Copper Quadruplex Cable Duplex Triplex Service Drop Aerial Cable Hippa

Copper Quadruplex Cable Duplex Triplex Service Drop Aerial Cable Hippa

Copper Quadruplex Cable Duplex Triplex Service Drop Aerial Cable Hippa

Service Drop Aerial Cable

Construction, Overhead, Industrial

Low and Medium Voltage Cable

AC Cable

PVC

No Sheath

Round Wire

Aluminum Conductor

ISO, CCC

ABC Aerial Cable

OEM

OEM

Wooden Drum

2.5~400sqmm

China(Mainland)

8544492100

Product Description

Application
Used to supply power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. Also suitable for installations for street lighting, security lights, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75 ºC for polyethylene insulated conductors and 90 ºC for crosslinked polyethylene (XLP) insulated conductors.

Specifications
Meets or exceeds the following ASTM specifications:

  • B-1 Hard-Drawn Copper Wire.
  • B-3 Soft or Annealed Copper Wire.
  • B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft.

Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and crosslinked polyethylene insulated conductors.

Construction
Conductors are concentrically stranded compressed soft copper insulated with either crosslinked polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.

Notes:

  • Code words for XLP insulated products are formed by adding ""XLP"" to the conventional polyethylene code words above (e.g.-Theta/XLP).
  • Ampacity figures for black insulation only. Based on conductor temperature of 75 ºC for polyethylene insulated conductors, 90 ºC for XLP insulated conductors, ambient temperature of 40 ºC 2 ft./sec. wind in sun.

 

Dimensions – nominal cross-section Number of cores External diameter of rope External diameter of rope Conductor resistance at 20 °C Insulation thickness Diameter with insulation Diameter with insulation
    min. max. max. approx. min. max.
mm²   mm mm Ω/km mm mm mm
Phase conductor
16 7 4,6 5,1 1,910 1,2 7,0 7,8
25 7 5,8 6,3 1,200 1,4 8,6 9,4
35 7 6,8 7,3 0,868 1,6 10,0 10,9
50 7 7,9 8,4 0,641 1,6 11,1 12,0
70 19 9,7 10,2 0,443 1,8 13,3 14,2
Neutral conductor
71,5 AlMg 1 7 10,2 10,6 0,470 1,8   14,6
70 AlMgSi 7 10,0 10,2 0,500 1,6 12,9 13,6

Packing shipping

  


Any problem and inquiry pls contact with Tina
Phone number: +86-18339931106