Copper/Aluminium/Soft Copper Conductor XLPE PE Insulated Aerial Cable Electric Aerial Cable

Copper/Aluminium/Soft Copper Conductor XLPE PE Insulated Aerial Cable Electric Aerial Cable

Copper/Aluminium/Soft Copper Conductor XLPE PE Insulated Aerial Cable Electric Aerial Cable

JKYJ JKTRYJ JKLYJ JKY JKTRY JKLY

Insulated

Stranded

Overhead

Copper

No

XLPE

Round Wire

ISO9001, CCC

Gdyg

GDYG

Wooden Reel, Steel Reel

0.5-630 mm2

Guangdong, China

Product Description


Construction Sketch 

 

1.Conductor
2.Conductor screen (no light type)
3.Weather-resistant XLPE(PE) insulation

Standards
It is manufactured in accordance with GB/T14049-2008, "Aerial cable with rated voltage 10kv" 

Size

Type  Number of cores Rated Voltage 
KV
10 35
Nominal Cross-section mm2
JKYJ 1 10-300 50-300
YKTRYJ
JKLYJ 3 25-300
JKLGYJ
JKY 1 10-300
JKTRY
JKLY
JKLYJ/Q
JKLGYJ/Q
JKLY/Q

Type and Application

Type  Name Application 
JKYJ Copper conductor XLPE insulated aerial cable  Used for fixed installation. For soft copper cable, it is used for the leading wires of transformer.
JKTRYJ Soft copper conductor XLPE insulated aerial cable 
JKLYJ Aluminum conductor XLPE insulated aerial cable   
JKLGYJ Steel core aluminum conductor XLPE insulated aerial cable  Cable should keep some distance from trees when it is being laid, and it can touch the trees frequently when it is on operation. 
JKY Copper conductor PE insulated aerial cable 
JKTRY Soft copper conductor PE insulated aerial cable 
JKLY Aluminum conductor PE insulated aerial cable  
JKLYJ/Q Aluminum conductor thin XLPE insulated light aerial cable Used for fixed installation. 
JKLGYJ/Q Steel core aluminum conductor XLPE insulated light aerial cable   
JKLY/Q Aluminum conductor thin PE insulated light aerial cable  Cable should keep some distance from trees when it is being laid, but it can touch the trees frequently when it is on operation. 

 

Features
1.The rated voltage (U/Um) is 10kv. These cables can be used in the system where the single phase earting fault duration is not more than 1 min, the maximum fault duration is not more than 8h each time and total fault duration are not more than 125h one year.
2.The installation temperature of cable shall be not lower -20ºC
3.The maximum short circuit (maximum duration is not more than 5s) temperature:
-XLPE insulated cable: 250ºC
-HDPE insulated cable: 150ºC
4.The minimum installated bended radius shall be not less than:
-Single core cable–20(D+d)
-Multicore cable–15(D+d)
(D–diameter of cable, mm; d–Nominal diameter of conductor)