PVC/XLPE Insulated Low Voltage Power Cable

Standard:

IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer’s request.

The Rated Voltage(kv):

1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35 
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 – 26/35

Application:

Power cable are most suitable for direct burial or for installation on trays or ducts,  Where there is
a risk of mechanical damage, armoured cables should be used.
 

TYPE

NAME

Main Application

CU core

AL core

 

 

YJV/YJY

YJLV/YJLY

XLPE insulated,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Unable to bear external mechanical forces,
but bear the traction force during laid

YJV22/YJV23

YJLV22/YJLV23

XLPE insulated,steel tape armored,
PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Able to bear external mechanical forces,
but unable to bear large pulling force

YJV32/YJV33

YJLV32/YJLV33

XLPE insulated,thin steel wire armored,
PVC/PE sheathed power cable

For laying in shaft,water underground will large difference of level.
Able to bear external mechanical forces and moderate pulling force

YJV42/YJV43

YJLV42/YJLV43

XLPE insulated,thick steel wire armored,
PVC/PE sheathed power cable

For laying in water and seabed.
Able to bear positive pressure and pulling force

Number of cores:

1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.

Nominal Section 
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800

Features:

1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.

5).Application: for laying indoor, tunnel, canal and underground. 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Alum Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
1×4 2.3 0.7 1 0.8 1.8 10.9
1×6 2.8 0.7 1 0.8 1.8 11.4
1×10 3.6 0.7 1 0.8 1.8 12.2
1×16 4.5 0.7 1 0.8 1.8 13.1
1×25 5.6 0.9 1 0.8 1.8 14.6
1×35 6.7 0.9 1 1.25 1.8 16.6
1×50 8 1 1 1.25 1.8 18.1
1×70 9.4 1.1 1 1.25 1.8 19.7
1×95 11 1.1 1 1.6 1.8 22
1×120 12.4 1.2 1 1.6 1.8 23.6
1×150 13.8 1.4 1 1.6 1.8 25.4
1×185 15.3 1.6 1 1.6 1.8 27.4
1×240 17.5 1.7 1 1.6 1.9 29.9
1×300 19.5 1.8 1 2 2 33.1
1×400 22.6 2 1.2 2 2.2 37.3
1×500 25.2 2.2 1.2 2 2.3 40.5

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
2×1.5 1.4 0.7 1 0.8 1.8 12.8
2×2.5 1.8 0.7 1 0.8 1.8 13.6
2×4 2.3 0.7 1 0.8 1.8 14.6
2×6 2.8 0.7 1 1.25 1.8 16.5
2×10 3.6 0.7 1 1.25 1.8 18.1
2×16 4.5 0.7 1 1.25 1.8 19.9
2×25 5.6 0.9 1 1.6 1.8 23.6
2×35 6.7 0.9 1 1.6 1.8 25.8
2×50 8 1 1 1.6 1.9 29
2×70 9.4 1.1 1 2 2 .3 3.2
2×95 11 1.1 1.2 2.1 3 7.1
2×120 12.4 1.2 1.2 2 2.3 40.5
2×150 13.8 1.4 1.2 2.5 2.4 45.4
2×185 15.3 1.6 1.4 2.5 20.6 49.9
2×240 17.5 1.7 1.4 2.5 20.7 55.1
2×300 19.5 1.8 1.6 2.5 20.9 60.2
2×400 22.6 2 1.6 2.5 30.1 67.7

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
3×1.5 1.4 0.7 1 0.8 1.8 13.2
3×2.5 1.8 0.7 1 0.8 1.8 14.1
3×4 2.3 0.7 1 0.8 1.8 15.2
3×6 2.8 0.7 1 1.25 1.8 17.1
3×10 3.6 0.7 1 1.25 1.8 18.9
3×16 4.5 0.7 1 1.25 1.8 20.8
3×25 5.6 0.9 1 1.6 1.8 24.7
3×35 6.7 0.9 1 1.6 1.8 27.2
3×50 8 1 1 1.6 1.9 30.6
3×70 9.4 1.1 1 2 2.1 35.2
3×95 11 1.1 1.2 2 2.2 39.3
3×120 12.4 1.2 1.2 2 2.3 43
3×150 13.8 1.4 1.4 2.5 2.5 48.6
3×185 15.3 1.6 1.4 2.5 2.7 53
3×240 17.5 1.7 1.4 2.5 2.8 58.5
3×300 19.5 1.8 1.6 2.5 3 64
3×400 22.6 2 1.6 3.15 3.3 73.5

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1 1.6 1.8 22.7
3x 25/16 5.6 4.5 0.9 0.7 1 1.6 1.8 26.5
3x 35/16 6.7 4.5 0.9 0.7 1 1.6 1.9 29
3x 50/25 8 5.6 1 0.9 1 1.6 2.1 33
3x 70/35 9.4 6.7 1.1 0.9 1.2 2 2.2 38
3x 95/50 11 8 1.1 1 1.2 2 2.3 42.4
3×120/70 12.4 9.4 1.2 1.1 1.2 2 2.5 48
3×150/70 13.8 9.4 1.4 1.1 1.4 2.5 2.7 52
3×185/95 15.3 11 1.6 1.1 1.4 2.5 2.8 57.2
3×240/120 17.5 12.4 1.7 1.2 1.6 2.5 3.1 64
3×300/150 19.5 13.8 1.8 1.4 1.6 2.5 3.2 69.8

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
4×1.5 1.4 0.7 1 0.8 1.8 14
4×2.5 1.8 0.7 1 0.8 1.8 14.9
4×4 2.3 0.7 1 1.25 1.8 17
4×6 2.8 0.7 1 1.25 1.8 18.2
4×10 3.6 0.7 1 1.25 1.8 20.2
4×16 4.5 0.7 1 1.6 1.8 23
4×25 5.6 0.9 1 1.6 1.8 26.7
4×35 6.7 0.9 1 1.6 1.9 29.5
4×50 8 1 1 2 2.1 34.2
4×70 9.4 1.1 1.2 2 2.2 38.8
4×95 11 1.1 1.2 2 2.3 42.9
4×120 12.4 1.2 1.4 2.5 2.5 48.6
4×150 13.8 1.4 1.4 2.5 2.7 53.2
4×185 15.3 1.6 1.4 2.5 2.8 58.1
4×240 17.5 1.7 1.6 2.5 3.1 64.8
4×300 19.5 1.8 1.6 2.5 3.2 70.4
4×400 22.6 2 1.8 3.15 3.6 81.3

Production progress

Packaging
Packing Details  : Packing in wooden drum, iron-wooden drum or as customer’s requirement.
Delivery Details : 15-25 days after place an order.

About US
People’s Cable Group Co., Ltd. was founded in 2007, located in Zhengzhou Gongyi economic development zone. Our company has 2 factories (Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters. 

Customer Visit
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you.
With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!

Contact us

 

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.