Copper Wire Cable XLPE Insulated Underground Alarm Cable Price

Copper Wire Cable XLPE Insulated Underground Alarm Cable Price

Copper Wire Cable XLPE Insulated Underground Alarm Cable Price

4x50sq. mm

Construction, Underground, Industrial, Power Station, Telecommunication

Low and Medium Voltage Cable

DC Cable

XLPE

PVC

Round Wire

Bare Copper Wire

ISO, CCC, VDE

YJLV22

Jytop

Max. DC Resistance @ 20 Degree 0.387 Ohm/Km

Max. DC Resistance @ 20 Degree 4.61 Ohm/Km

Max. DC Resistance @ 20 Degree 3.08 Ohm/Km

Max. DC Resistance @ 20 Degree 1.83 Ohm/Km

Max. DC Resistance @ 20 Degree 1.15 Ohm/Km

JYTOP

Packed in Reels

4x50sq. mm

Zhengzhou, China

8544492100

Product Description

Copper wire cable XLPE Insulated underground alarm cable price

Suitable for rated voltage not more than 600V,rated temperature not more than 500 degree celsius
Nominal Voltage:600V
Nominal Temperature:200°c or 450°c
Conductor:Nickel Copper
Insulation:Mica tape with lapping
Jacket: Fiberglass
Use: For kinds of electric installation for metallurgy,hot work,Petroleum,chemical industry, natural gas,kerosene,etc. special environments
Property:Suitable for rated voltage not more than 600V,rated temperature not more than 500°c
Installation condition:Fixed
Fire performance:Not fuse below 800°c with 90 minites
Opposite temperature: 65% can use under bending and fire,no toxic and harmful gases

PVC insulated fire resistant cable can be made according to BS, VDE, ASTM, AS,CSA standards according to customer’s request.

PVC insulated Fire resistant cables come in a variety of types and standards. All are comprehensively tested to British Standard to ensure they meet their design criteria.

The FP Cables range of fire resistant cables contains cables for most fire applications from a fire resistant alternative to standard cable for use in metal conduits and trunking, to more specialist cable for fire alarms, fire detection circuits and emergency lighting. A good example of this is FP200 Gold® – a hard skin cable, incorporating damage resistant Insudite insulated cores.

product data table(0.6/1KV)
no. of cores ×nominal cross-section area
(mm²)
approx. overall diameter
(mm)
current rating
at 25 degree celsius
(A)
approx. weight of cable
(kg/km)
laid in the air laid under ground
2×1.5 10.5 19 25 129
2×2.5 11.3 26 34 158
2×4 13 35 44 221
2×6 14 44 56 274
2×16 18.8 80 100 519
3×2.5 11.9 22 29 194
3×1.5 11 17 22 154
3×4 13.8 29 38 274
3×6 14.9 37 47 348
3×10 17.6 52 65 529
3×16 19.9 68 85 740
3×25 23.7 91 110 1058
3×35 26.1 112 134 1382
3×50 26.4 133 159 1760
3×70 29.8 171 199 2364
3×95 33.8 209 237 3158
3×120 36.7 242 271 3921
3×185 45.6 329 346 5952
4×4 14.9 30 38 339
4×6 16.1 38 48 436
4×10 19.3 53 66 669
4×16 21.8 70 86 953
5×4 16.2 31 39 403
5×6 17.5 39 49 520
5×10 21 54 67 811
3×35+1×16 27.1 113 134 1719
3×70+1×35 36.1 180 203 2809
3×95+1×50 40.2 221 242 3768
3×120+1×70 45.1 258 276 4748
3×185+1×95 53.9 343 349 7127
3×25+2×16 26.8 94 110 1536
3×35+2×16 28.9 115 132 1872
3×50+2×25 34.2 141 157 2596
3×120+2×70 49 259 266 6124
3×150+2×70 53.7 294 298 7113
3×185+2×95 60 340 338 9046
3×240+2×120 67.5 407 395 11558

Note: RE= round conductor RM = stranded conductor SM=sectional conductor

Cable size Conductor type Nominal thickness of XLPE insulation(mm) Nominal thickness of PVC or PE sheath(mm) Approx. cable overall diameter (mm) Max. D.C resistance @ 20 0 C (Ω/km)
4×1.5mm 2 RE or RM 0.7 1.8 10.5 12.1
4×2.5mm 2 RE or RM 0.7 1.8 11.5 7.41
4x4mm 2 RE or RM 0.7 1.8 12.6 4.61
4x6mm 2 RE or RM 0.7 1.8 13.8 3.08
4x10mm 2 RM 0.7 1.8 16.9 1.83
4x16mm 2 RM 0.7 1.8 19.5 1.15
4x25mm 2 SM 0.9 1.8 21.3 0.727
4x35mm 2 SM 0.9 1.8 23.4 0.524
4x50mm 2 SM 1.0 1.9 26.8 0.387
4x70mm 2 SM 1.1 2.0 30.6 0.268
4x95mm 2 SM 1.1 2.1 34.9 0.193
4x120mm 2 SM 1.2 2.3 38.4 0.153
4x150mm 2 SM 1.4 2.4 42.5 0.124
4x185mm 2 SM 1.6 2.6 47.4 0.0991
4x240mm 2 SM 1.7 2.8 53.4 0.0754
4x300mm 2 SM 1.8 3.0 59.0 0.0601

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.