Control XLPE Electrical PVC Rubber Copper ABC Insulated AAAC/AAC Cable

Control XLPE Electrical PVC Rubber Copper ABC Insulated AAAC/AAC Cable

Control XLPE Electrical PVC Rubber Copper ABC Insulated AAAC/AAC Cable

Insulated

Stranded

Overhead, Underground

Copper

XLPE

Round Wire

Flame Retardant

ISO9001, CE, CCC

Jinshui

JINSHUI

Drum

CE, ISO, CCC

Zhegnzhou Henan

Product Description

1. Standard

The control cable can be produced according to the standard GB9330-1988,IEC,DIN,BS,and the factory can also manufacture the cables in accordance with other standards.

2.Scope of Application

The control cable are suitable for the wiring of electrical controlling equipments and instrument,monitoring and controlling return circuit,electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.

3.Type& Specification

4.Service Conditions

(1)The long-time working temperature of conductor of PVC insulated cable is 70oC

The long-time working temperature of conductor of XLPE insulated cable is 90oC

(1) The temperature for laying the cables can not be lower than 0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D

Type Name Section Area(mm2) No. of Core Application Site
KVV Copper Conductor,PVC Insulated and Sheathed Control Cable 0.75 1.0 1.5 2.5 2-16 Permanent installation indoors,in cable ditches or pipes
4 6 2-14
10 2-10
KVVP Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded Control Cable 0.75 1.0 1.5 2.5 2-61 Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6 2-14
10 2-10
KVVP2 Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable 0.75 1.0 1.5 2.5 4-10 Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6 7-61
10 4-10
KVV22 Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable 0.75 1.0 1.5 2.5 7-61 Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force
4 6 4-14
10 4-14
KVVR Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable 0.5-2.5 4-61 Installation indoors where flexibility and movability are required
KVVRP Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable 0.5 0.75 1.0 4-61 Installation indoors where flexibility shielding and movability are required
1.5 2.5 4-48
KYJV Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable 0.75 1.0 1.5 2.5 2-16 Permanent installation indoors,in cable ditches or pipes
4 6 2-14
10 2-10
KYJVP Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable 0.75 1.0 1.5 2.5 2-61 Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6 2-14
10 2-10
KYJV22 Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable 0.75 1.0 1.5 2.5 7-61 Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force
4 6 4-14
10 4-10
KYJVP2 Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable 0.75 1.0 1.5 2.5 7-61 Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6 4-14
10 4-10
KYJVR Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable 0.5-2.5 4-61 Installation indoors where flexibility and movability are required
KYJVRP Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable 0.5 0.75 1.0 4-61
1.5 2.5 4-48 Installation indoors where flexibility shielding and movability are required