximum cable operating temperature of +70 °C according to the VDE standard HD
603/VDE 0276-603 – Part 3-G (point 4) governing PVC cables for direct burial
In water: no longer than 2 weeks at a time, maximum submersion depth 10 metres, only in static water/bodies of water without
shipping traffic
 
 Product Make-up
Aluminium conductor
Abbreviations "re", "rm", "se", "sm": r = round conductor form; s = sectorial conductor form; e = single-wire conductor (wire =
conductor)/braided conductor class 1 according to IEC 60228/VDE 0295 for fixed, static applications; m = multi-wire
conductor/braided conductor class 2 according to IEC 60228/VDE 0295 for fixed, static applications, but with a slightly lower
minimum bending factor
Core insulation: Based on PVC
Filling compound over the core assembly
PVC-based outer sheath
Norm references / Approvals
HD 603/VDE 0276-603
Product features
Flame-retardant according IEC 60332-1-2
Maximum tensile strain for aluminium conductors during installation is 30 N/mm² according to HD 603/VDE 0276-603: Part 1
Appendix A.4.12 and Part 3-G point 4
Current rating according to HD 603/VDE 0276-603, Part 3-G, Table 14 (buried at +20 °C ground temperature according to HD
603/VDE 0276-603, Part 3-G, point 5) for routing underground and Table 15 (in the air at an air temperature of +30 °C
according to HD 603/VDE 0276-603, Part 3-G, point 5) when used outdoors; but always taking into consideration
corrections/reductions to the current rating that may be necessary according to VDE 0298-4, and VDE 0298-4 (also refer to the
catalogue appendix T12) for installation in and on buildings
 
Technical Data
Core identification code: According to VDE 0293-308 (table T9)
Classification: ETIM 5.0 Class-ID: EC000057
ETIM 5.0 Class-Description: Low voltage power cable
Conductor stranding: Single-wire
Minimum bending radius: Fixed installation: 12 x outer diameter
Nominal voltage: Uo/U: 0.6/1.0 kV
Test voltage: 4000 V
Temperature range: During installation: -5°C to +50°C
Fixed installation: -30°C to +70°C
 

Number of cores and mm² per
conductor
Outer diameter (mm) Alu index (kg/km) Weight (kg/km)
4*35re 29 406 1170
4*50se 30 580 1305
4*70se 35 812 1730
4*95se 9 1102 2205
4*120se 2 1392 2655
4*150se 46 1740 3150
4*185se 51 2146 3925
4*240se 60 2784 4880

 

   