Copper PVC Insulation PVC Sheath Round Parallel Wire
Copper PVC Insulation PVC Sheath Round Parallel Wire
BVVB 2*0.75 2*1.0 2*10 3*1.5 3*10
Insulated
Stranded
Indoor
Copper
PVC
ISO9001, CE, UL, CCC
300/500V, 450/750V
JINSHUI OEM
100 Meters Per Roll
CE ROHS CCC
China
8544492100
Product Description
Electrical wire instruction:
Name:
Single Core PVC insulation copper wire
Structure:
Conduct—Copper / Aluminum / Copper clad aluminum
Insulation—PVC
Size:
According to Standard / Sample / Price requirement.
Detailed Product Description
PVC Wire is used for lighting, electronic equipment, instument and communication equipment with rated voltage 450/750V or 300/500V.
Specification:
1. The rated voltage of the wires should equal to or higher then the rated voltage of the system when wires are used at AC system. If the wires are used at DC system, the rated voltage of system should lower then 1.5 times as high as rated voltage of cable and wires. The working voltage of the system could be 1.1 times as high as the rated voltage of the cable.
2. The long term working temperature should lower then 70oC. The working temperature of BV-90 should lower then 90oC. And the laying temperature should higher then 0oC.
3. The curve diameter of the wire should longer than 8 times of the diameter of the outer diameter of cable and wires if their outer diameter is 25 mm or above. If the diameter of cable and wires is above 25 mm, the curve diameter should be at least 12 times of the outer diameter of the cable and wires.
Name:
Single Core PVC insulation copper wire
Structure:
Conduct—Copper / Aluminum / Copper clad aluminum
Insulation—PVC
Size:
According to Standard / Sample / Price requirement.
Detailed Product Description
PVC Wire is used for lighting, electronic equipment, instument and communication equipment with rated voltage 450/750V or 300/500V.
Specification:
1. The rated voltage of the wires should equal to or higher then the rated voltage of the system when wires are used at AC system. If the wires are used at DC system, the rated voltage of system should lower then 1.5 times as high as rated voltage of cable and wires. The working voltage of the system could be 1.1 times as high as the rated voltage of the cable.
2. The long term working temperature should lower then 70oC. The working temperature of BV-90 should lower then 90oC. And the laying temperature should higher then 0oC.
3. The curve diameter of the wire should longer than 8 times of the diameter of the outer diameter of cable and wires if their outer diameter is 25 mm or above. If the diameter of cable and wires is above 25 mm, the curve diameter should be at least 12 times of the outer diameter of the cable and wires.
Nominal section (mm 2 )
|
Number diameter of core (mm)
|
Average dia (mm)
|
Reference weight(kg/km)
|
Conductor resistance at 20 ( Ω /km) | |||
Min
|
Max
|
Copper
|
Aluminium
|
Copper
|
aluminium
|
||
1.5(A)
|
1/1.38
|
2.6
|
3.2
|
20.3
|
–
|
12.1
|
–
|
1.5(B)
|
7/0.52
|
2.7
|
3.3
|
21.6
|
–
|
12.1
|
–
|
2.5(A)
|
1/1.78
|
3.2
|
3.9
|
31.6
|
17
|
7.41
|
12.1
|
2.5(B)
|
7/0.68
|
3.3
|
4.0
|
34.8
|
–
|
7.41
|
–
|
4(A)
|
1/2.25
|
3.6
|
4.4
|
47.1
|
22
|
4.61
|
7.41
|
4(B)
|
7/0.85
|
3.8
|
4.6
|
50.3
|
–
|
4.61
|
–
|
6(A)
|
1/2.76
|
4.1
|
5.0
|
50.3
|
29
|
3.08
|
4.61
|
6(B)
|
7/1.04
|
4.3
|
5.2
|
71.2
|
–
|
3.08
|
–
|
10
|
7/1.35
|
5.6
|
6.7
|
119
|
62
|
1.83
|
3.08
|
16
|
7/1.70
|
6.4
|
7.8
|
179
|
78
|
1.15
|
1.91
|
25
|
7/2.14
|
8.1
|
9.7
|
281
|
118
|
0.727
|
1.20
|
35
|
7/2.52
|
9.0
|
10.9
|
381
|
156
|
0.524
|
0.868
|
50
|
19/1.78
|
10.6
|
12.8
|
521
|
215
|
0.387
|
0.641
|
70
|
19/2.14
|
12.1
|
14.6
|
734
|
282
|
0.268
|
0.443
|
95
|
19/2.52
|
14.1
|
17.1
|
962
|
385
|
0.193
|
0.320
|
120
|
37/2.03
|
15.6
|
18.8
|
1180
|
431
|
0.153
|
0.253
|
150
|
37/2.25
|
17.3
|
20.9
|
1470
|
539
|
0.124
|
0.206
|
185
|
37/2.52
|
19.3
|
23.3
|
1810
|
666
|
0.0991
|
0.164 |